Body Size: 30, Back Flow: K (w/Backflow), Thread: Rc, Port Size: 03 (3/8), Options: DH (D+H), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa
Size: 30, Base Dew Point: H (-15°C), Type: A (Energy Saving Design), Equipment Connection: 4 (Modular Connection), Thread: N (NPT), Port Size: 03 (3/8), Draining: D (N.O. Auto Drain)
Body Size: 25, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30A, Thread: N (NPT), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 8 (Metal Bowl with Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Manual Override), A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Stations: 6 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 03 (Rc3/8), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: CD (Exhaust Cleaner for D Side Mounting), Option 2: W (IP65 Protection Compatible)
Body Size: 40, Thread: N (NPT), Port: 03 (3/8), Option: D [Float Type Auto Drain (N.O.)], Attachment: Standard, Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Stations: 12 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 03 (Rc3/8), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side), Option 2: W (IP65 Protection Compatible)
Stations: 7 Stations (Note: 1 Station is Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Electrical Entry Direction: U (U Side Mounting), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)
Size: 30, Base Dew Point: L (-40°C), Type: A (Energy Saving Design), Equipment Connection: 4 (Modular Connection), Thread: Rc(PT), Port Size: 03 (3/8), Draining: D (N.O. Auto Drain)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Body Size: 40, Thread: Rc, Port: 03 (3/8), Option: DG (D + G), Attachment: T (T-spacer), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 03 (3/8), Option: D [Float Type Auto Drain (N.O.)], Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right->Left)
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: BD (B + D), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: D [Float Type Auto Drain (N.O.)], Attachment: SV (S + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Stations: 7 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 03 (Rc3/8), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: F (G), Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: R (Flow Direction Right to Left), Semi-Standard 2: Standard