, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300
40 510 30 50 70 100 200 300 2 10 30 50 70 100 200 300 Eccentric distance L (mm) Eccentric distance L (mm) Continuous line: Operating pressure 0.4MPa or more Selection graph to 700mm/s Selection Example: Vertical Upward Mounting 100 50 Selection conditions Mounting: Vertical upward (lifter) Maximum speed: 500mm/s Load weight: 40kg Eccentric distance: 80mm Load weight m (kg) Refer to graph
(Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed. Cylinder tube Piping port variations provide a high degree of freedom Piping port positions can be selected to accommodate the installation.
(Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed. Cylinder tube Piping port variations provide a high degree of freedom Piping port positions can be selected to accommodate the installation.
(Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed. Cylinder tube Piping port variations provide a high degree of freedom Piping port positions can be selected to accommodate the installation.
For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.
) 1 W (With indicator light: 1.1) DC 2 2 1.4 (With indicator light: 1.5) 100 V 110 V [115 V] 1.6 (With indicator light: 1.7) 1.7 (With indicator light: 1.8) 3 1 3 1 Apparent power (VA) AC 2.3 (With indicator light: 2.4) 200 V 2.5 (With indicator light: 2.6) 2.7 (With indicator light: 2.8) 220 V [230 V] Surge voltage suppressor Refer to page 4-2-11.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VQC2000 800 700 600 500 400 300 200 100 0 VQC4000 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open.
50C to 100C (122F to 212F), and a piston speed of less than 200 mm/s (7.87 inch/s), the XB6 specifications can be used. (3) As for XB6, regarding the temperature range (over 50C to 60C) (122F to 140F) which overlaps the one of standard products, consider the tendency of operating temperature (upper, lower limits), then choose a model.
, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 2000 2000 2000 2000 2000 2000 32 40 50 63 80 100 125 Minimum Stroke for Auto Switch Mounting 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400
V 200 V or less 24 V or less IC circuit Grommet Relay, PLC 12 V Connector 2-wire 24 V IC circuit PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with
100 300 400 500 600 700 0.4 MXJ8 0.3 0.5 0.35 Rubber stopper 0.4 0.30 0.2 Load mass W kg Metal stopper 0.25 0.3 0.20 0.15 0.2 100 50 200 300 0.1 100 50 200 300 400 500 Average speed Va mm/s 0.10 500 700 Average speed Va mm/s Collision speed V mm/s 0.05 400 600 0.00 200 100 300 400 500 600 0 Collision speed V mm/s (Average speed x 1.4) 700 Table (2) Max.
Vertical Horizontal l : Load eccentricity m Mounting orientation m L L Up to 100 Up to 300 Up to 500 Up to 100 Up to 300 Up to 500 Maximum speed (mm/s) 50 (4) 200 (6) 50 (7) 200 (9) 50 (10) 200 (12) (2) 100 (5) 100 (8) 100 (11) Load eccentricity (l mm) (1) (3) Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also
320 0.7 MPa 500 0.7 MPa 280 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.7 MPa 0.6 MPa 0.6 MPa 160 0.5 MPa 240 0.5 MPa 400 0.4 MPa 0.4 MPa 0.3 MPa Lateral load F (N) Lateral load F (N) Lateral load F (N) 200 0.3 MPa 120 0.2 MPa 300 0.2 MPa 160 80 120 200 80 40 100 40 40 120 100 80 60 180 140 100 60 240 200 160 120 80 Point of application L (mm) Point of application L (mm) Point of application
Tank model VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 394 Rc 3/8 VBAT20 VBAT20S 305 206 674 180 200 100 400 Rc 1/2 430 Rc 1/2 444 Rc 3/8 VBAT38 VBAT38S 355 256 824 205 250 150 500 Rc 3/4 480 Rc 1/2 14-9-9
AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 Material Part no.
Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Electrical entry G C T TL Grommet Conduit Conduit terminal Conduit terminal with indicator light Clip part no. Note) Indicate the valve model no. as a label will be attached to the clip.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 1 8 1 4 ZFA200 L1 1 Number of manifold stations Model Symbol 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10 200 212 300 312 38 50 48 60 ZFA100 L2 L1 L2 ZFA200 13-10-3
I direction \ j '--r:_ _ _ System diagram Supply by Lrser comFcrnecFic rouilo|'s $.0nie$ ll( Proilrd tooumr 30 :t0.03. 08; 2mm lead o5 stepping a a a a 80 08; 5mm lead 100 08; 6mm lead t0.05 200 @8; 12mm lead :a]8:?lrrin:Faq l: ':l ' :S? sleptrr.lS 19!1{11n]!