SMC Corporation of America
Elite Part Number Search
Search Results "VV5K3-21-05-00T"

D-S79# D-S99# D-S99V# D-S7P# D-S9P# D-S9PV# D-T79#(C) D-T99# D-T99V# Sheath Outside diameter (mm) 3.4 Insulator Wires 3-wire (Brown, Blue, Black) 2-wire (Brown, Blue) Outside diameter (mm) 1.1 Cross section (mm2) 0.2 Conductor Wire diameter (mm) 0.08 Minimum bending radius (mm) (Reference value) 21 -19No.D-S-OMB0023-C Dimensions D-S791#/D-S7P1#/D-T791# D-S792#/D-S7P2#/D-T792# -20No.D-S-OMB0023

The manifold is extended by 21 mm per one station of the output block (power block) and 42.2 mm (SI unit 28.2 mm, bracket plate 14 mm), so please prepare a DIN rail taking into account the amount extended. -56No.EX-OMH0025-C (6)Water resistant cap Mount the water resistant cap in the unused ports of the Power block or Output block, (water resistant cap are delivered together with each unit

IN14 IN13 IN12 IN11 IN10 IN9 IN8 17 +2 IN23 IN22 IN21 IN20 IN19 IN18 IN17 IN16 +3 IN31 IN30 IN29 IN28 IN27 IN26 IN25 IN24 +0 IN7 IN6 IN5 IN4 IN3 IN2 IN1 IN0 +1 IN15 IN14 IN13 IN12 IN11 IN10 IN9 IN8 +2 IN23 IN22 IN21 IN20 IN19 IN18 IN17 IN16 18 +3 IN31 IN30 IN29 IN28 IN27 IN26 IN25 IN24 +4 R R R R R R R R +5 R R R R DI_CHK 1 SOLV 1 R R R: Reserved 1: Refer to the SI unit I/O data on page 21

Refer to page 28 for the configuration data map. (4) (1) (5) (2) (3) 21 No.EX-OMS0014-A I/O memory map I/O data Connection example Input data Input data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 0 IN15 IN14 IN13 IN12 IN11 IN10 IN9 IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN1 IN0 COM A 1 IN31 IN30 IN29 IN28 IN27 IN26 IN25 IN24 IN23 IN22 IN21 IN20 IN19 IN18 IN17 IN16 2 IN47 IN46 IN45 IN44 IN43 IN42

If the stain is persistent, wipe off with a cloth soaked in a dilute solution of neutral detergent and wrung out tightly, and then finish with a dry cloth. 15 No.VQC1000V-OMM0002-B 16 No.VQC1000V-OMM0001-B 17 No.VQC1000V-OMM0001-B 18 No.VQC1000V-OMM0001-B 19 No.VQC1000V-OMM0001-B 20 No.VQC1000V-OMM0001-B 21 No.VQC1000V-OMM0001-B 22 No.VQC1000V-OMM0001-B 23 No.VQC1000V-OMM0001-B 24 No.VQC1000V-OMM0001

No.EX-OMB0014-H PRODUCT NAME SI unit for CC-Link MODEL / Series / Product Number EX12#-SMJ1 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Definition and terminology 11 Mounting and Installation 12 Communication wiring 12 Power supply wiring 14 Settings 15 Maintenance 19 Troubleshooting 21 Specifications 31 Dimensions 32 -1No.EX-OMB0014

(Tightening torque: 0.6 Nm) L dimensions No. of output blocks / power blocks stations 1 2 3 4 5 6 7 8 L1 [mm] 83 104 125 146 167 188 209 230 L2 [mm] 72 93 114 135 156 177 198 219 L3 [mm] 67 88 109 130 151 172 193 214 : The above dimensions show an example when one unit of power block (width: 21 mm) is combined. -45No.EX##-OMO0019 Wiring Output wiring Connect output devices to the output connectors

(When power is supplied) 21 Configuration memory error. 22 System error. 23 Internal component has failed. -51No.EX-OML0011-C Parameter Setting Refer to the SI unit Operation Manual of protocol used. Unit type Unit symbol and displayed unit symbol of each unit are displayed.

