Fixing hexagon socket head bolt 13 - 5) Mounting 1. Insert the spacers between the counter bores of the body. 2. Hold the product by L-brackets from both ends and tighten the hexagon socket head bolts. Tightening torque is 0.61 to 0.63Nm. The composition of parts to connect 3 ionizers is shown below.
Example : Enter LEFS16B-100B-R1 1 1.5m 3 3m for theLECP7**-LEFS16B-100 5 5m For body mounting For body mounting Specifications Item Specifications: Compatible motor Step motor (Servo/24 VDC) Power supply Note 1) Power voltage: 24 VDC 10% Note 2) [Including motor drive power, control power, stop, lock release] Number of positioning points 64 points Parallel input 11 inputs Parallel output 13
NA-080-INFLW 97 Power 73 54 30 15 Alarm 2 x 6 Mounting Holes Tube O.D. 1/4 In Port Alarm 50 73 54 30 15 Tube O.D. 1/4 Out Port 4 x M4 x 4 Mounting Holes LLD2A-02-Z07-X31 4 x M4 x 4 Mounting Holes (Includes controller & connectors) 20 Indicator 96 13 30 40 50 20 73 115.5 1/4HyperFlare with flow to 3000 ml/min 1/4HyperFlare 3/8Soundpipe 2000 2000 Minimum flow 2 ml/min 35 35 Measurement Range
Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) a = 3000 2000 m L1 0 10 20 30 Transfer load m (kg) L2 600 400 L2 (mm) Mer Rolling Yawing m 200 L2 Mer 10 20 30 0 Transfer load m (kg) m a = 1000 4000 a = 2000 L3 (mm) a = 3000 L3 2000 m Mey a 10 20 30 0 Transfer load m (kg) Refer to page 183 for deflection data. 158 13
When installing the products, allow access for maintenance and inspection. 13. Fluid pressure range Fluid pressure should be within the allowable pressure range. 14. Cannot be used as an emergency shut-off valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shut-off valve.
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 Symbol B A Inch sizes Basic size With reducer 03 05 07 11 13 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" Note 1) Applicable fittings: LQ2 Note 2) For details of the applicable tubing sizes, refer to page 945.
V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD PE Q S T U W MACM2 X114 68 74 76 10 27.4 12 34 X115 52 6 62 X116 50 4 30 46 60 64 22.5 MACM4 X114 86 90 90 72 78 32.5 50 19 32 20 33 X115 56 6 78 40 X116 54 4 40 6.6 12 19 17 18 M5 7 MACM6 X114 118 125 125 97 113 33.8 53 28 33.3 30 43 X115 59 6 98 60 X116 57 4 60 MACM10 X114 185 197 198 11 152 182 18 53.8 77 31 24 13
9, @0, @1, @2 2 Pilot body Aluminum alloy Silver baking finish 3 Bonnet Aluminum alloy Silver baking finish 4 Adjusting screw Stainless steel 5 Piston Brass 6 Piston rod Brass 7 Diaphragm assembly Aluminum alloy/Brass/NBR Chromated 8 Diaphragm NBR 9 Piston valve Brass/NBR 10 Piston valve Brass/NBR 11 Valve Brass/NBR 12 Adjusting spring Steel wire Zinc chromated 13 Valve spring Stainless steel
9, @0, @1, @2 2 Pilot body Aluminum alloy Silver baking finish 3 Bonnet Aluminum alloy Silver baking finish 4 Adjusting screw Stainless steel 5 Piston Brass 6 Piston rod Brass 7 Diaphragm assembly Aluminum alloy/Brass/NBR Chromated 8 Diaphragm NBR 9 Piston valve Brass/NBR 10 Piston valve Brass/NBR 11 Valve Brass/NBR 12 Adjusting spring Steel wire Zinc chromated 13 Valve spring Stainless steel
If a valve is placed immediately before the product, regardless of the operational state of the trigger, instantaneous air release may occur when compressed air is supplied. 13. If the supply pressure of compressed air is less than the product specification (0.05 MPa), the valve in the product may not operate correctly.
