0050 0 A9 [CR][LF] :01 06 0050 0 A9 [CR][LF] Stop 0050 Control operation mode 1 :01 06 0050 0001 A8 [CR][LF] :01 06 0050 0001 A8 [CR][LF] Start 0051 Temperature setting 1 :01 06 0051 0BB8 E5 [CR][LF] :01 06 0051 0BB8 E5 [CR][LF] Set at 30.0 deg.C. 0052 Offset setting 1 :01 06 0052 0032 75 [CR][LF] :01 06 0052 0032 75 [CR][LF] Set at 0.50 deg.C.
06 FH440-08 FH440-10 FH440-12 FH640-03 FH640-04 FH640-06 FH640-08 FH640-10 FH640-12 3/8 3/8 10 10 FH441-04 FH441-06 FH441-08 FH441-10 FH441-12 FH441-16 FH441-20 FH441-24 FH641-04 FH641-06 FH641-08 FH641-10 FH641-12 FH641-16 15 (1/2B) 15 (1/2B) 1/2 1/2 20 20 20 (3/4B) 20 (3/4B) 3/4 3/4 50 50 Max. 21 MPa 25 (1B) 25 (1B) 1 1 80 80 Max. 7 MPa 32 (1 1/4B) 32 (1 1/4B) 1 1/4 1 1/4 120 120 40
VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust center) Rc 3/8: 49 Rc 1/2: 55 VH402-02 to 06 VH412-02 to 06 2 (Position) 1/4 to 3/4 2 1 1.28 VH4 Handle Operation Angle and Air Flow Direction VH420-02 to 06 VH430-02 to 06 3 (Closed center) (Refer to the figures of piping direction to the right.)
VH410-02 to 06 Rc1/4: 45(2.5) 4 3 3 (Exhaust center) VH401-02 to 06 VH411-02 to 06 Rc3/8: 49(2.7) Rc1/2: 55(3.1) 2 (Position) VH402-02 to 06 VH412-02 to 06 2 1 1.28 VH4 Handle operation angle and air flow direction 1/4 to 3/4 3 (Closed center) VH420-02 to 06 VH430-02 to 06 (Refer to figures of porting direction in the right.) 3 (Exhaust center) VH421-02 to 06 VH431-02 to 06 Rc3/4: 58(3.2
VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust center) Rc 3/8: 49 Rc 1/2: 55 VH402-02 to 06 VH412-02 to 06 2 (Position) 1/4 to 3/4 2 1 1.28 VH4 Handle Operation Angle and Air Flow Direction VH420-02 to 06 VH430-02 to 06 3 (Closed center) (Refer to the figures of piping direction to the right.)
N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40W-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50W-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D Contents Page 1.
Setting of switch operation 1_P/1_N (page 37) (Selection of display colour) Setting of Add dEC1 dEC2 (page 41) 3. Input of set values Setting of Setting of P1L/n1L Setting of P_1/n_1 P1H/n1H P1/n1 H_1 WH1 (page 40) (page 37) (page 39) 4. Delay time Setting of dtH1(ON) dtL1(OFF) (page 38) 5. Selection of display colour rED/Grn/1SoG/1Sor/2SoG/2Sor (page 41) 6.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
-D 91.4 87.4 93.9 40 50.6 AFM30-D 123.9 122.2 117.8 122.3 137.8 142.3 53 54.3 AFM40-D 155.6 153.9 149.5 154 169.5 174 70 58.3 AFM40-06-D 157.6 155.9 151.5 156 171.5 176 -28- Revision history Size 40-06 added.
AF-OMX0052-C PRODUCT NAME Air Filter MODEL / Series / Product Number AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D AF50-(F,N)06(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF60-(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2.
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
-D 91.4 87.4 93.9 40 50.6 AFD30-D 123.9 122.2 117.8 122.3 137.8 142.3 53 54.3 AFD40-D 155.6 153.9 149.5 154 169.5 174 70 58.3 AFD40-06-D 157.6 155.9 151.5 156 171.5 176 -28- Revision history Size 40-06 added.
AL-OMX0056-A PRODUCT NAME Lubricator MODEL / Series / Product Number AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-D AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)06(B)(-2,3,6,8,R,W,Z)-D AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,W,Z)-D AL60-(F,N)10(B)(-2,3,6,8,R,W,Z)-D Contents Page 1. Safety Instructions 2-6 2. Application 7 3. Standard Specifications 7 4.
Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 46 (5 Port/Base Mounted Common SUP Individual EXH), Stations: 6 Stations, A B Port Size: M5 (Base Mounted M5X0.8)
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 6 Stations, A B Port Size: M5 (Base Mounted M5X0.8)
Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 6 Stations, A B Port Size: M5 (Base Mounted M5X0.8)
Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 41 (5 Port/Base Mounted Common SUP Common EXH), Stations: 6 Stations, A B Port Size: M5 (Base Mounted M5X0.8)
Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 46 (5 Port/Base Mounted Common SUP Individual EXH), Stations: 6 Stations, A B Port Size: M5 (Base Mounted M5X0.8)