The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base. 0.58 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base. 0.57 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base. 0.57 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base. 0.62 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base circular connector type manifold for SV1000 valve, IP67 protection, Number of connectors: 26 pins, Maximum 20 stations available as standard, 6 ports available, Optional DIN rail mount 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base.
Supply Unit: W (Flow Adjustment Valve + Stop Valve), Rated Flow Range: 20 (2~16L/min), Thread: Rc, Port Size: 04 (1/2)
Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
No. w q Description ADC12 ADC12 e Note) Description Cap Body Motor Cam SCS13 r t C3604B 20137-1A Valve assembly y NBR S-16 O-ring 14-20-50 Note) Motor port no. in the case of 100 VAC: 812PG-100VAC
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Back Flow: w/o Backflow, Thread: N (NPT), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: J (Body Size 20: 1/8; Body Size 30 & 40: 1/4), Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: BDG (B + D + G), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: Standard, Attachment: TV1 (T + V1), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Drain Port: J (Drain Guide 1/8: Body Size 20; Drain Guide 1/4: Body Size 30, 40), Exhaust Mechanism: N (Non-relieving Type), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)]
Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Specifications Max. operating pressure (1) Fluid Compressed air 1.0 MPa 19 dB (A) JIS Symbol Noise reduction Ambient and fluid temperature 5 to 60C (2) Note 1) It
: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)