SMC Corporation of America
Elite Part Number Search
Search Results "VHS20-F02A-BS-X1"

Display Description Detail 1 LED lamp LED to indicate the condition of the gateway unit 2 ADDRESS Address switch This switch sets X1 and X10 in the address. 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.

With 1 shock absorber (Set on the driving cylinder side when packed.) 25 B 32 BS 40 Standard stroke Long stroke For minimum strokes for auto switch equipped style, refer to page 8-27-12. Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.

18 1500 IZS30-1900** 23 1900 End bracket (IZS30-BE) Intermediate bracket } gMi dQ j Thread for mounting M5 (Should be prepared by user) Attached thread M4X10L dQho g)iSu Angle ajustment available (90) } IZS30-BM ~ ~ }} ~~ )h dl g0i dQ j Thread for mounting M5 (Should be prepared by user) Angle ajustment available (90) Surface electric potential sensor (IZS30-D1) Sensor bracket (IZS30-BS

May S AS BS CS DS ES FS . Caution If instructions are not followed there is a possibility of injury or equipment damage. Jun T AT BT CT DT ET FT . When dispose the product, contact an industrial waste disposal company for disposal of the product. To minimize the risk, drain the fluid from the product when it is scrapped.

. = 4[V]x1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) K When an object is placed in a fluid stream, a vortex will be created in the fluid on the downstream side. This vortex is called a Karman vortex.

Double click the Slot X1 Interface and in the "General" window check "Prioritized startup". Double click the port (P1 (BUS IN) or P2 (BUS OUT)) which enables the EX260-SPN FSU function.

Station number setting Setting Setting range x10 0 to 6 x1 0 to 9 : The station number should be set within the range of 01 to 64. If the number is set to 00, or to 65 or above, the L ERR LED will turn on. : The station number must not be duplicated, this will cause an error. : The default setting is 00.

SD RD 24 V OV VCAM FG CAM Vt BS+ BDH BDL BSFG 24 V 0 V 24 V 0 V +24V 24G DA DB DG FG Description Description Description LED LED LED PWR. Light ON with transmission power input, light Off without it Green light ON with circuit power input PWR.

air inlet 475 1030 950 direction (Symbol: 3) Ventilation direction (Symbol: 2) Ventilation IDF100150F 6-3 Outer dimensions 6 5 IDX-OM-M050 Air Dryer 6 References 6-4 Electric wiring diagram [IDF100F/125F-30-] GFCI PE TB1 THR MC1 CM OLR MC2 FM1 FM2 PRR HM MC1 SWL PLC TB2 Y0 1 MC1 COM0 2 Y3 3 MC1 Y1 COM3 4 MC2 PRS1 X4 5 P 6 PRR COM1 Symbol Description X0 L CM Refrigerating compressor Y2 THR X1

Switch for setting address X1 and X10 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.

BS For minimum strokes for auto switch equipped style, refer to page 530. Applicable Auto Switch/Refer to pages 1719 to 1827 for further information on auto switches. Auto switch part no.

Y axis [Axis speed calculation] Target position Composite speed Composite travel distance =((X2-X1)2+(Y2-Y1)2+(Z2-Z1)2) (X2, Y2, Z2) Xaxis speed = ((X2-X1)/ Composite travel distance) Composite speed Y axis speed = ((Y2-Y1)/ Composite travel distance) X axis Composite speed Z axis speed = ((Z2-Z1)/ Composite travel distance) Current position Composite speed (X1, Y1, Z1) Z axis Caution

BS Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.

Nil B BS With shock absorber (1pc. on port side) The adjustment bolt is installed even when B or BS is selected. (except for 10) Refer to "Auto Switch Guide" (E274-A) for further details on auto switch units. Refer to pages 60 and 61 for auto switch circuit diagrams. Applicable auto switch types Lead wire length (m) Note 1) Load voltage Electrical entry direction Auto switch no.

SD RD 24V OV VCAM FG CAM Vt BS+ BDH BDL BSFG 24V 0V 24V 0V +24V 24G DA DB DG FG LED name LED name LED name PWR Content Content Content Green light turns on when line power is input Turns on during supply of communication power, turns off when there is no input Turns on during supply of communication power, turns off when there is no input PWR PWR Light off: When unit is off-line or power

Single acting nomally open: O.D. holding force, Single acting nomally closed: I.D. holding force Refer to "Effective Holding Force" for the holding force at each holding position, page 13 to 17. 11 Series MHK2 Wedge Cam Operation Gripper Construction Double acting Single acting ck 3 bs br 2 9 Open finger Normally open bt 5 6 bp 8 7 bq 1 4 bl bk bm Closed finger Normally closed bo bn Parts

ZS AS BS . Likewise, if a tube is bent or multiple elbow fittings are used, the piping Output shut off alarm function Jun T TT UT VT . ZT AT BT . resistance will increase and the flow rate will decrease. If the flow rate falls, the temperature stability will decrease.

If a stop valve or a silencer is connected to the exhaust port of VHS20/30, the effective sectional area should be larger than the figure indicated in the following table, to prevent malfunction caused by back pressure.

D-M9mA DC (+) Brown M2.5 x 4L Slotted set screw Main circuit of switch OUT Black Indicator light SMC 4 DC (-) Blue 2.8 2.7 24 D-M9BA 0.2 3 3.2 4 OUT (+) Brown 6 Most sensitive position Main circuit of switch OUT (-) Blue Indicator light/Display method ON OFF Operating range Display Red Green Red Optimum operating position 388 Made to Order Pilot Valve: SF4 SGC 2 2 1 A 05 G 10 1 T Z B1 A L S X1

22.8 0.49 6.3 P2 (Port size) EXH Model P1 P2 A B C D Applicable size VHS20-D 1/8, 1/4 1/8 48.5 23 40 37 AC20-D VHS30-D 1/4, 3/8 1/4 55 32 53 49 AC30-D VHS40-D 1/4, 3/8, 1/2 3/8 69.7 41.3 70 63 AC40-D VHS40-06-D 3/4 1/2 71.7 43.3 75 63 AC40-06-D VHS50-D 3/4, 1 1/2 86.5 44.5 90 80 AC50-D/AC60-D Model E F G H Applicable size VHS20-D 28 42 17.5 40 AC20-D VHS30-D 38 53 20 53 AC30-D VHS40-D 52