Flow Range: 10~100 l/min, Thread: G thread, Port Size: 3/4, Wiring Specification: -, Output Specification: -
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 3/4, Wiring Specification: -, Output Specification: -
L/min 1.052.5 L/min 052.5 L/min 5.00 V 20.0 mA 90% 10% PFM750 80% 20% 1.040.0 L/min 1.042.0 L/min 042 L/min 4.20 V 16.8 mA 70% 30% 60% 40% 92% 8% 2100 L/min 2105 L/min 0105 L/min 5.00 V 20.0 mA 90% 10% PFM711 80% 20% 290 L/min 295 L/min 095 L/min 4.60 V 18.4 mA 70% 30% 280 L/min 284 L/min 084 L/min 4.20 V 16.8 mA 60% 40% 420 mA 15V [mA] [V] -76No.PF-OMJ0005CN-I Revision history E F [2016
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: None, Made to Order: X731 (Compatible with Argon and Carbon Dioxide Mixed Gas)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Size: 10, Motor Size: L (Compact Type), Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 50mm, Motor Cable Mounting Direction: L (Entry on Left Side), Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 5, Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: No Cable, Controller Mounting: 8 (DIN Rail Mounting)
Size: 10, Motor Size: L (Compact Type), Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 25mm, Motor Cable Mounting Direction: L (Entry on Left Side), Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 5, Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: No Cable, Controller Mounting: 7 (Screw Mounting)
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 60 (10 Bit Digital Input), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 60 (10 Bit Digital Input), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: Rc(PT), Port Size: 1 [1/8 (1000)], Accessory: C (L Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 60 (10 Bit Digital Input), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: N (w/oCable Connector), Pressure Display Unit: 5 (kPa)
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 60 (10 Bit Digital Input), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 1 [1/8 (1000)], Accessory: C (L Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)
With the color zone limit indicator, users can set up the gauge for quick, "at a glance" indication of the appropriate operating pressure. Adjustable red rings indicate low or excessive pressure while a needle in the green zone indicates appropriate pressure for the operation. Pressure ranges vary from 0 to 1 MPa. Red and green color zones for improved visibility of pressure control range
With the color zone limit indicator, users can set up the gauge for quick, "at a glance" indication of the appropriate operating pressure. Adjustable red rings indicate low or excessive pressure while a needle in the green zone indicates appropriate pressure for the operation. Pressure ranges vary from 0 to 1 MPa. Red and green color zones for improved visibility of pressure control range
Element Length: A (ℓ250), Port Size R: 10 (1), Element Type: L (Micromesh, Stainless Steel 316/Nickel Brazing Material), Nominal Filtration Accuracy: 10 μm, Element Seal Material: T (Fluororesin)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C4 (ø4), Output Specification: A (Out 1: NPN; Out 2: NPN)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C4 (ø4), Output Specification: B (Out 1: PNP; Out 2: PNP)
Flow Range: 11 (10~100 l/min), Thread: F (G thread), Port Size: 10 (1"), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 11 (10~100 l/min), Thread: F (G thread), Port Size: 10 (1"), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))