121 F 182 182 242 242 G 15 15 16 16 H 24 24 40 40 I 382 382 422 422 J 414 414 472 472 K 428 428 L M ALT-5 ALT-5-IS ALT-9 ALT-9-IS 5 5 5 5 449 482 1050 ALF400 to 900, ALT-5/-9 Related Products: Oil Distributor VA, VB Series How to Order AL800 AL900 ALF ALT ALF ALT V A 4 6 Applicable tubing O.D.
181 241 302 362 422 13.5 to 20.0 121 181 241 302 362 422 483 543 603 Note 1) It takes approximately 0.3 seconds for the cylinder to operate to generate clamping force from an unclamping state (when no speed controller is installed).
549 519 L L1 L2 1445 VT317 Series Dimensions: Individual Exhaust Without mounting bracket/VV317-02-3-02 2 x 7 mounting hole Manual override (Non-locking) (Station 1) (Station n) Conduit (C) DIN terminal facing upward (136.6) Conduit terminal (T) Grommet (G) DIN terminal (D) 2n x 1/4 Applicable cable O.D. 6 to 12 L Dimension n: Stations Stations Formula L1 = 46 x n + 29 L2 = 46 x n + 14 2 121
With pressure gauge With vacuum pressure detection port Branch Dimensions ZL6mmm-m (Without supply valve or release valve) ZL6 Without valve Branch Vacuum (2/V) port1 2(V) 2(V) 2 x Rc1/2, G1/25, NPT1/2 (Recommended tightening torque: 28 to 30 Nm) 2(V) 1(P) With vacuum With pressure Branch Silencer exhaust EXH With vacuum pressure switch pressure detection port gauge EXH. port exhaust G 121
Model: 5 (VPA500), Exhaust Type: 41 (Common Exhaust), Stations: 4 Stations, Symbol: 1, Port Size: 03 (3/8), Thread Type: N (NPT)
Model: 5 (VPA500), Exhaust Type: 41 (Common Exhaust), Stations: 6 Stations, Symbol: 1, Port Size: 03 (3/8), Thread Type: N (NPT)
Model: 5 (VPA500), Exhaust Type: 41 (Common Exhaust), Stations: 3 Stations, Symbol: 1, Port Size: 03 (3/8), Thread Type: N (NPT)
Model: VPA500, Exhaust Type: Common Exhaust, Stations: 4 Stations, Symbol: 1, Port Size: 3/8, Thread Type: NPT
Model: VPA500, Exhaust Type: Common Exhaust, Stations: 6 Stations, Symbol: 1, Port Size: 3/8, Thread Type: NPT
Model: VPA500, Exhaust Type: Common Exhaust, Stations: 3 Stations, Symbol: 1, Port Size: 3/8, Thread Type: NPT
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to 101.2kPa., MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ, VP3/5/7 BODY PT 3/8, 4.09398 lb, SeriesBase modelPiping specificationsApplicable valveApplicable stations Note)Manifold base Weight: W [g] Stations: n 1P (SUP)port type3R (EXH)port typePort sizeVP500VV3P5-41CommonCommon3/8VP5442 to 20 stationsW
SMC's?VP300/500/700 series solenoid valve, offers high flow capacity and?reduced power consumption (1.55W standard, 0.55W with power saving circuit).? The VP series may be?used as either a?selector valve, or a divider valve.? It?is?available in a normally closed?or a normally open style. The series is vacuum applicable up to ?101.2kPa., MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ, VP3/5/7 BODY PT 3/8, 4.79505 lb, SeriesBase modelPiping specificationsApplicable valveApplicable stations Note)Manifold base Weight: W [g] Stations: n 1P (SUP)port type3R (EXH)port typePort sizeVP500VV3P5-41CommonCommon3/8VP5442 to 20 stationsW
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ, VP3/5/7 BODY PT 3/8, 3.52739 lb, SeriesBase modelPiping specificationsApplicable valveApplicable stations Note)Manifold base Weight: W [g] Stations: n 1P (SUP)port type3R (EXH)port typePort sizeVP500VV3P5-41CommonCommon3/8VP5442 to 20 stationsW
SMC's?VP300/500/700 series solenoid valve, offers high flow capacity and?reduced power consumption (1.55W standard, 0.55W with power saving circuit).? The VP series may be?used as either a?selector valve, or a divider valve.? It?is?available in a normally closed?or a normally open style. The series is vacuum applicable up to ?101.2kPa., MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ, VP3/5/7 BODY PT 3/8, 5.94329 lb, SeriesBase modelPiping specificationsApplicable valveApplicable stations Note)Manifold base Weight: W [g] Stations: n 1P (SUP)port type3R (EXH)port typePort sizeVP500VV3P5-41CommonCommon3/8VP5442 to 20 stationsW
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ, VP3/5/7 BODY PT 3/8, 5.94329 lb, SeriesBase modelPiping specificationsApplicable valveApplicable stations Note)Manifold base Weight: W [g] Stations: n 1P (SUP)port type3R (EXH)port typePort sizeVP500VV3P5-41CommonCommon3/8VP5442 to 20 stationsW
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to 101.2kPa., MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to 101.2kPa., MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