25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1?s, Rise time 1ns660 g1/2, 3/4
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M and more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL PLUG-IN BASE MOUNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2D, VFS4000, 4.40924 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUG-IN BASE MNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2Q, VFS4000, 2.84151 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2G, VFS4000, 1.90294 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2D, VFS5000, 3.72982 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUGIN BASE MOUNT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2F, VFS5000, 2.79252 lb
10% or less)150 mA or lessIP650 to 50C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?
Please contact us for the latest version.sales@ocaire.com, VAC PAD (BELLOWS) W/BUFFER, VACUUM SERIES, ZP VACUUM PAD, TM, ZP PAD SIZE 2-8, .00000 lb
10 to 50C35 to 85%RH (with no condensation)1500 VAC for 1 min. between external terminals and FG10 M or more (500 VDC) between external terminals and FG10 to 150 Hz with a 0.35 mm amplitude or 49 m/s2 in each X, Y, Z direction for 2 hrs (De-energized)98 m/s2 in each X, Y, Z direction, 3 times (De-energized)CE marking, UL (CSA)120 g
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2I, VFS4000, 3.96832 lb
Please contact us for the latest version.sales@ocaire.com, CYL, R/BODY, D/ROD, VAC T/HOLE, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, LC, 32MM CM2 OTHERS (COMBO), .88184 lb
Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN W/3 VAC EJECTORS, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 2.75577 lb, 2.75577 lb
0.01 to 0.03C)Refer to performance chart.Approx. 0.8 gal (3 L)IN/OUT: Rc3/8Drain: Rc1/4 (with plug)Stainless steel 303, Stainless steel 304, EPDM, Ceramics, PPS glass 30%, Carbon, PE, Polyurethane50 to 95F (10 to 35C) (no condensation)Within 145 psi (1 MPa)2.1 to 2.6 gpm(8 to 10 L/min)IN/OUT: Rc3/8Stainless steel 303, Stainless steel 304Single-phase 200 to 220 VAC ?
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM EJECTOR, VACUUM SERIES, ZL112 MULTI-STAGE VAC
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized