78 14 19 19 6.5 6.8 7.5 27 32 39 25, 50, 75, 100, 125, 150 175, 200, 250, 300, 350 M8 11 12 39.5 107 14 44 M10 13.5 16.5 46 115 16.5 49 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st 25 25 < st 100 100 < st 200 200 < st 300 300 < st 350 38 47 55 30 40 50 13 9 14 18 104 44 60 70 72 92 110 40 50 63 1/8 1/4 1/4 20 22 22 6.6 8.6 8.6 124 124 128 11 14 14 200 200 200 24
(PNP) M9PAV*1 M9PA*1 M9PAV*1 M9PA*1 v v V v v 2-wire 12 V M9BAV*1 M9BA*1 M9BAV*1 M9BA*1 v v V v v Grommet Water resistant (2-color indication) With diagnostic output (2-color indication) 4-wire (NPN) 5 V,12 V H7NF F79F V V v v IC circuit 3-wire (NPN equivalent) 5 V A96V A96 A96V A96 V V IC circuit Reed auto switch Yes 200 V A72 A72H V V Grommet 100 V A93V*2 A93 A93V*2 A93
M6 x 1 depth 7 M6 x 1 effective depth 12 Number of mounting screws and distance between screws are different depending on the strokes. Refer to the Mounting screw dimensions (Distriction of stroke) below.
-XC7 Reversed Shaft 1 CRQ2B CDRQ2B Refer to How to Order on page 11-8-12.
KNS-R01-075-4 KNS-R01-100-4 KNS-R01-090-8 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 14 14 14 14 14 14 14 9 9 9 13 13 13 13 0.75 x 4 1 x 4 0.9 x 8 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 R 1/8 R 1/8 R 1/8 R 1/4 R 1/4 R 1/4 R 1/4 12 12 12 14 14 14 14 18 18 18 20 20 20 20 D 2 Connection thread H1 A L1 Reference dimensions after R thread installation. 862 Nozzles for Blowing KN Series Sensing
Rc 1/8 pilot port 2-Mounting hole Port size Rc (EXH port) Port size 2-Rc (IN, OUT port) IN, OUT EXH Port size Rc A Model Mounting hole C D E F G H K L B J 3 8 1 2 3 4 VPA3145 71 3 4 85 14 52 55 93 32 87.4 36 71 80 8.5 3 4 VPA3165 82.6 1 4 1 1 110 17 68 75 118 45 113 36 71 95 8.5 1 4 1 1 1 1 4 VPA3185 118 1 2 132 14 80 95 140 52 140 41 81 105 13 2 2 5-5-26
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
L E C T 1 3 J G S 1 S 1 2 J 2 E 2 3m 1 6.43 2 6.3 9 TB 12 - 3. 3.1 (1) TB Ver.5.11 TB Ver2.1LECPA No.0 1 LECPA TB Ver2.1LECPA No. 1 ) TB Ver1.** TB Ver2.**/ / (2)Tree TB Ver.5.11 MENU Data No. 2 Data Monitor JOG Test Alarm Setting Ver1.** Ver2.** 12 TB Ver2.1*LECPANo.0 Monitor No. 2 JOG Test 1 LECPATB Ver2.1*LECPA Alarm Setting Ver1.
. 10-1 10.3 . 10-2 10.4 . 10-2 11 R .11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 12 T . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 12.4 . 12-3 12.5 . 12-4 13 V . 12-5 13.1 . 13-1 13.2 . 13-1 13.3 . 13-2 14 . 14-1 14.1 . 14-1 IDF60/70/80/90 Series IDX-OM-W093 1 1.1 () 6.2 1.1.1 3 IDF60/70/80/90 Series 1-1 IDX-OM-W093 1.2 6 1.2.1 1.2.2 50 1.2.3 0 IDF60/70/80/90 Series
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VY1D00-5 VY1B0-5 VY120-5 1 V V V 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 A VY1D00-6 VY1B0-6 VY120-6 A 1 1 1 1 V V V 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 VY1D00-7 VY1B0-7 VY120-7 1 A 2 2 2 mA mA mA 4 0 8 12 16 20 4 0 8 12 16 20 4 0 8 12 16 20 VY1D00-8 0 5 10 15 20 VY1B0-8 0 5 10 15 20 VY120-8 0 5 10 15
-16DmZ M5 x 0.8 4.3 10 MHL2-20DmZ M6 x 1 7.3 12 MHL2-25DmZ M8 x 1.25 17.7 16 MHL2-10DmZ M4 x 0.7 1.4 5 MHL2-16DmZ M5 x 0.8 2.8 7 MHL2-20DmZ M6 x 1 4.8 7 MHL2-25DmZ M8 x 1.25 12.0 7 How to Mount the Attachment to the Finger 1.
-2 . 10-2 10-3 . 10-3 10-4 . 10-3 11 R 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4 . 11-2 11-5 . 11-2 12 S 12-1 . 12-1 12-2 . 12-2 12-3 . 12-2 13 T 13-1 . 13-1 13-2 . 13-1 2 13-3 . 13-1 13-4 . 13-2 13-5 . 13-3 14 V 14-1 . 14-1 14-2 . 14-1 14-3 . 14-2 14-4 . 14-2 15 15-1 . 15-1 3 IDX-OM-W014 i i i-1 () 3 i 1 1 3 IDU Series i-1 i-1 IDX-OM-W014 i i-2 5 i
(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133
port External pilot specifications (1) NM N1 N3 N7 N9 N11 M5 01 02 Symbol Mixed M5 threads 1/8 thread 1/4 thread 1/8" 5/32" 1/4" 5/16" 3/8" Applicable tubing O.D.
1 8 1 4 1 4 1 4 1 2 1 1 2 105 120 140 77 96 113 53 60 74 26.5 30 37 121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 Port size/Flange: 32F, 40F, 50F J (Valve open) Indicator (Option) Pilot port E 12(P1), 10(P2) Port size: refer to table below P1 P2 H H D B A 32 B C G F 4 x 2 x 18 mounting hole A Applicable flange 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H J Model VND50D-32F
DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR SIGNAL OUTPUT . 12-1 12.3 REMOTE OPERATION . 12-2 12.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 12
Regenerative error (Note 1) (Note 1) (Note 1) Alarms AL.31 1 0 1 Overspeed AL.32 1 0 0 Overcurrent AL.33 0 0 1 Overvoltage AL.35 1 0 1 Command pulse frequency alarm AL.37 0 0 0 Parameter error AL.45 0 1 1 Main circuit device overheat (Note 1) (Note 1) (Note 1) AL.46 0 1 1 Servo motor overheat (Note 1) (Note 1) (Note 1) AL.47 0 1 1 Cooling fan alarm AL.50 0 1 1 Overload 1 (Note 1) (Note 1)
T0425 T0604 TU 0805 T0806 1/8B T1075 TU 1208 T1209 1/4B TS 1612 3/8B T1613 1/2B 3/4B 1B [Calculation example] Size: 10 Operating pressure: 0.5 MPa Inner sectional area of piping: 12.6 mm2 4.9 4 2.5 12.6 6 4 19.6 8 5 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 16 12 127 12.7 133 16 13 204 16.1 366 21.6 598 27.6 Lengh of piping: 1000 mm Stroke: Center Counterclockwise