Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 5 (24 VDC), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only), Port Size: 02 [1/4 (8A)], Thread Type: T (NPTF)
Stations: 12 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: B (Bottom Ported Rc1/4), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting)
Body Size: 40, Thread: Rc, Port: 06 (3/4), Option: Standard, Attachment: T (T spacer), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: DG (D + G), Attachment: T (T-spacer), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right->Left)
), Thread: T (NPTF), Option: F2 (Side Bracket)
Stations: 4 Stations, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 06B (3/4, Both Sides), PR Thread: T (NPTF)
Override: Non-locking Push Type, A,B Port Size: None, Mounting Option: K [Round head combination screw (Falling-out prevention type)], Wiring Specification: WO (w/o M12 Connector Cable), Port Location: Side Ported, Sub-plate Thread: T (NPTF)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: 01 (R 1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Emitter Cartridge Type: D (High Speed Static Neutralization Cartridge), High Voltage Cable Length: 3 (3m), One-touch Fitting: 7L (ΓΈ1/4" Elbow), Power Supply Cable Direction, Length: T (Entry Direction: Angled, Length: 5 m), Communication Cable Entry: T (Entry Direction: Angled, Length: 5 m), Nozzle Bracket: F (Angle Adjustment Bracket), DIN Rail Mounting Bracket: U (Controller: Included;
Protocol: M (CC-Link), Mounting: 8 (DIN Rail Mounting), Cable Connector: T (T-branch Type), Actuator: LEM, Type: H (Linear Guide Single Axis Type), Body Size: 25, Motor Mounting: LU (Symmetric, Bottom Mounting), Stroke: 500mm
Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: T (NPTF), Actuation Type: A (N.C., Normally Closed
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: T (NPTF), Actuation Type: B (N.O., Normally
Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: T (NPTF), Actuation Type: B (N.O., Normally Open
Please contact us for the latest version.sales@ocaire.com, NAME PLATE (VQ4000 T-TYPE), VALVE, VQ4000 NO SIZE RATING, .00000 lb
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KC, ZSE40/50/60 1/4 PORTED, 0.56689 lb
SMCs PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KC, ZSE40/50/60 1/4 PORTED, .55560 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift
SMC's VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
SMC's VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold