This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 10MM CUJ CLEAN ROOM, ACTUATOR, CUJ COMPACT MINI FREE-MOUNT, E5, 10MM CUJ CLEAN ROOM, 0.34696 lb
The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size, Cyl, Free Mount
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, ME, 40MM CQ2 DBL-ACT AUTO-SW, 1.15329 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, .69409 lb
Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, left, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9BL
Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 50, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, left, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9BL
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9BL--Solid State , Gen. Purpose, 2 Wire, Horizontal, 3M
The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size, CYL, FREE MT
Magnet: D (Built-in Magnet), Mounting Direction: B (Through-hole: ø4 to ø10; Lateral Mounting: ø12 to ø20), Bore Size: 10mm, Stroke: 20mm, Rod End Thread: Rod End Female, without Thread for ø4, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Made To Order Option: XB24, High
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 15mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 4mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 8mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 4mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 6mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 4mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 10mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 15mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 15mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.)