SMC Corporation of America
Elite Part Number Search
Search Results "RZQD32TN-75-10-M9BSAPC"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, CLEAN ROOM, ACTUATOR, CXS GUIDED CYLINDER, H5, 20MM CXS CLEAN-ROOM, 1.76369 lb, ModelStandard stroke (mm) 1015202530354045506070758090100CXSM200.400.420.440.460.480.4950.510.530.550.5850.620.640.660.700.74

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, CLEAN ROOM, ACTUATOR, CXS GUIDED CYLINDER, L5, 32MM CXS CLEAN-ROOM, 4.24389 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, CLEAN ROOM, ACTUATOR, CXS GUIDED CYLINDER, L5, 32MM CXS CLEAN-ROOM, 4.24389 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROUND BODY, ACTUATOR, CJ2 ROUND BODY CYLINDER, G5, 16MM CJ2 CLEAN-ROOM, .41336 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 63MM MGP BALL BEARING, ACTUATOR, MGP COMPACT GUIDE CYLINDER, PB, 63MM MGP BALL BEARING, 18.16902 lb

Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of t, Cylinder, Guide, with Auto Switch, GUIDED CYLINDER, 9.74 lb

Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of the table top. T-slots are provided on 3 faces of the MGF body (except port face), allowing mounting of various brackets. Optional auto switches

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, CLEAN ROOM, ACTUATOR, CXS GUIDED CYLINDER, H5, 20MM CXS CLEAN-ROOM, 1.45126 lb

.· Installation distance (IZD10-110) 10 to 50 mm (±0.4 kV at an installation distance of 25 mm).· Installation distance (IZD10-510) 25 to 75 mm (±20 kV at an installation distance of 50 mm).

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number