When used in a balance control circuit, there are instances in which the check valve cannot release, even though the pilot pressure is 50% of the operating pressure. In these cases, the pilot pressure should be the same as the operating pressure. 3. Use in load factor less than 50%. Speed control under normal operations may not function. Series AQ 2.
See Specific Product Precautions. 0.2 GD 0 0 10 20 30 40 50 Operating temperature (C) Port size Model Rated flow (L/min (ANR)) Note 1) Weight 60 80 100 100 100 100 300 400 500 500 35 g 35 g 35 g 35 g 60 g 150 g 190 g 190 g 190 g 260 g 4 (One-touch fittings) 6 (One-touch fittings) 8 (One-touch fittings) Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 8 (One-touch fittings) 10 (One-touch fittings
75E 0.75 to 75 kW 0.10 to 12.4 60 50 to 150 0.32 to 12.5 Non-freon, Power supply is not necessary.
(OUT1) [ CoL] Display colour (OUT1) [ SoG] ON: Green, OFF: Red Page 32 [ oU2] Output mode (OUT2) [ HYS] Hysteresis mode (Flow) Page 36 [ 2ot] Switch operation (OUT2) [ 2_P] Normal output Page 36 50% of max. rated flow [ 2.00] 2.00 L/min (4 L type) [ 8.0] 8.0 L/min (16 L type) [ 20.0] 20.0 L/min (40 L type) [ 50] 50 L/min (100 L type) [ 126] 126 L/min (250 L type) [ P_2] Set value (OUT2)
ble acting Single rod o12, o16/5to30 o20, o2t5 io 50 o32, @40l5lo 1N o50, 063/10 io 1m Double rod 612, E1U5lo 30 amlo @Q/5to50 o50, 0631 0 to 50 Large bor lize Double acting Single rod101o 300 Double rod 10 to 300 Standard Double acting Single @d o12. a16/5 lo 3A o20 p2t510 50 o32, o40l5 to 1 00 o50 to o10cy10 to 100 Double rod 012, 016/510 30 a20. o25/5 lo 5A 632, 64US lo 1OA o50 lo 0100
Table 7-1 Water Quality Standards Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 Sulfate ion (mgSO42-/L) Max. 200 Max.50 Acid consumption (pH4.8) (mgCaCO3/L) Max. 100 Max.50 Total hardness (mgCaCO3/L) Max. 200 Max.70 Calcium hardness (mgCaCO3/L) Max. 150
Manifold 1/8, 1/4, (3/8) 2, 3, 4.5, 6 17-2-74 VDW200/300 C.O. 3 port Single unit M5, 1/8, 1/4 0 to 0.9 1, 1.6, 2, 3, 4 Pilot operated Diaphragm operation 1/4 to 1 32A, 40A, 50A 10, 15, 20, 25, 35 40, 50 17-3-33 VXD21/22/23 N.C./N.O. Single unit 0.02 to 1 Pilot operated Disk operation 1/4 to 2 32A, 40A, 50A 10, 15, 20, 25, 35 40, 50 VXP21/22/23 17-3-43 N.C./N.O.
: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 01, 23, 03, 04, 06, 07 500 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification
100 150 Load (N) 0 50 100 150 Load (N) 0 50 100 150 Load (N) 200 16 16 16 L=120mm L=120mm L=120mm MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.08 0.12 0.06 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.10 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.06 0.04 0.08 0.04 0.06 0.04 0.02 0.02 0.02 0 0 0 50 200 250 Load (N) 150 100 50 200 250 Load (N)
113 48 1 12 40 26 39 XLF-40 65 158 66 2 11 55 41 63 XLF-50 70 170 79 2 11 75 52 68 XLF-63 88 196 100 3 11 87 95 70 69 XLF-80 90 235 117 3 11 114 110 83 96 XLF-100 108 300 154 3 11 134 130 102 131 XLF-160 138 315 200 3 11 190 180 153 112 9 XL*-OMJ0003-D 5.
50 100 200 300 500 12 25 50 75 125 Purge air flow rate (L/min (ANR)) Note 3) Inlet air pressure (MPa) 0.7 Inlet air temperature (C) Inlet air saturation temperature (C) Ambient temperature (C) Dew point indicator purge air flow rate Port size (Nominal size B) 25 25 25 1 L/min (ANR) Note 1) No freezing Note 2) ANR represents the flow rate converted to the value under 20C at atmospheric pressure
Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at
25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 50, 63 1200 80: 1400 100: 1500 80, 100 Note 1) Intermediate strokes other than the above are produced upon receipt of order.
m or less Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance) Max. voltage 24 VDC Max. load current 50 mA Max. load inductance 0.5 H Insulation voltage 300 V 600 V Protection against electric shock Class II (EN60947-5-1: 2004) 4 VP500/700-X536, X538, X555 Symbols Safety limit switch Made by OMRON Terminal/Pin Numbers (Built-in switch 2N.C.)
load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance) Max. voltage 24 VDC Max. load current 50 mA Surge voltage suppressor Varistor Indicator LED Max. load inductance 0.5 H Insulation voltage 300 V 600 V Protection against electric shock Class II (EN60947-5-1: 2004) 4 VP500/700-X536, X538, X555 Symbols Safety limit switch Made by OMRON Terminal/Pin Numbers (Built-in switch 2N.C
Changes from the standard type are: KT10F KT10H KT10R KT10J KT10L KT10N KT10P Option Other Parameters HF Source pressure Cv 6000 psig (41.4 MPa) 0.12 Wetted Parts Material S B 316 SS 316 SS Brass Bronze 300 SS series Vespel (Option: PEEK) PCTFE Viton (Option: Polyurethane, Buna-N, Ethylene propylene) PTFE C 300 SS series 316 SS Wetted Parts Body Inlet filter Piston and trim Seat, main valve
113 48 1 12 40 26 39 XLA-40 65 158 66 2 11 55 41 63 XLA-50 70 170 79 2 11 75 52 68 XLA-63 88 196 100 3 11 87 95 70 69 XLA-80 90 235 117 3 11 114 110 83 96 XLA-100 108 300 154 3 11 134 130 102 131 XLA-160 138 315 200 3 11 190 180 153 112 10 XL*-OMI0009-E 5.
113 48 1 12 40 26 39 XLA-40 65 158 66 2 11 55 41 63 XLA-50 70 170 79 2 11 75 52 68 XLA-63 88 196 100 3 11 87 95 70 69 XLA-80 90 235 117 3 11 114 110 83 96 XLA-100 108 300 154 3 11 134 130 102 131 XLA-160 138 315 200 3 11 190 180 153 112 9 XL*-OML0013-B 5.
60 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)
The machine stops once after moving the distance set in Pr.50 "Setting for the movement amount after near-point dog ON" from the OFF --> ON position. Later the operation restarts and then stops at the first zero signal to complete the machine OPR.