ZH-OM00401 Mounting of the standard bracket (ZH05 to 15DA) and adjustment of the vacuum (V) port (1) Align the recess of the standard bracket and the protrusion of the adapter.
Request message
Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-12HC1Power supply: 200/220(V)AC 10% Compatible
Output mode Hysteresis, Window comparator, Error output, Output OFF Switch operation Normal output, Reversed output Maximum load current 80 mA Switch output (SIO mode) Maximum applied voltage 30 V (NPN output) Internal voltage drop (Residual voltage) 1.5 V or less (at load current of 80 mA) Delay time*1 1.5 ms or less, variable from 0 to 60 s/0.01 s increments Hysteresis Hysteresis mode Variable
Note Accessory/Option CB-50H Petroleum, Water-glycol, Emulsion Differential pressure indicator CB-50H-V Phosphoric ester CB-51H Petroleum, Water-glycol, Emulsion Differential pressure indication switch (N.C. and N.O. common) CB-51H-V Phosphoric ester AG-12H Petroleum Blanking cap (for differential pressure indication part) AG-12H-W Water-glycol, Emulsion AG-12H-V Phosphoric ester 517 A FH100
Hydraulic fluid 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. Replacement Element Part No.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit specifications. 1080 A 1021-AW-B Filter Regulator Dimensions J J D M N T AW20-B 1021Bracket (Option) S U Panel fitting dimension F Y R Applicable tubing 6/4 W C Q V BB IN OUT OUT K H IN Z P2 Plate thickness 10-/21-AW20-B: Max. 3.5 Pressure gauge (Option) (Pressure gauge port size) B 2 x P1 (Port
Control equipment connected to the barrier must not use or generate more than 250 V. 2. Installation should be in accordance with Canadian Electrical Code or ANSI/ISA RP12.6 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations and the National Electrical Code or ANSI/NFPA 70. 3.
control equipment Air preparation equipment Relay, PLC A93 100 V Grommet Reed auto switch Yes 12 V 24 V 2-wire Note 1) Lead wire length symbols: 0.5 m Nil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ Note 2) Auto switches marked with are produced upon receipt of order.
Applicable load Lead wire length (m) Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Grommet Reed auto switch Yes 12 V 24 V 2-wire Note 1) Lead wire length symbols: 0.5 m Nil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.
200 V, Other voltage (Option) Coil rated voltage (V) VNB Pressure VNC2 24 V, Other voltage (Option) 15% to +10% of rated voltage External pilot air 0.1 + 0.25 x (Operating pressure) to 0.7 MPa Refer to Graph (1).
2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) Class B G C D, T S S L, Z Note) Be sure to read this before handling the products.
Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Tubing Series TRB Model Suitable for air and water piping in environments where sparks from spot welders, etc., may be a problem. Double layer design using flame resistant resin (equivalent to UL-94 Standard V-0) for outer layer.
This controller is designed with a separate control power supply (C 24 V) and motor power supply (M 24 V) to enable the aforementioned emergency stop circuitry to be configured.
If you do not plan to configure the emergency stop circuitry as described above, you can use the same power supply for the control power supply (C 24 V) and the motor power supply (M 24 V).
.· Single-phase: 100 V AC (50 Hz), 100/110 V AC (60 Hz), Single-phase: 110 V AC (50 Hz).· Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz), Single-phase: 220 V AC (50 Hz).
/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 2, /: /, 2nd Nominal Nozzle Size: ø1.0, 2nd Selection Supply Valve and Release Valve: N.C.
/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 1, /: None, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal Nozzle
/N.C., 2nd Selection Vacuum V Port: Vacuum, V Port: Ø1/4, 2nd Selection Quantity: 1, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal Nozzle Size: -, 4th Selection Supply Valve and Release Valve: -, 4th Selection Vacuum V Port: -, 4th Selection Quantity: -