cores) Brown Blue Flat cable AWG28 With power lines Without power lines Model PCW-9930661H PCW-9903491H 20 cores 40 cores 20 cores 34 cores 40 cores Flat cable AWG28 (7 wires/0.127 mm) Length 100 m roll Power lines AWG20 (21 wires/0.18 mm) Sheath O.D. 10.3 mm 12.0 mm 8.7 mm 11.8 mm 13.0 mm Note) The flat ribbon cable without power lines are not available from P/A.
Series SV2000 for EX120 Dedicated Output Serial Wiring. 6 7 8 10 10 10 10 10 10 10 11 11 11 11 11 11 12 12 13 13 13 15 16 16 17 19 20 21 21 23 23 24 24 24 24 24 25 26 27 27 30 30 31 32 33 34 35 36 37 37 39 40 40 41 42 44 45 45 50 50 51 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
40 40 Pressure loss [kPa] Pressure loss [kPa] Pressure loss [kPa] Supply pressure 200 kPa Supply pressure 400 kPa 30 30 30 20 20 20 10 10 10 0 0 0 0 400 800 1200 1600 2000 0 100 200 300 400 500 0 200 400 600 800 1000 Flow [L/min] Flow [L/min] Flow [L/min] IN Side Straight Piping Length and Accuracy (Reference Value) The piping on the IN side must have a straight section of piping with a
Port R Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Air (Standard) Oil (Standard) (V) Port P Port A Maximum Minimum 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V in parentheses is option symbol. Option Material No.
D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation
ISO compressed air quality class The class regarding the cleanliness of compressed air (solid particles, moisture and oil) stipulated by ISO 8573-1:1991 (JIS B8392-1:2000) Maximum oil concentration (mg/m3) Minimum pressure dew point (C) Maximum particle size (m) Quality class 1 2 3 4 5 6 0.01 0.1 1.0 5 25 70 40 20 3 7 10 0.1 1 5 15 40 Notation system Example) Solid particle size: 0.1 m
(page 40, "3,"). 2, After the security code is entered and the indication changes to [UnL], Press and hold the and buttons simultaneously for 5 seconds or longer. [000] is displayed and the new security code should be entered. For how to input the security code, refer to "How to input and change the security code".
Setting completed Adjust the set value. 1 Multi-channel Digital Sensor Monitor PSE200A Series 3-Screen Display Centralized Control Saves Installation Space. 66% reduction in installation space (Compared with the panel mounted Z/ISE20m) 40 mm PSE200A 138 mm 34.5 mm Panel mounted Differential Pressure Check Mode p. 16 One monitor displays 2 lines of differential pressure.
Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
Rail mounting type Electrical entry Grommet Oil proof vinyl heavy insulation cable 3.5 0.14 mm2 4 cores 3 m With one e-con connector Note) Lead wire Impact resistance 980 m/s2 Amplifier unit Insulation resistance 50 M (500 VDC) between lead wire and case Withstand voltage 1000 VAC for 1 min. between lead wire and case Ambient temperature 10 to 60 C Enclosure IP67 Weight 58 g (with connector
Electrical entry direction Perpendicular Perpendicular Perpendicular 3-wire Wiring type 2-wire Output type NPN PNP IC circuit, 24 VDC relay, PLC Applicable load 24 VDC relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) Power supply voltage 10 mA or less Current consumption Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA 80 mA or less 1.5 V or less (0.8
Function Setting 20 Function selection mode 20 Default setting 20 F0 Unit selection function 23 F1 OUT1 24 F2 OUT2 26 F3 Response time 28 F4 Auto-preset 29 F6 Fine adjustment of display value 31 F11 Display resolution 32 F80 Power saving mode 33 F81 Security code 34 F90 Setting of all functions 35 F96 Check of suction command signal 37 F98 Check of output 38 F99 Reset to the default setting 40
1 V7 LEFS 32 200 R H B B 3 M2 S r Motor type e Motor mounting position w Size q Accuracy Nil Basic type H High precision type 25 32 40 Nil In-line R Right side parallel L Left side parallel Symbol Type Output [W] Size Compatible driver V6 AC servo motor (Absolute encoder) 100 25 LECYM2-V5/LECYU2-V5 V7 200 32 LECYM2-V7/LECYU2-V7 V8 400 40 LECYM2-V8/LECYU2-V8 u Motor option t Lead [mm] i Cable
mA or less at 24 VDC 5 ms or less 1% F .S. or less IP40 Operating: 0 to 60C, Stored: 10 to 60C (With no condensation) Operating/Stored: 35 to 85%RH (With no condensation) 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 980 m/s 2 in X, Y, Z directions, 3 times each (De-energized) 3% F .S. or less 1000 VAC
Series S070 is a super compact direct acting 2/3 port solenoid valve that meets the miniaturization needs of analyzers and semiconductor manufacturing equipment. S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base). Valve width is 7mm. 3 port solenoid valve, direct operated
Series S070 is a super compact direct acting 2/3 port solenoid valve that meets the miniaturization needs of analyzers, medical equipment and semiconductor manufacturing equipment. S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base). Valve width is 7mm. 3 port solenoid
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED, STACKING, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT M5), .02023 lb
Auto switch specifications Connector wiring diagram D-A93 Auto switch type C: Multiple connector (6P) Applicable load Relay, PLC Auto switch Lead wire color Terminal item no. 1 2 3 4 5 6 Blue Brown Brown Blue OPEN () OPEN (+) CLOSE (+) CLOSE () Load voltage 24 VDC 100 VAC 6 5 4 Load current range and maximum load current 5 to 40 mA 5 to 20 mA 3 2 1 Contact protection circuit None Internal
Vacuum pressure) Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum unit setting Applicable fluid Power supply voltage Current consumption Switch output ZSE30AF (Compound pressure) 100.0 to 100.0 kPa 105.0 to 105.0 kPa 500 kPa 0.1 kPa Air, Non-corrosive gas, Non-flammable gas 12 to 24 VDC 10%, Ripple (p-p) 10% or less (with power supply polarity protection) 40