(in) D (D1): 1, Connection Screw Type M (M1): NPT (Male thread), Connection Screw Nominal M (M1): 1B(25A), Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PFA, Size of Body: 6

(in) D (D1): 1, Connection Screw Type M (M1): NPT (Male thread), Connection Screw Nominal M (M1): 1B(25A), Maximum Operating Temperature(°C): 150, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PVDF, Size of Body: 6

(in) D (D1): 1, Connection Screw Type M (M1): R, Connection Screw Nominal M (M1): 1B(25A), Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PFA, Size of Body: 6

(in) D (D1): 1, Connection Screw Type M (M1): NPT (Male thread), Connection Screw Nominal M (M1): 1B(25A), Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PFA, Size of Body: 6

(in) D (D1): 1, Connection Screw Type M (M1): NPT (Male thread), Connection Screw Nominal M (M1): 1B(25A), Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PFA, Size of Body: 6

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, "PRESSURE SWITCH

P Part in contact with fluid A part that comes into physical contact with the fluid. Pressure characteristics The amount of variation in the analogue output or display value when the supply pressure is changed.

AS1200-M5 AS1000 AS1001F 5. M2.5X4L 56mm 0.050.15Nm 10 6. MHY2-10D 4 MHY2-16D 3 MHY2-20D 2 MHY2-25D 2 (ON) (OFF) 7.

Switching of the valve is delayed. 1(P), 12 port is not supplied with pressure. Pressure is not within operating range. Inlet (1 port) pressure exceeds the operating pressure range.

As a reference valve, tightening torque is 0.4 to 0.5Nm. 2) M5 After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/6 to 1/4 turn. As a reference value, tightening torque is 1 to 1.5 Nm. Note) If tightened excessively, the thread of the product may break or the gasket may deform.

P Non-consumables parts (example: body, tube, covers) which are IN OUT worn out or damage cannot be replace as part of the maintenance request. E

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 14 Position for application of grease Table 9 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 28 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.14, ) Pay attention to the mounting direction of the seal.

(Spanner Nominal7) (SMC's special spanner P/N : 1129129 (Recommended) Hangs a spanner Element assembly Bowl assembly 19 AFM20-A Step 1 Hold the element with a spanner to rotate it counterclockwise and remove the element. See check item for referential tightening torque.

M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)]

Operating pressure: P (MPa) 3. Mass of total loads: Wo (kg) Wo = (Load mass: WA) + (Jig mass: WB) 4. Piston speed: v (mm/s) Calculate required output FA 9.8 x Wo FA = Operating pressure (MPa) Take next larger bore size than D 0.2 0.3 0.4 or more 0.4 0.5 0.6 Check Theoretical Output Fo Fo: Refer to Theoretical Output on page 413.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration