1(P), 3/5(R) port Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 VZ One-touch fitting for 4 C4 Port size 4(A), 2(B) port One-touch fitting for 6 C6 M5 x 0.8 VF One-touch fitting for 5/32" B3 One-touch fitting for 1/4" B7 Flow Characteristics VFR Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size 1(P), 5/3(R) port Manifold 2(B), 4(A) port C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VP4 VV5Z3-40
15, 20 25, 30 4 4, 6 4, 6, 8 4, 6, 8, 10 6 Single acting, spring return 8 10 Mass: Double Acting Made to Order (Refer to page 24 for details.)
(mm) Weight (g) A D M5 0.8 KGH04-M5 KGH04-01 14 13 9.5 8 17 22 4 4 2.4 9 16 5.6 1 4 KGH04-02 19.5 13.5 14 4 4 1 8 16 18 10 5.6 M5 0.8 KGH06-M5 KGH06-01 KGH06-02 14 3.4 16 14 15 18.5 17 11.5 18.5 22.5 23 4 10 12 14 1 8 1 4 6 13.1 13.1 17 3 8 KGH06-03 22 15.5 17 27 21 19 26 19 30 1 8 1 4 3 8 1 8 1 4 KGH08-01 KGH08-02 KGH08-03 KGH10-01 KGH10-02 24 20.5 15.5 26 27.5 28 26.5 22 30 33.5 14
Starting the Product . 4-1 4.1 Before Starting . 4-1 4.2 Preparation for Start . 4-2 4.2.1 Power supply . 4-2 4.2.2 Setting of circulating fluid temperature . 4-2 4.3 Preparation of circulating fluid . 4-3 4.4 Starting and Stopping . 4-6 4.4.1 Starting the product . 4-6 4.4.2 Stopping the product . 4-7 4.5 Check items after starting . 4-8 4.6 Adjustment of Circulating Fluid . 4-8 Chapter
error Alarm history 4 = No alarm (i) Request Example 1 Start code 2 ID 0 Controller ID: 1 3 1 4 Function code 0 Function code: "03h" 5 3 6 0 7 6 Start reading from Start address: D0600 address No. 8 0 9 0 Data 10 Number of 0 11 0 addresses to be Number of read addresses: 4 words read Note 1) 12 0 (Number of words) 13 4 Calculated 14 value Checksum(LRC) 15 Calculated value 16 End code CR
Detection port 4 One-touch fitting 6 One-touch fitting option F Supply port G1/8 (ISO1179-1) Piping Detection port G1/8 (ISO1179-1) Lead wire with connector M12 lead wire with 4 pin connector, 4 cores 4 5 m Lead wire M12 lead wire with 4 pin connector part, 4 cores, 4, Insulator O.D.: 1.14 mm Centralized lead wire part, 2 to 3 stations: 8 cores, 6, 5 m Centralized lead wire 4 to 6 stations
IO-Link DI DO StandardIO StandardIO 2 0x00 . 9-4 X0 X1 X2 X3 IO-Link 1 2 3 4 IO-Link 2 (I/Q) Bit 1 Bit 3 Bit 5 Bit 7 EX245-LA1 (EX245-LB1 0) 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DO 2 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DI() 9.5.
Shutdown . 4-1 4.1 Pre-check . 4-1 4.1.1 Installation condition . 4-1 4.1.2 Cable connection . 4-1 4.1.3 Installation of circulating fluid and facility water piping . 4-1 4.1.4 Operating signal from your system . 4-1 4.1.5 Check emergency off [EMO] switch . 4-1 4.2 Opening of Facility water Valve . 4-1 4.3 Supply of Circulating Fluid . 4-2 4.3.1 Preparation of circulating fluid . 4-2 4.3.2
5 6 7 8 n C8: 3(R) port C8: 1(P) port 9 For top ported 4 4 4 4 4 4 4 4 R 3 60 37 26 2 1 2 2 2 2 2 2 2 P 29.5 13 7.5 P = 11.5 58 43.5 2n-C3, C4, C6, M5 (4(A), 2(B) port) C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread L n Formula: L1 = 11.5n + 55.5, L2 = 11.5n + 73 n: Stations (Maximum 24 stations) Dimensions 24 331.5 349 375 385.5 23 320
Flow Characteristics Port size Manifold C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv Flow characteristics 1(P), 5/3(R) port 2(B), 4(A) port 1 4/2 (P A/B) 4/2 5/3 (A/B R) VV5Z5-21P-01 VV5Z5-21P-C6 VV5Z5-21P-C8 VZ523 1/4 1/4 1/4 1/8 C6 C8 2.1 1.4 1.8 0.36 0.32 0.37 0.55 0.36 0.50 2.3 2.1 2.1 0.26 0.24 0.20 0.54 0.50 0.50 Note) Value at manifold base mounted, 2 position single operating How
VNB1 -6A, 8A, 10A VNB2 -10A, 15A VNB3 -20A VNB4 -25A VNB5 -32A, 32F VNB5 4 -32A, 32F VNB6 -40A, 40F VNB6 4 -40A, -40F VNB7 -50A, 50F VNB7 4 -50A, 50F No.