IZH IZH BEST DETECTING POSITION 50mm Sensor part 2 x 3.4 600 16.6 SMC 9 4.8 87.5 BEST DETECTING POSITION 50mm 13 8.8 0.5 6.5 7 (7.5) (175) 60 (12.3) BEST DETECTING POSITION 50mm 86 (55) (9.3) 21 519 IZH10 Series Names and Functions of Individual Parts LCD display Display of charged electricity Display of peak/bottom value Peak display P Bottom display b Measured Potential 20.0kV AUTO POWER-OFF
mounting) 5 Step Motor Controller JXCE1/91/P1/D1/L1 Series Dimensions JXCL1 35 4.5 For body mounting (Screw mounting) (11.5) 67 32.5 1.2 84.2 64.2 35 193.2 (When removing DIN rail) 187.3 (When locking DIN rail) 152.5 161 170 Mountable on DIN rail (35 mm) 77 17.5 4.5 For body mounting (Screw mounting) L 5.25 12.5 (Pitch) 7.5 5.5 (25) (35) 1.25 L Dimensions [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13
Fluorine coated KKA3 KKA4, 6, 7, 8, 9 KQG2 Plated with fluorine-contained material Fluorine coated Fluorine coated Fluorine coated Fluorine coated KKA3, 4, 6 KKA7, 8, 9 Equivalent to Stainless steel 304 Stainless steel 304 6 Plug valve spring KG KFG2 Equivalent to Stainless steel 304 Stainless steel 304 Stainless steel 304 Stainless steel 304 Stainless steel 304 10 Collar spring MS 11 12 13
Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. DM KDM Caution KB 1. Implement the tube piping in such a way that lateral load should not be applied on the ball bearings at the rotating part, otherwise it may adversely affect the life expectancy. A flexible polyurethane tube is recommended when lateral load is applied.
Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. H/DL L/LL KC Caution How to Use Caution KK Please do not attach metal rods or metal pipes. Metal rods or pipes cannot be secured and the fittings will shoot out. Also, if tubes are attached after metal rods or pipes have been attached, the tubes will not hold and may come loose.
Auto Switch Proper Mounting Position (Detection at stroke end) and Its Mounting Height Auto switch (Sensor section) 16 to 25 Indicator light A 17.5 B [mm] Auto switch model Bore size D-M9 J A B U 16 9.5 7 21 20 9.5 8.5 23.5 25 9.5 9 27 32 11 8 29 40 15 10.5 31 50 13 13.5 36 63 15.5 16.5 41.5 22 U 64.5 4 Auto switch (Amplifier section) 32 to 63 A 17.5 B U Note) Adjust the auto switch after
Failure to do so may cause a malfunction. 13. Do not use the product in places where it will be exposed to radiant heat. Such places are likely to cause a malfunction. 7. When the Fieldbus system is installed in machinery/equipment, provide adequate protection against noise by using noise filters, etc. Noise in signal lines may cause a malfunction. 8.
and Cover: Stainless steel 304, O-ring: NBR/FKM Element Lock Material Stainless steel 304 Construction Cylindrical type Step type Cylindrical type Step type Cylindrical type 5 m, 20 m 5 m, 20 m 5 m, 20 m 5 m 5 m Nominal filtration rating Differential pressure proof 0.6 MPa 1.1 l (when reservoir is set separately) 1.8 l (when reservoir is set separately) 6 l Reservoir tank capacity Weight 13
Data Related Products Contact for upper/lower temperature limit deviation alarm (open when alarm occurs) Upper/lower temperature limit deviation alarm common Unused Contact for output cut-off alarm (open when alarm occurs) Common for output cut-off alarm Unused 1 2 Connection Connection Connection 3-4 M Connection cable M Power cable 5 6 DC cable Signal cable Connector side IEC 60320 C-13
Flow Characteristics (Initial conditions) Refer to page 5-10-13 for Precautions on these products. 2504 to 2511 1 Model 0.5 A B D Dimensions (mm) Recommended flow (m3/min (ANR)) 2.2 or less 3.0 or less 4.0 or less 8.0 or less 10.0 or less 1.5 or less 1.5 or less Model Port size R Effective area (mm2) Weight (g) 0.2 Inlet pressure (MPa) Noise level (dB (A)) 1 4 2504-002 33.9 111 62 30 24 106