, 16 ) Note 2) 90 + 40 (n 4) 2 95 + 40 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 15 + 40 n (n = 2, 4, 6, 8 ) Note 1) (n = 4, 8, 12, 16 ) Note 2) 2 (Different surfaces, Same surface) 1 60 65 70 D-M9V D-M9WV (n 2) 2 10 55 55 + 30 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 60 + 30 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 65 + 30 (n 4) 2 70 + 30 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 10 + 30 n (n = 2, 4, 6
Tightening torque (Nm) M22 x 1.5 Mounting nut width across flats (mm) Bore size (mm) Mounting nut thread 20 25 32 40 26 45 M24 x 1.5 32 60 M30 x 1.5 38 85 M33 x 1.5 41 110 2.
60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 CS1 23.5 23.5 C76 Bracket Combinations C85 Bracket Combinations Available Refer to table together with combination drawings.
Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.
fluid outlet 0.6 60 Pressure [MPa] 0.5 50 Lifting head [m] Usable flow rate range 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow[L/min] Fig. 8-11 Pump capacity(HRL300-A-20 CH1) 8.5.4 HRL-A-20CH2 0.6 60 0.5 50 Lifting head [m] Pressure [MPa] 0.4 40 Usable flow rate range Circulating fluid outlet 0.3 30 0.2 20 Chiller display
Fig. 9-22 Cooling Capacity (HRL100/200-W-40-T2 CH2) HRL Series 9.4 Cooling Capacity 9-19 HRX-OM-X037 Chapter 9 Documents 9.5 Pump Capacity 9.5.1 HRL100-A/W-40 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig.
60 B A 50 H 50 W(kg) A/H W(kg) 40 40 30 30 20 20 10 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 LECPA V(mm/s) V(mm/s) LES40 Horizontal Transfer LES40 Vertical Transfer B 60 (2) Servo motor (24VDC) Ball screw drive 60 B A 50 H 50 A/H W(kg) W(kg) 40 40 30 30 20 20 10 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 V(mm/s) V(mm/s) LEFS16A LEFS25A Model Stroke [
BAND TEMP SP READY TIME TEMP PV TEMP READY display/output TEMP READY not display/not output Figure 8-7 BAND/READY Function Examples of Setting TEMP SP: 20C BAND: 2C READY TIME: 60 sec. RDY is displayed on the operation touch panel 60 sec. after TEMP PV value becomes 18C to start output by communication. Necessary condition is that TEMP PV value after 60-sec. is 20+/-2.0C or less.
CS1 Trunnion (mm) Stroke range Bore (mm) TV TT TS TR TH TF B TDe8 TE Front Rear 0.025 0.047 0.025 0.047 0.032 0.059 0.032 0.059 0.032 0.059 0.032 0.059 20 25 32 40 50 63 3.2 3.2 4.5 4.5 6 8 28 33 40 49 60 74 39 43 54.5 65.5 80 98 25 30 35 40 50 60 5.5 5.5 6.6 6.6 9 11 Up to 200 Up to 200 8 10 12 14 16 18 35.8 39.8 49.4 58.4 72.4 90.4 38 45.5 54 63.5 79 96 10 10 10 10 20 20 Up to 300 Up to
70 60 70 Gripping point L (mm) Gripping point L (mm) MHR2-30/MDHR2-30 MHR2-30/MDHR2-30 80 80 Pressure 0.6 MPa 0.6 MPa Pressure 70 70 F F 0.5 MPa 0.5 MPa Gripping force (N) Gripping force (N) 60 60 50 50 0.4 MPa 0.4 MPa 40 40 0.3 MPa 0.3 MPa 30 30 0.2 MPa 0.2 MPa 20 20 10 10 0 10 30 50 0 10 30 50 70 90 90 70 Gripping point L (mm) Gripping point L (mm) 12-5-7 8 Series MHR2/MDHR2 Construction
Model Model Model Port size R(PT) Effective area (mm2) Weight (g) Dimensions (mm) Weight Effective area Port size Model Dimensions (mm) R(PT) (mm2) (g) AN200-02 35 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 A B D A B D 1 4 1 4 AN202-02 35 16 64 22 19 33 84 28 24 47 95 34 24 AN300-03 60 3 8 AN302-03 60 3 8 AN402-04 90 1 2 AN400
0.5MPa 0.5MPa 60 60 Holding force (N) Holding force (N) 50 50 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 30 30 0.2MPa 0.2MPa 20 20 10 10 0 10 30 50 0 10 30 50 70 90 90 70 Holding point L (mm) Holding point L (mm) 2.3-6 Series MHR2/MDHR2 Construction MHR2 !
Hz 200 VAC, 50/60 Hz 24 VDC 12 VDC Other Nil SB None With 10 10 stations VF Note) When equipped with control unit, 1 or 2 stations are used for mounting.
(A) 4 (B) 2 Electrical entry 6 1 (P) 5 (R1) 3 (R2) G Coil voltage Lead wire length 0.6 m 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Lead wire length 1.5 m Grommet Body 5: Plug lead sub-plate H Function Nil Y R Standard type (1 W) Low wattage type (0.5 W) External pilot Seal (1) 0 1 Metal seal Rubber seal (2) Note 1) Applicable to
Symbol Rated pressure range and accuracy Part no. 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC With pressure sensor (0 to 101 kPa, accuracy 2% F.S.) With pressure sensor (0 to 101 kPa, accuracy 1% F.S.) With pressure sensor (100 to 100 kPa, accuracy 2% F.S.) With pressure sensor (100 to 100 kPa, accuracy 1% F.S.)
490 6 63 34 MXW25-200 142 275 155 225 60 540 6 88 59 -X MXW25-225 165 305 175 245 55 55 590 7 113 84 1 MXW25-250 187 335 200 275 60 67 640 7 138 109 1 Individual -X MXW25-275 210 360 225 300 65 80 690 7 163 134 1 MXW25-300 232 395 245 320 60 52 60 740 8 188 159 2 165 Series MXW Auto Switch Proper Mounting Position (Detection at Stroke End) Reed Auto Switch: D-A90 (V), D-A93 (V), D-A96
60 Material: Cast iron Material: Cast iron Unit: mm Part no.
-60 kPa -50 kPa -40 kPa -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa Lifting force (N) Lifting force (N) How to read the graph Example: Workpiece weight 1 kg (Lifting force: 9.8 N) : Conditions/Number of pads: 5 pcs.