5 AS-FG AS-FP AS-FM AS321F-02 Meter-out type AS3201F-02 Meter-in type AS3211F-02 AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ Component Parts No.
VK Applicable solenoid valve Type 25 (Non plug-in type) How to Order D 25 05 00C VV4Z1 VZ 4(A), 2(B) port G L M D G L M D VZ1120-M5 Stations VF VZ110-M5 (3 port valve) 02 2 stations 1(P), 3(R) port One-touch fitting for 6 VFR Applicable blanking plate assembly VZ1000-10-2A 20 20 stations SUP/EXH block mounting position VP4 DIN rail length specified B D U Both sides: 2 to 20 stations D side
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.
D X IDK02-100 IDK02-200 IDK04-100 IDK04-200 IDK06-100 IDK06-200 100 200 100 200 100 200 120 220 140 240 140 240 2 x 1.2 D 4 x 2.5 Inner sleeve 6 x 4 Note) Dimensions at 40% relative humidity. Dimensions may change if the relative humidity changes.
/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
I { 0 s l I l 6 l ; D.0 t' 6 l 0.6 0.5 o.4 0.3 6 ' ) !
D: Unit for replacement Ex.) If an adsorption confirmation switch is replaced for a vacuum switch on ZX1071-K15LZ-PBC, indicate as ZSE2-0X-15C-D. In this case, mounting screws P3270148-49 (2 pcs.) are required. If the unit is used on its own, not combined with others, D is not required. Ex.)
15.2 40.4 35.4 15 18.5 11 R 1/4 17 34.4 29.4 55 18.5 46.5 28.2 19.7 10 ASD430F-02-10S 18.5 58 21 49.3 31 6 ASD530F-02-06S 12.8 74 17 48.3 25.2 20.3 8 ASD530F-02-08S 15.2 76 18.5 51.3 28.2 41.9 46.9 48.8 43.8 19.8 23 15.4 R 1/4 19 42.8 37.8 10 ASD530F-02-10S 18.5 80 21 54.1 32.6 23.1 12 ASD530F-02-12S 83 20.9 22 55.9 34.4 6 ASD530F-03-06S 74 17 12.8 48.3 25.2 20.3 8 ASD530F-03-08S 93 18.5
. 9-5 9.1.6 HRLE090-W-40. 9-6 9.2 REFRIGERANT AND GWP VALUE . 9-7 9.3 DIMENSIONS . 9-8 9.3.1 HRLE050-A-20. 9-8 9.3.2 HRLE050-W-20. 9-9 9.3.3 HRLE090-A-20/40. 9-10 9.3.4 HRLE090-W-20/40. 9-11 9.4 FLOW DIAGRAM . 9-12 9.4.1 HRLE050-A-20-*,HRLE090-A-20/40. 9-12 9.4.2 HRLE050-W-20-*,HRLE090-W-20/40. 9-12 9.5 COOLING CAPACITY . 9-13 9.5.1 HRLE050-A-20. 9-13 9.5.2 HRLE050-W-20. 9-13 9.5.3 HRLE090
Applicable tubing M01 3.18/2 Barb fittings (6/4) Barb fittings 4/2.5 M02 Stations Note) The outside and inside diameters of the applicable tubing are indicated for the barb fitting. 02 03 2 stations 3 stations D side U side Station 3 2 1 20 20 stations Note) Maximum of 20 stations Electrical entry Grommet/Plug lead C How to Order Valves S070 M 5 B G 32 Port size Symbol 32 40 Connection
Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) Back pressure: 0.5 MPa Supply pressure: 0.5 MPa IR2000-02 IR2000-02 IR2000-02 ARJ 0.204 0.5 0.2 AR425 to 935 Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure P2 (MPa) 0.4 0.202 Set point 0.15 ARX 0.3 0.200 AMR 0.1 0.2 0.198 ARM 0.05 0.1 0.196 ARP 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0
PWR COM D D D D D D 3 2 1 Station D side How to Order Solenoid Valves SV 1 1 0 0 F 5 Note) Note) Available with manifold block for station addition. Refer to pages 77 and 81 of SV catalog (ES11-81A).
AS-FG AS-FP AS-FP AS-FM AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 715
AS-FG AS-FP AS-FP AS-FM AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 715
Grommet PLC 24 VDC 5 ~ 40 mA Rear Clevis Pin NCD-J010 10 110VAC 5 ~ 20 mA NCD-J016 16 D-C76 Grommet PLC 4 ~ 8 VDC 20 mA Double Rod Clevis NY-J010B 10 24V AC/DC or less 50mA NY-J016B 16 D-C80 Grommet PLC 48V AC/DC 40mA Rod Jam Nut JM-005 8 100V AC/DC 20mA JM-006 10 D-C73C Connector PLC 24 VDC 5 ~ 40 mA JM-02 16 D-C80C Connector PLC 24V AC/DC 50 mA Mounting Nut JM-025 8 or less JM-03 10 D-H7A1
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 l/min (ANR) Back pressure: 0.5 MPa Supply pressure: 0.5 MPa IR2000-02 IR2000-02 IR2000-02 0.204 0.5 0.2 Set pressure (MPa) Set pressure (MPa) Set pressure P2 (MPa) 0.4 0.202 Set point 0.15 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0 100 200 300 400 0 100 200 300 400 500 600 700 Flow rate (l
41.7 40.4 35.4 15.2 18.5 15 11 R(PT)1/4 17 34.4 29.4 18.5 55 28.2 46.5 19.7 10 ASD430F-02-10S 18.5 21 58 31 49.3 6 ASD530F-02-06S 12.8 17 74 25.2 48.3 20.3 8 ASD530F-02-08S 15.2 18.5 76 28.2 51.3 41.9 46.9 48.8 43.8 23 19.8 15.4 R(PT)1/4 19 42.8 37.8 10 ASD530F-02-10S 21 18.5 80 32.6 54.1 23.1 12 ASD530F-02-12S 22 20.9 83 34.4 55.9 6 ASD530F-03-06S 17 74 12.8 25.2 48.3 20.3 8 ASD530F-03-08S
220-02-F 320-03 (02) 320-03-F (02) 420-04 420-04-F 121F-M3 131F-M3 121F-M5 (U10, 32) 131F-M5 (U10, 32) 221F-01 231F-01 2211F-01-06 221F-02 231F-02 321F-03 (02) 331F-03 (02) 421F-04 431F-04 1000F 2000F 2050F 3000F 4000F 1001F 2001F 2051F 3001F 4001F 230F 330F 430F 530F 630F 330F 430F 530F 630F Manifold regulator 4-, 5-port solenoid valve VQ Directional control valves 0 1000 2000 4000 5000