SMC Corporation of America
Elite Part Number Search
Search Results "RDQB20-30M-M9PL"

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9PL

Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9PL

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9PL--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 3M

Size: 40, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 30mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable

Size: 40, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 30mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable

Accuracy: Basic Type, Size: 25, Motor Mounting: Top Mounting Position, Motor Type: S2 [AC Servo Motor, (Incremental Encoder), Output 100W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 30mm, Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 5m, Driver: A1 (LECSA1-S, 100~

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 63mm, Port Thread Type: TN (NPT), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 63mm, Port Thread Type: TN (NPT), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 63mm, Port Thread Type: TF (G), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: L (w/By-Pass, Left-Hand Piping, Drop Prevention), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)

Magnet: D (Built-in), Mounting: G (Rear Flange), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 63mm, Port Thread Type: TN (NPT), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector

Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Port Thread Type: TN (NPT), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)