SMC Corporation of America
Elite Part Number Search
Search Results "HRZ008-L1-F"

G1, Symbol N: NPT1) Tank port size Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) Supply side pressure range MPa 0.2 to 0.5 Automatic water fill function (Standard) Supply side water temp. range oC 5 to 35 Automatic water fill port size Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2) Over flow port size Rc1 (Symbol F: G1, Symbol N: NPT1) Fluid contact part material Metal Stainless steel, Copper (Brazing

selection RX(n 3)0 RY(n 2)B Absolute value/incremental value to Reserved RY(n 2)C RX(n 3)9 to Reserved RX(n 3)A Problem ALM 15 RY(n 2)F RX(n 3)B Remote station communication ready CRD RY(n 3)0 to Reserved RX(n 3)C RY(n 3)9 to Reserved RY(n 3)A Reset RES RX(n 3)F Note.

selection RX(n 3)0 RY(n 2)B Absolute value/incremental value to Reserved RY(n 2)C RX(n 3)9 to Reserved RX(n 3)A Problem ALM 15 RY(n 2)F RX(n 3)B Remote station communication ready CRD RY(n 3)0 to Reserved RX(n 3)C RY(n 3)9 to Reserved RY(n 3)A Reset RES RX(n 3)F Note.

Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.

OR-1860-120F F: FKM E: EPDM For VCB30 OR-2380-130F F: FKM E: EPDM For VCB40 OR-2600-180F F: FKM E: EPDM e When external leakage occurs after disassembling a valve, replace the above seals.

F: FKM E: EPDM For VCB30 OR-2380-130F F: FKM E: EPDM For VCB40 OR-2600-180F F: FKM E: EPDM If external leakage occurs after replacing the coil, replace the above seals. When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .

Items don't need to be changed in positioning operation. a < Movement Method> When the absolute position is required, set Absolute Position Accel Decel Pushing F TriggLV Moving F Area 1 Area 2 In pos No.

Vertical upward: Lifter Vertical downward: Press Horizontal: Chucking l l m m F m Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F Maximum speed (mm/s) Load center of gravity position l (mm) Maximum speed (mm/s) up to 300 up to 500 up to 700 up to 300 up to 500 up

Note) Set ua so that the cushion approach speed u does not exceed 0.5m/s (or 0.4m/s in the case of the 80 or 100) 3.17-18 Compact Guide Cylinder Series MGP Operating Conditions F(N) Bore size (mm) Stroke (mm) Allowable lateral load (Air cushion) Model 200 175 150 125 100 75 50 25 MGPM 32 37 46 29 16 F MGPL 28 35 47 69 49 54 59 66 MGPM 75 87 103 46 20 43 48 54 62 MGPL 73 70 90 123 CL 65 71

F A F Lr 16 16 16 Lr = 120mm MXQ16-125 MXQ16-100 MXQ16-75 0.04 MXQ16-125 MXQ16-10 MXQ16-50 0.06 0.12 MXQ16-20 MXQ16-30 MXQ16-75 MXQ16-40 MXQ16-75 MXQ16-40 MXQ16-100 MXQ16-125 Table displacement mm Table displacement mm Table displacement mm 0.03 MXQ16-50 MXQ16-50 MXQ16-40 MXQ16-100 MXQ16-30 0.04 0.08 0.02 MXQ16-30 MXQ16-20 MXQ16-20 MXQ16-20 0.02 0.04 MXQ16-10 MXQ16-10 0.01 MXQ16-10 0 0 400

D R J (mm) so M8x1 .2S 14 ~ 63 M1Ox1.5 18 80 M12x1.7S 22 NoIe, DIller dlmellSlOIls are same as llYcugh hole type. acnSlu (mm) A 8 C D E F H ..

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Installation example Nm L 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150 160.5 171 181.5 192 202.5 213 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 278.8 299.8 (mm) : L1 shows the dimensions of the VQC1000 series solenoid valve.

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max. Model Port size Model Port size 120 150 AS800 AS900 1 1 , 2 74 93 204 262 192 250 80 94 AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 15-9-33

AC, with indicator light n L L1 L2 2 87 100 3 125 138 4 163 176 5 201 214 6 239 252 7 277 290 8 315 328 9 353 366 10 391 404 L1 = 38n + 11, L2 = 38n + 24 n: Station Formula for manifold weight M = 0.16n + 0.1 (kg) 4-16-4