NB A S + Stroke Z + Stroke H (mm) A BA BB CA CB D F FB FC FT FX FY FZ GA GB H MM NN NA NB S Z Bore size (mm) 10 15 15 12 17 14 4 8 17.5 5.5 2.5 33 20 42 8 5 28 M4 x 0.7 M10 x 1.0 12.5 9.5 46 74 16 15 18.3 18.3 20 20 5 8 19 5.5 2.5 33 20 42 8 5 28 M5 x 0.8 M12 x 1.0 12.5 9.5 47 75 Double clevis style (D): CJ5DS R V CDH9 + 0.030 0 NB GA 0.030 0.060 Clevis pin ( ) Cdd9 Piping port 2 x M5 x 0.8

Pay attention not to cause breakage due to over tightening. 19 - Doc. No. ZQ-OM01301-A . Structural Drawing and Replacement of Part 7.1 Construction (single unit) Vacuum ejector Specifications Vacuum pump system specification Component Parts No.

(a combination of 1.2.4) Pro-No.bit1 BIT 2 Program designation < 1 > 5 Pro-No.bit2 (5) BIT 3 18 Pro-No.bit3 (18) STP-NO BIT 1 6 Stp-No.bit1 (6) BIT 2 19 Stp-No.bit2 (19) BIT 3 7 The terminal which designates the step to be executed. Used when executing steps (position movement). (a combination of 1. 2. 4. 8. 16. 32. 64.)

BIT 2 5 Program designation <1> BIT 3 Pro-no. bit2 5 18 STP-NO BIT 1 Pro-no. bit3 18 6 BIT 2 Stp-no. bit1 6 19 BIT 3 Stp-no. bit2 19 7 BIT 4 20 Stp-no. bit3 7 The terminal that designates the step to be executed. Used when executing steps (position movement). (Set by the binary system.)

22 32 28 40 28 40 33 50 33 50 43 29 43 29 28 19 28 19 18 11 18 11 12 7 8 5 5 3 3.8 2.5 1.3 1 0.7 VNB1-6A VNB1-8A VNB1-10A VNB24-10A VNB2-10A VNB24-15A VNB2-15A VNB34-20A VNB3-20A VNB44-25A VNB4-25A VNB54-32A VNB5-32A VNB54-32F VNB5-32F VNB64-40A VNB6-40A VNB64-40F VNB6-40F VNB74-50A VNB7-50A VNB74-50F VNB7-50F 1 8 1 4 770 520 770 520 500 330 500 330 320 210 320 210 220 130 140 90 90 55 70

Gripper Cam Type MHY2-20D 2 x M5 x 0.8 thread depth 8 Pin hole positioning (Mounting thread) 14 5 19 42 4H9 + 0.030 depth 4 0 4 x M4 x 0.7 through (Thread for mounting attachment) 8 4 x M5 x 0.8 thread depth 10 10 0.005 0.025 (Mounting thread) 5 9 2 x 5.5 through (Mounting hole) 2 x M5 x 0.8 thread depth 10 18 (Mounting thread) (Limted area for mounting attachment) 38 48 36 36 37 25 21H9

Auto switch Cylinder B Cylinder A CUJ cylinder Auto switch Magnetic substance Non-magnetic spacer of 2.5mm or more Without shielding plate d 10 L 6 8 Bore L d 19 6 19 6 19.5 6 The space can be reduced by attaching shielding plates (steel plates 0.2 to 0.3mm thick) to the sides of the cylinders facing each other.

Required facility water system Model Heat radiation Facility water specications HRS100-W-20 Approx. 19 Refer to "Facility water system" in the specications on page 8.

SUP, VAC port (4, 5/32") OUTx 3 2 5 EXH, ATM port (4, 5/32") 38 2-M3 x 0.5 thread depth 3.5 Bracket mounting hole L bracket (optional) Flat bracket (optional) 6-3.5 19 74 2-3.5 19 27 19 64 28 Minimum bending radius 80 Body +50 0 3000 15 35 (30.9) 8.7 4 9.9 Cable connector (4-wire) Straight type (optional) 7 14 Body Cable connector (4-wire) Right angle type (optional) 8.3 4.3 10.2 Minimum

M5 x 0.8 Use the connection thread. M5 x 0.8 Use the connection thread. Use the connection thread.

