C2SF-C C4SF-J C4SF-W C4SF-6 AD47-6 AD48-6 C4SF-6J C4SF-6W C4SF-2 AD47-2 AD48-2 C4SF-2J C4LF-8 AD47-8 AD48-8 C4LF-8J C2SF-C Drain AD27-C AD27-C C2SF-J C3SF-J C4SF-J Polycarbonate C2SF-J C3SF-J AF50, AF60 C3SF-W C4SF-W C3SF-W C2SF-CJ C2SF-CJ C3SF-6 C4SF-6 C2SF-6 C1SF-6 AD17-6 C1SF-2 AD17-2 C3SF-6 C2SF-6 C1SF-6 OUT IN C2SF-6C C2SF-6C AD37-6 AD47-6 AD27-6 AD37-6 AD17-6 AD27-6 AD38-6
C2SF-C C4SF-J C4SF-W C4SF-6 AD47-6 AD48-6 C4SF-6J C4SF-6W C4SF-2 AD47-2 AD48-2 C4SF-2J C4LF-8 AD47-8 AD48-8 C4LF-8J C2SF-C Drain AD27-C AD27-C C2SF-J C3SF-J C4SF-J Polycarbonate C2SF-J C3SF-J AF50, AF60 C3SF-W C4SF-W C3SF-W C2SF-CJ C2SF-CJ C3SF-6 C4SF-6 C2SF-6 C1SF-6 AD17-6 C1SF-2 AD17-2 C3SF-6 C2SF-6 C1SF-6 OUT IN C2SF-6C C2SF-6C AD37-6 AD47-6 AD27-6 AD37-6 AD17-6 AD27-6 AD38-6
Normally open Grommet, Grommet terminal Conduit terminal DIN terminal Grommet, DIN terminal Electrical entry VNB01V VNB02V VNH 12 (P1) 10 (P2) Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 15% to +10% of rated voltage VND DC Air operated Allowable voltage fluctuation Temperature rise 1 2 1 2 VCC 50C or less (When rated
Normally open Grommet, Conduit, DIN terminal, Other (Option) VNB01V VNB02V Grommet, Grommet terminal, Conduit terminal, DIN terminal Electrical entry 10 (P2) 12 (P1) Air operated Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, other voltage (Option) 24 V, other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) DC 2 (B) 1 (A) 2 (B) 1 (A) Allowable voltage fluctuation
12 V IC circuit 12 V 5 V, 12 V IC circuit Relay, PLC Diagnostic indication (2-color indicator) 24 V Yes Grommet 12 V 5 V,12 V 12 V IC circuit Water resistant (2-color indicator) 3-wire (NPN equivalent) Grommet 24 V Reed auto switch A96V A96 IC circuit 5 V Yes A93V2 A90V A93 A90 100 V IC circuit Relay, PLC 2-wire 12 V No 100 V or less 1 Water resistant type auto switches can be mounted
IC circuit Solid state switch Reed switch 5 V A96V A96 Yes Grommet IC circuit Relay, PLC A90V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV A90 A93 M9N M9P M9B F9NW F9PW F9BW F9BA 100 V 5 V, 12 V 12 V No 2-wire 24 V Yes 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V Relay, PLC Yes IC circuit Diagnostic indication (2-color display) 5 V, 12 V Grommet
indication (2-color indicator) 2-wire 3-wire (PNP) 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V,12 V 3-wire IC circuit E76A 5 V (NPN equivalent) Yes Grommet E73A E80A 24 V 12 V 5 V,12 V 100 V 2-wire Relay, PLC IC circuit N0 100 V or less Lead wire length symbols: 0.5 mNil (Example) M5BW 3 m L (Example) M5BWL 5 m Z (Example) M5BWZ Solid state auto switches marked with are produced
D B Vacuum suction port M5 x 0.8 Piping port 2-M5 x 0.8 33 32 10 J depth 1.5 3 5.5 5 12 9.5 +0.030 0 4 Section AA Mounting base side B D +0.030 0 depth 1.5 3 Q QL 11-/22-MXP12-25 Without magnet and switch rail 2-M2 x 0.4 depth 3 8 5.7 3.5 L 6-M4 x 0.7 depth 4.5 20 20 2-M3 x 0.5 depth 3.5 (mm) G H J K L M Q QL S V W Z Model 10 40 68 22 24 29 40 18 15 59 55 76 11-/22-MXP12-15 30 60 98 40
, D-A93(V), D-A96(V) Auto Switch Specifications D-A96 D-A90 D-A90V D-A93 D-A93V In-line D-A96V Auto switch part no.
D-M9(V) D-M9W(V) D-M9A(V) Auto switch mounting bracket part no.
A or less 24 VDCj 10pA or less 1.5 V or less (10mA: 0.8 V of less) 24 VOCj 1opA or less R e d : O N 1 mS or less solid state switch 3 Wirc lC circuit 28 VDC l5OmA 0.8 V or less 2 V or less (10mA: 0.8 V or less) 24 VDC: 10pA or less 24 VDC] 10llA or less ON: red light emilUng diode ON: red lighl milling diode 1 mS or less ftlo$I{ildl Smies CIA Reed Type Internal Circuit D-A59W.
A or less 24 VDCj 10pA or less 1.5 V or less (10mA: 0.8 V of less) 24 VOCj 1opA or less R e d : O N 1 mS or less solid state switch 3 Wirc lC circuit 28 VDC l5OmA 0.8 V or less 2 V or less (10mA: 0.8 V or less) 24 VDC: 10pA or less 24 VDC] 10llA or less ON: red light emilUng diode ON: red lighl milling diode 1 mS or less ftlo$I{ildl Smies CIA Reed Type Internal Circuit D-A59W.
Allowable Kinetic Energy E max=0.43 (J) V=Vax1.4=350x1.4=490mm/s W 30 xV2= x0.492=0.36 (J) Ev= 2g 2x9.8 Load Rate a5= E = 0.36 =0.84 Emax 0.43 3. Examination of Load Rate a = 0.84 1 OK With above allowable value, there is no problem on the selection.
(Up to 20 mA)/3 V or less (Up to 40 mA) 0.8 V or less Red LED illuminates when turned ON.
+ 02 1/4 V 03 3/8 V 04 1/2 V 06 3/4 V 10 1 V + e Port size 1(P), 2(A) a Mounting Nil Without mounting option V V V V B With bracket V V V V + Option b Pressure gauge Nil Without pressure gauge V V V V G Round type pressure gauge (with limit indicator) V V V V + r c Silencer Nil Without silencer V V V V S Silencer (Built-in) V V V V + 1 100 VAC V V V V 2 200 VAC V V V V 3 110 VAC [115
or higher +100 V to +400 V +30 V to +100 V Within 30 V 30 V to 100 V 100 V to 400 V 400 V or lower Light ON Positive Static neutralization completion Flash at 4 Hz Detects the electric potential difference and outputs in an analog voltage.
(mm) Dimensions Electrical entry A B C D E G H J Z Model Grommet Conduit DIN terminal Conduit terminal Q R S T U V W N X Y VV2CW2 49 20 24.5 28 4.5 38 17.3 34.5 63.5 22 45.5 44 43.5 46 58 41.5 66 99 77 VV2CW3 57 25.5 28.5 30 5.5 42 19.3 38.5 74 24 55 45.5 53 48 60 51 68 101 86.5 VV2CW4 57 25.5 28.5 30 5.5 42 20.8 41.5 81.5 26 62.5 47.5 60.5 50 62 58.5 70 103 94 17-2-59
Panel mount Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8 44 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.
Panel mount Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8 44 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.