0 HA GA 5H9 4 deep +0.030 0 A B NN-M6 X 1 thread 12 deep 6 1 26 5.1 9.5 10.5 10.5 A B 24 10.5 24 10.5 H (NN-1) X H G Cross section AA Cross section BB (mm) Model F 35 35 35 40 30 55 65 70 GA 16 16 16 16 51 61 109 159 KA NA 2 2 2 2 2 4 4 4 N 4 4 4 4 6 6 6 8 HA 40 40 40 50 30 70 70 70 G 16 16 16 16 21 26 39 19 H 40 40 40 50 30 35 35 35 NN 2 2 2 2 3 4 5 7 I 10 10 10 10 15 40 55 68 J 40 40 40
Table. 4-2 Overview of modules for the SI Unit Module Occupied bytes Allowable slot (Number / Name) Note Input Output Diagnostics type 1 4 bytes 1 / Diagnostics Refer to Section 5.1.1 Diagnostics type 1 shared 4 bytes 1 / Diagnostics Refer to Section 5.1.1 and Table 4-3 Diagnostics type 2 4 bytes 1 / Diagnostics Refer to Section 5.1.2 Diagnostics type 2 shared 4 bytes 1 / Diagnostics Refer
YY depth YL T-slot dimensions XAH7 depth XL b a c d X 0.02 X XAH7 e (mm) XB e 9.5 11 13.5 18.5 Bore size (mm) 32 40 50 63 d 3.5 4 4.5 7 c 5.5 5.5 7.5 10 b 10.5 10.5 13.5 17.8 a 6.5 6.5 8.5 11 XAH7 XC XL Section XX detail Section XX WB WA Z Section XX 4-MM depth ML Bottom view HA: T-slot for hexagon bolt Z WA L 4-OA through 4-NN through Section XX 4-OB depth of counter bore OL X 0.02 X 0.02
4 @1 w @3 !0 !2 @2 r o e @4 !0 y !3 12, 16 under 50 stroke 12, 16 over 30 stroke !5 20, 25 over 30 stroke under 100 stroke 12, 16 over 50 stroke @0 Under 50 stroke 20, 25 over 50 stroke Under 30 stroke 20, 25 over 100 stroke MGPM32 to 100 MGPL32 to 100 i !8 !7 u q y !1 !9 @3 !0 !2 @2 r o e !4 @4 @1 !0 w !
. 4-2 4.2.1 Operation . 4-2 4.2.2 Operation restart when alarm is generated . 4-3 4.2.3 Stopping the product . 4-5 4.3 Adjustment of bypass valve . 4-6 4.4 Check items after starting . 4-6 Chapter 5 Display and Setting of Various Functions . 5-1 5.1 List of Functions . 5-1 5.2 Function. 5-2 5.2.1 Key operations . 5-2 5.3 List of parameters . 5-6 5.3.1 Main Menu . 5-6 5.3.2 Alarm display
C.O. 4 220V AC 50/60Hz 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 10 5 24V DC 6 12V DC 7 240V AC 50/60Hz 15 2 9 Other 20 3 Option 25 4 1 1 1 2 Valve size 5 to 7 32 5 1 4 1 2 40 6 50 7 Note) Only air operated type.
-EC-M zx1-DR1-4 sra.3-4) NZXi071-EC-M zxl-DR16-4 NZZXl04-TB-A r:::r:l::t: l:l:l:lrrl:l:l:l :r:t:41:1it!