Body size 30 and 40 now have a transparent bowl guard that offers 360 visibility, while completely protecting the bowl from the environment.? Accessories include a bracket, and float type auto drain. AFD MASS PRO. AFD MASS PRO 3/8 MODULAR (NPT). AIRLINE EQUIPMENT. AFD MASS PRO 3/8 MODULAR (NPT). 1.54323 lb. EC.
SMCs series AW, is a combination filter/regulator, minimizing space and piping by integrating 2 units into one. The element and bowl on the AW series is now one-piece, making element replacement easier. Bowls on size 30 and 40 are covered with a transparent bowl guard, completely protecting them from the environment, and making the inside visible from 360 degrees.
There is a maximum 46% reduction in size, reducing required maintenance space.? The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360 monitoring.??The modular design of the AF allows connection with other SMC air preparation equipment. The series is available in body size 20, 30 and 40. AF MASS PRO. AF MASS PRO 3/8 MODULAR (NPT). AIRLINE EQUIPMENT.
Body Size: 40, Pipe Thread: N (NPT), Port Size: 03 (3/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: S (Water Drop Removal Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))
Body Size: 30, Pipe Thread: N (NPT), Port Size: 03 (3/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))
Body Size: 30, Pipe Thread: N (NPT), Port Size: 03 (3/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: S (Water Drop Removal Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: CT (Integrated Display; Out 1: NPN; Out 2: (Analog 1 to 5 V) ⇔ Analog 1 to 5 V ; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: G (Remote Sensor Unit; Instantaneous Flow:
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: P (Stop Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: E (Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None), Lead Wire: N (without Lead Wire), Flow Switch Unit: J (Integrated Display; Instantaneous Flow: L/min; Accumulated Flow:
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: L2T (Integrated Display IO-Link Compatible; Out 1: IO-Link/Switch Output (N/P); Out 2: Switch Output (N/P) ; Temperature Sensor: Yes), Lead Wire: Q [with M12-M8 conversion Lead Wire (0.1m)], Flow Switch Unit
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SILENCER *LQA, AIRLINE EQUIPMENT, AN SILENCER, ED, AN 3/8INCH STANDARD (NPT), .00440 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, REGULATOR *LQA, AIRLINE EQUIPMENT, AR REGULATOR, ED, AR 3/8INCH STANDARD (NPT), 1.727 lb
Part Number Description: VALVE ASSY FOR ARM411 REG Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 117 Family Description: AR(PILOT) PILOT REGULATOR Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
Flow Switch Type: Integrated Display, Rated Flow Range: 2~16L/min, Return Unit: Flow Adjustment Valve + Stop Valve, Thread: NPT, Port Size: 3/8, Flow Switch Output: Integrated Display; Out 1: NPN; Out 2: (Analog 1 to 5 V) ⇔ Analog 1 to 5 V ; Temperature Sensor: Yes, Lead Wire: without Lead Wire, Flow Switch Unit: Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min); Accumulated Flow
Flow Switch Type: Integrated Display, Rated Flow Range: 2~16L/min, Return Unit: Stop Valve, Thread: NPT, Port Size: 3/8, Flow Switch Output: Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None, Lead Wire: without Lead Wire, Flow Switch Unit: Integrated Display; Instantaneous Flow: L/min; Accumulated Flow: L; Temp: °F
Size: 3/8, Model Combination: AF+AR, Port Size: 3/8, Size 31, Accessory: None, All Sizes, Pressure Relief Valve: Downstream Valve, Option: Metal Bowl w/Sight Glass, Size 31 & 41, Handle Orientation: -
Size: 3/8, Model Combination: AF+AR+AL, Port Size: 3/8, Size 31, Accessory: None, All Sizes, Pressure Relief Valve: Downstream Valve, Option: Metal Bowl w/Sight Glass, Size 31 & 41, Handle Orientation: Upward Handle
Size: 3/8, Model Combination: AF+AR, Port Size: 3/8, Size 31, Accessory: None, All Sizes, Pressure Relief Valve: Downstream Valve, Option: Metal Bowl w/Sight Glass, Size 31 & 41, Handle Orientation: Upward Handle
Size: 31 (3/8), Model Combination: B (AF+AR), Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41)
Size: 31 (3/8), Model Combination: B (AF+AR), Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41), Handle Orientation: A (Upward Handle)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com