SMC Corporation of America
Elite Part Number Search
Search Results "LEY32C-400-R8C918"

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 200mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 8 (Rail Mounting

Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 200mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller

Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 150mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 300mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 8 (Rail Mounting

Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 8 (Rail Mounting

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 200mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Body Bottom, 2 Locations, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 8m, Controller Type: JXC, Step Motor

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 25, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 200mm, Motor Option: w/o Lock, Vacuum Port: Right, Positioning Pin Hole: Body Bottom, 2 Locations, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 8m, Controller Type: JXC, Step Motor

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting, Communication

Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 200mm, Motor: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting:

Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 150mm, Motor: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 300mm, Motor: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting, Communication Plug

. -76No.PS-OMW0012-C Unit specification and measurement value (PD) Range Unit Rated pressure range Display / settable range A to B C to D kPa 0 to 2.000 -0.200 to 2.100 Pa 0 to 2000 -200 to 2100 Mbar 0 to 20.00 -2.00 to 21.00 2 kPa Psi 0 to 0.2901 -0.029 to 0.305 (0.002) mmH2O 0 to 203.94 -20.4 to 214.1 Pressure gauge measurement value (PD) 0 to 4000 -400 to 4200 MPa 0 to -0.101 0.010 to

H 5 Initial power/ Power 100 VAC 800/180 1200/300 1600/400 200 VAC 3200/180 4800/300 6400/400 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for the size 16 models.

H 5 Initial power/ Power consumption (W) 100 VAC 800/180 1200/300 1600/400 200 VAC 3200/180 4800/300 6400/400 Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for the size 16 models. 200V The heaters are PTC thermistor type design.

XL-25 XL-40 XL-50 XL-63 AC90240V Ass'y XLA25-60S-1 XLA25-60S-1 XLA25-60S-2 Ass'y 1 1 1 H4 AC100V 200/40 200/50 400/100 / AC200V 800/40 800/50 800/100 Ass'y XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 Ass'y 1 1 1 1 H5 AC100V 200/40 400/70 400/80 600/130 / AC200V 800/40 1600/80 1600/80 2400/130 XL-80 XL-100 XL-160 AC90240V Ass'y XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 Ass'y

800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-50,XLD-160 XLD-63,XLD-80,XLD-100 S 1 SUS304+ 4 1) S S O 2) S O FKM 5 O 6 S O 2 FKM 9 S SUS304 10 11

Parameter Functioning in Manual Mode For the position indication (P value), zero / span setting (parameter code: 400) functions as it is. Reflection of Changed Content in Parameter Mode The changed content is reflected at the time when the mode moves from parameter to manual, and then moves to auto mode*1.

(mm) 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Weight(kg) 3.15 3.35 3.55 3.75 3.95 4.15 4.35 4.55 4.75 4.95 5.15 5.35 5.55 5.75 5.95 6.15 6.35 6.55 6.75 6.95 0.53 Additional weight for lock(kg) 4 Model LEFS40 Stroke(mm) 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 Weight(kg) 5.37 5.65 5.93 6.21 6.49 6.77 7.15 7.33