Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: None, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
7 w e r !8 Lead wire color Dot marking Terminal no. @1 @6 @5 Black None q !9 Brown None w y t @0 u Red None e Orange None r Yellow None t Pink None y Circular Connector Cable Assembly Terminal No. Blue None u Purple White i Gray Black o Lead wire color Dot marking Terminal no. White Black !0 Black None q White Red !1 Brown None w Yellow Red !2 Red None e Orange Red !
F = degrees Fahrenheit S = SeCOndS NUmin = Normal liters per mlnute World Wide QS\E Support...
HAA15/22 Air inlet Air outlet Port size Ball valve Power source code Port size A 460 588 394 484 33 52 70 70 59 60 485 580 428 505 320 333 150 150 150 150 320 400 70 94 58 65 200 200 480 610 220 220 225 238 Model HAA15 HAA22 B C D E F G H J K L M N P Q R S 1B union union 1 2 B 1 HA AT ID AMG AFF AM Misc. 14-15-3
E-P HYREG VY1 Series ARJ This hybrid regulator combines a regulator and a solenoid valve. AR425 to 935 ARX AMR Stepless control through electric signals ARM Port sizes M5 to 2 inches can be covered by combining an ultra-compact electro-pneumatic pilot valve and a 3 port high-capacity exhaust main regulator.
To confirm by calculation, use formula (1) on the right and check kinetic energy of load: E will be within the allowable value below.
Vertical downward mounting (use Spring lock-up) ON OFF Locking ON Extend up E E OFF Lockinq As compared wilh Diagram 3, this circuit employs 5-port instead A and s-port 3 position solenoid valve (pressure center) instead of Sol As compared with Diagram 2, this circuit employs 3-port 2 position solenoid valve inslead of s-port 3 position solenoid valve leaving the others unchanged.
Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.
1 towards the right, and the pressure at the right side of top diaphragm e decreases, causing top diaphragm e to move to the right. Then, valve y moves away from the left surface of top diaphragm e, the outlet pressure flows from port A via the valve hollow and is discharged through port (atmosphere).
Z A + Stroke B + Stroke L W E M K J 2 x P (Rc, NPT, G) (Port size) 100 Auto switch Minimum lead wire bending radius 10 H thread effective depth C 4 x N through F Q I E M Z A + Stroke B + Stroke L W G M K J Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N P Q W Z A B A B 50 10 to 50 37 29 42.5 34.5 15 18 57 9 M10 x 1.5
How to order L E C C G 1 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions 70 - (3) Cable between branches (between the branch connectors) i. How to order L E C C G 2 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions (4) Branch connector i. How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 71 - 8.