override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
Operating range Cylinder model C D 8 8 8 8 Mounting bolt size M3 x 50 L M3 x 60 L M3 x 50 L M3 x 60 L M5 x 75 L M5 x 85 L M5 x 75 L M5 x 85 L M5 x 85 L M5 x 95 L M5 x 75 L M5 x 85 L M6 x 95 L M6 x 130 L M8 x 100 L M8 x 130 L 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20
/ZB041 Exhaust Characteristics Flow-rate Characteristics (Supply pressure: 51 psi (0.35 MPa)) 0.53 14.5 14.5 (15) (100) (100) Vacuum pressure psi (kPa) Vacuum pressure psi (kPa) 0.42 11.6 11.6 (12) (80) (80) Air consumption Vacuum pressure 0.32 8.7 8.7 (9) (60) (60) 0.21 5.8 5.8 (6) (40) (40) 0.11 2.9 2.9 (3) (20) (20) Suction flow 0 0 0 14.5 (0.1) 29 (0.2)43.5 (0.3) 58 (0.4)72.5 (0.5) 87
per minute 1 60 = x x Reference life cycles Cycles per minute 1 8 (daily operating time) Service life 1 60 = 1 8 50,000,000 50 x x 2083 days = 27 Process Pump Common Precautions 5 Be sure to read before handling.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 17-5-163 24 Series PB Performance Curves: Built-in Solenoid Valve Type/Air Operated Type Cycle 1 Hz Cycle 5 Hz Cycle 10 Hz 70 70 70 60 60 60 Total lifting range (m) Total lifting range (m) Total lifting range (m) 50 50 50 40 40 40 SUP = 0.7 MPa SUP = 0.7 MPa SUP = 0.7 MPa
Rated voltage Electrical entry 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz G Grommet C Conduit 3 110 VAC 50/60 Hz D DIN terminal 4 220 VAC 50/60 Hz T Conduit terminal 5 24 VDC Refer to the table (1) given below for availability. 6 12 VDC 7 240 VAC 50/60 Hz 8 48 VAC 50/60 Hz 9 Other (Contact us for inquiry) Refer to the table (1) given below for availability.
Electrical entry F: Plug-in type Option Port size Nil 01 Without sub-plate Rc 1 8 50 01 F Z VZS2 1 2 Plug-in 5 G 50 VZS2 Non plug-in 2 01 2 Coil rated voltage Symbol Thread type 1 2 3 2 position single 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Option Nil N T F Standard Rc NPT 1 Nil Z None With light/surge voltage suppressor Option NPTF 4 G S With surge voltage
T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL
6 35.3 17.9 21 3/8" 17 12.8 27.8 39.3 AS321F-02-08 AS321F-02-07 60 63 8 27.8 39.3 13.2 17 15.2 1/4" 18.5 41 29.5 23 37.8 21.3 42.8 43.3 48.3 AS321F-02-10 AS321F-02-09 67 18.5 63 10 29.5 21.3 48.3 18.5 43.3 42.8 15.2 41 21 37.8 5/16" 23 43.3 31.8 AS321F-02-12 AS321F-02-11 67 69 12 43.3 21 31.8 17.9 20.9 3/8" 22 44.3 32.8 19 19 AS321F-03-06 AS321F-03-07 55 55 6 39.3 17 27.8 13.2 12.8 1/4"
-30 0.012 MXQ12-20 MXQ12-20 MXQ12-40 0.02 0.04 0.008 MXQ12-20 MXQ12-10 MXQ12-10 0.01 MXQ12-10 0.02 0.004 0 0 0 20 40 60 80 100 20 40 60 80 100 160 40 80 120 Load (N) Load (N) Load (N) 96 Air Slide Table Series MXQ The graphs below show the table displacement when the static moment load is applied to the table.
Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
5 Port Solenoid Valve VQC1000/2000 Series Metal Seal Rubber Seal Connector Type Manifold IP67 enclosure compatible Power saving Power saving SV SYJ Standard: 0.4 W Standard: 0.4 W SZ RoHS (Reduced by 60% compared to current model) (Reduced by 60% compared to current model) VF VP4 High-pressure (1 MPa, Metal seal): 0.95 W High-pressure (1 MPa, Metal seal): 0.95 W VQ 1/2 VQ 4/5 VQC 1/2 VQC
1 2 100 VAC, Hz 200 VAC, Hz 50 60 50 60 3 4 5 6 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 7 240 VAC, Hz 50 60 Port size 50 60 Note 1) CE-compliant: Electrical entry is applicable only for the DIN terminal.
Electrical entry F: Plug-in Option Port size Nil 01 Without sub-plate Rc 1 8 02 Rc 1 4 2 50 01 F Z VZS3 1 Plug-in 5 G 50 VZS3 01 Non plug-in 2 Symbol Coil rated voltage Thread type Option 2 position single 1 2 3 4 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz Nil N T F Standard Rc Nil Z None With light/surge voltage suppressor NPT 1 110 VAC, 50/60 Hz Option NPTF S With surge voltage suppressor 220
Burst pressure Min. bending radius (mm) 100 15 20 30 60 75 75 60 48 36 24 25 13 20 to +60C (Water: 0 to 40 C) (No freezing) Operating temp. Nylon 12 Material Precautions How to Order Be sure to read before handling.
Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
MHT 0.6MPa 100 Gripping force N Gripping force N 150 0.5MPa MHY 0.5MPa 80 120 0.4MPa MHW 0.4MPa 60 90 0.3MPa -X 0.3MPa 40 0.2MPa 60 MRHQ 0.2MPa 20 30 MA D100 0 80 60 40 20 80 60 40 20 0 100 Gripping point L mm Gripping point L mm 449 Series MHF2 Model Selection Effective Gripping Force: Series MHF2 Step 2 External Gripping Internal Gripping The air gripper should be operated so that the
) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160 VAC side pressure (kPa)