Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto
Bearing Type: Slide Bearing, Bore Size: 25mm, Thread Type: NPT, Stroke: 100mm, Stroke Adjustment: 0 to 25, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Extension Type
Bearing Type: Slide Bearing, Bore Size: 16mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 100mm, Stroke Adjustment: 0 to 25, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Extension Type
Bearing Type: Slide Bearing, Bore Size: 32mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 100mm, Stroke Adjustment: 0 to 25, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Retraction Type
Bearing Type: Slide Bearing, Bore Size: 100mm, Thread Type: NPT, Stroke: 100mm, Stroke Adjustment: 0 to 25, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Extension Type
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.??The series is designed for high side load applications found in material handling, lifting and stopping. The?cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing
Model: MSQ, Precision: B (Basic), Size: 200, Suffix: R (Shock Absorbers), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Model: MSQ, Precision: B (Basic), Size: 70, Suffix: R (Shock Absorbers), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)