Dimensions inside are for rubber seal. 6-1/2, 3/4 1, 3, 5 port 32 (35) 32 (35) 35 35 3-11-9 10 Series EVS7Dimensions EVS7-10-FG-S-M0 1/2, 3/4-5 port 1, 4, 2, 5, 3 port 200 124 124 45 (14 port) 76 39 37 2-8.5 mouting hole 45 (12 port) 5 1 3 22 (4 port) 22 (2 port) 22 12 2 4 14 14 80 26 33 80 95 50 B A 4 2 19 19 5 1 3 1/8-2 port 12, 14 port 47 47 Manual override 8 71 65 2-8.5 mounting hole

12 14 15 4 4 5 9 11.5 17 92 97 106 106 132 132 11 11 11 11 21 21 1/8 1/4 1/4 3/8 3/8 1/2 35 40 43.5 43.5 56 56 27 27 31.5 31.5 38 38 19 19 19 19 23 23 1.7-34 End Lock Series MBB With Mounting Bracket Foot(L)/Locking at head end (Hl) Wl Hl/ Rl (mm) Port Cushion valve Stroke range Bore size (mm) ZZ LS ZZ LZ LY LX LT LS LH LD Y X 32 40 50 63 80 100 up to 700 178 144 170 50 53 32 3.2 136 30 7

Length TH0402 TJG-0402 18 5/32" TH0425 TJG-0425 18 TL0403 TJG-0403 18 1/4" TIHB07 TIL07 TJG-0604 19 TIHA07 TJG-0746 19 5/16" TH0806 TL0806 TJG-0806 20.5 3/8" TIHB11 TIL11 TJG-1065 23 TIHA11 TJG-1107 23 1/2" TIH13 TIL13 TJG-1395 24 *Stainless steel 316 is used for the TJG series. Spare Parts Description Tubing O.D. Part no.

Length TH0402 TJ-0402 18 5/32" TH0425 TJ-0425 18 TL0403 TJ-0403 18 1/4" TIHB07 TIL07 TJ-0604 19 TIHA07 TJ-0746 19 5/16" TH0806 TL0806 TJ-0806 20.5 3/8" TIHB11 TIL11 TJ-1065 23 TIHA11 TJ-1107 23 1/2" TIH13 TIL13 TJ-1395 24 *C2700 + Electroless nickel plated is used for the TJ series. Spare Parts Description Tubing O.D. Part no.

ACB ACB SYJ 2-4.5 (Mounting hole) SX 57.5 VK 52.5 51 3(R) 1(P) 3(R) 1(P) VZ 9 16 32 17 4 VF VFR 10 4 10 P=11 L2 VP7 36.5 41.5 L1 VP4 45 M plug connector (M) VQ D side U side VQ4 Stations 1 2 3 4 5 n Direct manual override VQZ (Non-locking) 2n-C4, M5 (A, B port) C4: 4 One-touch fitting M5: M5 thread VQD VZS 2(B) 2(B) 27.5 VFS 20 15 4(A) 4(A) 5 VS 46 12.5 P=11 VS7 L plug connector (L) n: Station

screw attachment ) 6 12 30.4 Max. 14 4-M8 x 1.25 Depth 12 (two on opposite side) 63 24 M5 x 0.8 3-R3 2 4 Finger opening port 17 32 23 27.5 7 11 45 42 69 8 54 2-8.5 through 2-14 depth of counter bore 14 107 Angle adjustment bolt 3-R3 12 3-6H9 depth 8 (one each on three sides) +0.030 0 10 3-6H9 long groove depth 4 (one each on three sides) +0.030 0 M5 x 0.8 Port B M5 x 0.8 Port A 50h9 0 0.062

LEFS 25 B 6N 1 20 0 1 DIN 1 6 16 25 25 I/O 32 32 40 40 1.5 m 1 1 3m 3 3m 3 5m 5 5 5m 40 16 25 32 40 16 25 32 ( ( DC24V NPN NPN A A LECP6/LECA6 6N 6N PNP PNP DC24V 6P 6P NPN NPN LECP1 1N * 1N * LECP1 PNP PNP 40 32 25 16 1P * 1P * 40 32 25 16 NPN NPN A A 10 mm 12 mm 16 mm 20mm AN * LECA6 AN * LECA6 PNP PNP B B 5 mm 6 mm 8 mm 10mm AP * AP * 100 mm 100 8m 8m 100 8 8 10m

Enter one of the "Valves (16 coils)" or "Valves (32 coils)" modules in Slot 1. Enter all other modules that are connected on the left hand side of the SI Unit (max. 8 modules).

offset 47 46 45 44 43 43 41 40 39 38 37 36 35 34 33 32 Item Flow measurement value (PD) Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item Temperature measurement value (PD) : The area is not used when the product without temperature sensor is selected.