Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.
D (for PA3000 automatically operated type) Discharge rate 5 0.040 125 (cycles/min) = = Cycles per minute Discharge per cycle Reference life cycles 1 1 = x x Service life Cycles per minute 8 (Daily operating time) 60 1 1 100,000,000 = x x 60 8 125 1666 days = 17-5-145 6 Series PA/PAX/PB Precautions 5 Be sure to read before handling.
Intrinsically Safe Valve 5 Port Solenoid Valve Series 53-SY5000/7000/9000 Body Ported Electrical Entry L and LL Hazardous Location Class I Division 1 Groups A, B, C, D Electrical Entry TT Hazardous Location Class I, II, III Division 1 Groups A, B, C, D, E, F, G Single Unit Warning Do not install in Zone 0 (as defined in IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009)
+ , C8D , ) ( ) ( : C%=D C&=D , 9 ! &' = 2 + ! , E , ! !
Connected A B C D E F G H I J IDF190D JIS10KFF 80A(3B) flange 750 1510 1320 375 480 600 700 800 355 427 IDF240D JIS10KFF 100A(4B) flange 770 1550 1640 385 703 730 700 800 355 467 Auto drain is included in the package.
-14No.EX-OMP0004CN-I D 3 -15No.EX-OMP0004CN-I LED LED LED L ERR L RUN PWR ON OFF PWR(V) ON OFF -16No.EX-OMP0004CN-I DIP (0.2 Nm) -17No.EX-OMP0004CN-I 5 L ERRLED 00 65 L ERRLED HOLD/CLEAR HOLD/CLEAR No.1 HOLD ON CLEAR OFF No.2 ON 110 OFF -18No.EX-OMP0004CN-I EX260-SMJI/O (1 32 /32 ) SI [01] QJ61BT11N EX260-SMJ1/2 I/O (1 ) (RY) (RX) (RX) (RY) E0H RX0FRX00
D Auto identification function Display units can be selected using either or . This function automatically identifies the pressure range of the pressure sensor that is connected to the multi-channel pressure sensor controller, thus eliminating the need of having to reset the range again after replacing the sensor.
2-T1 L3 L2 L1 Model T1 T2 D L1 L2 L3 XTO-2571-02 Rc1/4 52 52 21 57 XTO-2571-03 Rc3/8 XTO-1239-02 Rc1/4 84 80 37 79 XTO-1239-03 Rc3/8 Rc1/4 XTO-1239-04 Rc1/2 XTO-1719-06 Rc3/4 98 98 40 90 XTO-1719-10 Rc1 !
/faq/en/images/pdf/g-01FtypeD-with-sub-connector.pdf" target="_blank">⑦ Type 01F with D sub-connector
Note) For the electrical connection of the DIN terminal type, refer to ①, ②, and ③.
D-sub connector for Series VQ1000/2000 solenoid valves. The D-sub connector reduces installation labor for electrical connections. Using the D-sub connector (25P), (15P as semi-standard) conforming to MIL standard gives a wide interchangeability. A top or side receptacle position can be selected in accordance with the available mounting space. Support a maximum of 24 stations.
D-sub connector for Series VQ1000/2000 solenoid valves. The D-sub connector reduces installation labor for electrical connections. Using the D-sub connector (25P), (15P as semi-standard) conforming to MIL standard gives a wide interchangeability. A top or side receptacle position can be selected in accordance with the available mounting space. Support a maximum of 24 stations.
D The setting time from when the input signal reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the flow can be displayed or set by the digital flow switch.
NOTE D class grounding (with the ground resistance of 100 ohm or less) should be performed for ground terminal, and ground at one point. -13No.EX-OMK0004-B Pin layout and connection diagram of power supply connector cable (unit: mm) Model No.: EX500-AP-S (Refer to page 31.) Pin No.
D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment of 1 kPa, e.g., 1, 2, 3, , Digit (min. setting unit) 99, 100. F Fine adjustment mode See "Fine adjustment of indicated value". Abbreviation of full span or full scale which means the max. fluctuation range.
Model AME250 AME350 AME450 AME550 AME650 AME850 AME150 12000 (1) 12000 Rated flow (l/min (ANR)) 500 1000 2000 3500 6000 200 Port size (Nominal size B) 1 8 1 4 3 8 , , , , , , , , , , 1 4 3 8 1 2 3 8 1 2 3 4 1 2 3 4 1 1 3 4 1 1, 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.
Body Size: 2000, Port Thread: Rc, Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Flow Direction: Left to Right
Body Size: 2000, Port Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Port Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Port Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None or Manual Override, Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Port Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)