SMC Corporation of America
Elite Part Number Search
Search Results "SY100-30-3A-50"

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-W1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, MK-Z ROTARY CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, HE, 20MM MKA

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, MK-Z ROTARY CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, GE, 16MM MKA

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, MK-Z ROTARY CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, LE, 32MM MKA

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, MK-Z ROTARY CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, LE, 32MM MKA

9999.9 to 9999.9)Preset data (always held) {E2ROM (Warning display after writing approx. 65,000 times: )}Count input, Reset inputNo-voltage pulse input90 phase difference input20 kHzR.S. and COM terminals are shorted for 10 ms or more (Pulse input)10.8 to 13.2 VDC, 60 mAPreset outputCompare/Hold/One-shot (100 ms fixed pulse)5 ms or lessNPN open collector Max. 30 VDC, 50 mA21.6 to 26.4

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 984 lb

Size: 50, Thread Type: N (NPT), Port Size: 06 (3/4), Mounting: w/o Mounting Option, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Flow Direction: Left to Right, Pressure Unit: Z (Name Plate and Caution Plate for Bowl in Imperial Units: psi, °F)

Size: 50, Thread Type: N (NPT), Port Size: 10 (1), Mounting: w/o Mounting Option, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Flow Direction: Left to Right, Pressure Unit: Z (Name Plate and Caution Plate for Bowl in Imperial Units: psi, °F)

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, MK-Z, CLAMP CYLINDER, C68, 222 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 445 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, MK-Z, CLAMP CYLINDER, C68, 445 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 796 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 796 lb

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ001-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-W1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-H1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol20 to 908.0 (at 20C)3.0 (at 20C)?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?