This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/O CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.85016 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 3.85808 lb
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.62970 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.62970 lb
The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.Stroke reading cylinder with position feedback, Resolution: 0.1mm, Water resistance improved by changing sensor unit filter, Power supply
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.91663 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/O CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.91663 lb
The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.Stroke reading cylinder with position feedback, Resolution: 0.1mm, Water resistance improved by changing sensor unit filter, Power supply
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.62000 lb
Description Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 105 105 (5) Size: Perform setting as shown below. Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MIN. 2 byte MAX.110 words MAX.220 byte Output MIN. 1 word MIN. 2 byte MAX.110 words MAX.220 byte When configuration assembly fundtion is not used: Set to "0".
Description Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 105 105 (5) Size: Perform setting as shown below. Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MIN. 2 byte MAX.250 words MAX.500 byte Output MIN. 1 word MIN. 2 byte MAX.248 words MAX.496 byte When configuration assembly fundtion is not used: Set to "0".
Value range: 10 10, in 1 ms increments Unit: ms F_WD_Time 150 A CRC signature, which is calculated automatically via all F-Parameters and ensures error-free transmission of the F-Parameters.
Value range: 1 10, in 1 ms increments Unit: ms F_WD_Time 150 Safety integrity (SIL according to IEC61508) of the module. Safety functions up to SIL 3 can be achieved with the module. The safety integrity level that can actually be achieved depends on the parameterization, the structure of the sensor, and the cable installation: See Section 8.2 Parameterisation.
Table 4-1 EX245 24 V DC +20% -15% 1ms IP65 () (IEC60529) 10M -FE 500VAC IEC61131-2 500VAC1 -FE IEC61131-2 -10 to 50 -20 to 60 35%85% RH 80 kPa 108 kPa ( 2000 m ) 66 kPa 108 kPa ( 3500 m ) 10 Hz to 57 Hz 0.75 mm 57 Hz to 150 Hz 49 m/s 2 XYZ 2 XYZ 3 EN 60068-2-27/29 EMC , 2014/30/EU, IEC61326-3-1 , 2006/42/EC, EN 62061, EN ISO 13849 TUV , EN 61508, EN 62061, EN ISO 13849
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
Only air, N2, are applicable. [6000] 6000 L/min (PF3A712H) [F 1] [ 150] 150 L/min (PF3A703H) The accumulated flow has exceeded the accumulated flow range. (For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Set temperature range -10.0 to 60.0 oC Lowest configurable increment 0.1 oC specifications Power supply voltage 21.6 to 30 VDC Electrical Current consumption 150 mA or less Protection Polarity protection Flow rate 4 3.0%F.S. Pressure 3.0%F.S. Accuracy Temp. 5 2.5 oC. Repeatability (Flow rate/Pressure) 1.0%F.S.
Max. 150 NL/min 3000 NL/min PF2A703H 5.5 CFM 106.0 CFM 300 NL/min 6000 NL/min PF2A706H 10.5 CFM 212.0 CFM 600 NL/min 12000 NL/min PF2A712H 21.0 CFM 423.5 CFM : Analogue output is based on the rated flow range at normal condition. Displayed flow range is based on standard condition. Therefore, the range of rated flow and the displayed flow are different..
Performance Performance data shown in this chapter is based on an electrified plate (dimensions: 150 x 150 mm, electrostatic capacity: 20pF) defined by ANSI standard (ANSI/ESD STM3.1-2015). Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the workpiece. 5-1.