Subindex (2) 0 W System Command N Refer to system command (P.19) 0x0002 (12) 0 R/W Device Access Lock Y Refer to device access lock (P.19) 0x000C 0x0010 (16) 0 R Vendor Name N SMC Corporation 0x0011 (17) 0 R Vendor Text N www.smcworld.com 0x0012 (18) 0 R Product Name N Example: D-MP025A 0x0013 (19) 0 R Product ID N Example: D-MP025A 0x0014 (20) 0 R Product Text N Actuator Position Sensor (21

Valve series Power consumption SY3000/5000/7000/9000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) SYJ3000/5000/7000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) VQZ1000/2000/3000 Standard: 1.0 W (approx. 42 mA) Low wattage: 0.5 W (approx. 21 mA) Refer to "Wiring of the branch cable and connector for connecting load" on

Valve series Power consumption SY3000/5000/7000/9000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) SYJ3000/5000/7000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) VQZ1000/2000/3000 Standard: 1.0 W (approx. 42 mA) Low wattage: 0.5 W (approx. 21 mA) Refer to "Wiring of the branch cable and connector for connecting load" on

Valve series Power consumption SY3000/5000/7000/9000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) SYJ3000/5000/7000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) VQZ1000/2000/3000 Standard: 1.0 W (approx. 42 mA) Low wattage: 0.5 W (approx. 21 mA) Refer to "Wiring of the branch cable and connector for connecting load" on

shows the stopped state.) 24 VDC 0 V Ry Reset switch for stop STOP switch Surge suppressor Ry Power supply cable(the 1st controller) Controller input power supply Ry 0V 0V 24V M24V C24V BK RLS Power supply cable(the 2nd controller) Controller input power supply 0V 0V 24V Ry M24V C24V BK RLS Power supply cable(the 3rd controller) Controller input power supply 0V 0V Ry M24V 24V C24V BK RLS 21

With surge and voltage suppressor (ZNR/surge absorption diode ) Note 4 ) Energization on A ( set ) side generates vacuum and energization on B ( reset ) side stops generation of vacuum. 21 - Doc. no. ZQ-OM00801-D How to Operate the Supply Valve of the Latching Type Latching type refers to a solenoid with self holding mechanism.

. -21- 13. When mounting the actuator using the body mounting reference plane, use the pin. And set the height of the pin to be 5mm or more because of R chamfering.(Recommended height:6mm) The surfaces of plates M and E on the ends of the product may slightly protrude from the body mounting reference plane. Besure to provide a clearance of 1 mm or more to avoid interference. 14.

. / AWG26 Nominal cross section of the conductor 0.15mm2 Insulator outside diameter / Identification colour 0.85mm / Red,Black,White,Green Sheath material Lead-free PVC O.D. 4mm 21 Doc. no.IZ*-OMX0012-B 7.

[ r ES] Response time All models 13 [ SUb] Sub display All models 14 [ inP] External input Model with external input function 15 [ Fr E] Setting of analogue output Model with analogue output function 16 [SAvE] Accumulated value hold All models 17 [ PoS] Orientation All models 18 [ Pr S] Supply pressure All models 19 [ dSP] Display OFF mode All models 20 [ P in] Security code All models 21

Use M12-4 pin socket (female) A cord. 19 - Refer to page 15 and 16 for procedures for changing the stopper bolt and switch positions and for top cover replacement instructions. 20 - 21 - 22 - p. 23 p. 24 p. 23 p. 24 p. 25 p. 26 23 - 24 - 25 - 26 - 27 - Refer to pages 32 and 33 for the weight of clamp arms.

Setting of special function Setting item Page Indication mode Reverse the indication mode. page 20 Indication unit (available with unit conversion function) page 21 NOTE When the default setting is changed, since the different setting item appears in order depending on how many times the button is pressed, confirm the item which needs to be set appears correctly and prevent undesired setting

ZL-OM00801 Digital Pressure Switch for Vacuum 21 - Doc. no. ZL-OM00801 Circuit Diagram ZL112 ZL112-K1*-D*** A ZL112-K2*-D*** A ZL212 22 - Doc. no. ZL-OM00801 Weight 23 - Doc. no. ZL-OM00801 Exhaust Characteristics and Flow Characteristics of Ejector 24 - Doc. no.