SMC Corporation of America
Elite Part Number Search
Search Results "VQ21A1-2YZB-C8-F"

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 3 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 5 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting)

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)

Model: 10S (Side Ported), SI Unit Specification: VB (CC-Link, 16 Outputs, M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 8 Stations, P, E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting w/DIN Rail)

Model: 10S (Side Ported), SI Unit Specification: VB (CC-Link, 16 Outputs, M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 2 Stations, P, E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting w/DIN Rail)

Series: 5 (10-SY5000), Actuation: 3 (3 Position, Closed Center), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: W3 (M8 Connector, w/Connector Cable, 1000mm), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: C8 (One-touch Fitting for ø8), Thread: Rc, Bracket: F2 (w/Side Bracket)

Series: 7 (10-SY7000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: L [L Plug Connector, w/Lead Wire, (300mm)], Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: C8 (One-touch Fitting for ø8), Thread: Rc, Bracket: F2 (w/Side Bracket)