Maximum load impedance: Power supply voltage 12V: 300 Power supply voltage 24V: 600 Minimum load impedance: 50 Reduce/Increase supply pressure to within the regulating pressure range. Applied pressure error Brown DC(+) Supply pressure is below the minimum regulating pressure.
Delivery Pressure: G [5 to 600 psig (0.034 to 4.1 MPa)], Relieving: 0 (Non Relieving), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 12 (NPT 3/4 Inch), Gauge Port, Inlet: 10 (1000 psig/bar (7 MPa), Gauge Port, Outlet: 6 [600 psig/bar (4.1 MPa)], Pressure Gauge Unit: psig/bar, Option: HF [High Flow (Cv: 2.0)]
HT135)50 to 140F (10 to 60 C) (no condensation)600 W (Clear water), 400 W (Fluorinert FC-3283) Note 2)900 W (Clear water), 600 W (Fluorinert FC-3283) Note 2)?0.018 to 0.054F (?
HT135)50 to 140F (10 to 60 C) (no condensation)600 W (Clear water), 400 W (Fluorinert FC-3283) Note 2)900 W (Clear water), 600 W (Fluorinert FC-3283) Note 2)?0.018 to 0.054F (?
It cannot be adjusted by a shock absorber. 10 to 80 C Ambient temperature range DSpring force: (N) Extended 1.96 4.22 6.86 8.34 Retracted 3.83 6.18 15.3 20.50 -X It denotes the values at the maximum energy absorption per one cycle. Therefore, the operating frequency can be increased according to the energy absorption.
700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 AU Flow rate (/min (ANR)) Flow rate (/min (ANR)) AF AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ARX21-01 ARX21-02 0.35 0.35 IR 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) VEX 0.25 0.25
Dimensions Metric size Inch size Model d Weight g D1 D2 L1 L2 L3 Model d Weight g D1 D2 L1 L2 L3 Max. Min. M1 Max. Min.
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
Material Code Body Poppet 316L SS Hastelloy C-22 Diaphragm 316L SS Hastelloy C-22 Seat material S 316L SS secondary remelt Gauge port (Inlete, Outletr) Code Material PCTFE (Standard) Vespel 4) Pressure gauge 2) psig/bar unit MPa unit No gauge port No pressure gauge (Connections: 1/4 inch face seal male) SH Code No code No code Surface finish VS Range options 1) 4) Not available with SH material
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
Description Note Material Element set 1 SFD-EL200 With 3 O-rings 323 SFD Series Dimensions SFD100-C SFD100-C Dimensions Model A 81 B SFD100C04 C06 C08 4 23 6 81 8 82 26.2 SMC 23 14.7 51 17 Bracket mounting dimensions Applicable tubing O.D.
Do not connect the white wire of the sensor to c of the display unit.
Applicable tubing O.D. d L2 L3 M L2 L3 M D2 D2 L1 L1 L4 L4 H (Hexagon width across flats) H (Hexagon width across flats) D3 D3 L5 A1 A2 L5 A1 A2 D1 D1 T T Metric Size L4 L5 A1 A2 M Max.
Nil C 0.4 to 4 L/min 1.8 to 20 L/min 4 to 40 L/min The cable and connector are shipped unassembled.
ASD230F ASD330F/430F ASD530F/630F Applicable tube O.D. d L2 L2 L3 L3 M M D2 D2 L1 L1 L4 L4 H H (Width across flats) (Width across flats) D3 D3 A1 L5 L5 A1 A2 D1 D1 A2 T T Inch L4 L5 A1 A2 M MAX.
Code Connections NPT 1/4 inch 1/4 inch compression 4 4T Seat material Material Code Material Viton (Standard) PTFE Kalrez No code TF KZ Code Body Brass Nozzle Diaphragm B S SH Gauge port (Inlete, r) 316 SS 316 SS Pressure gauge 1) 316 SS Hastelloy C-22 Hastelloy C-22 Code psig/bar unit MPa unit Pressure gauge unit 2) No code No gauge port Ports Unit psig/bar MPa Code No pressure gauge (Connections
Blue DC () Number of pins Manufacturer Connector size Applicable series Separate type C. CORRENS & CO., LTD. VA-4D OMRON Corporation XS2 NPN open collector 30V, 80mA Residual voltage 1V or less M12 Yamatake-Honeywell Co., Ltd. 4 PA5-4I Hirose Electric Company HR24 Sensor Blue Brown Black NC DDK Ltd. CM01-8DP4S C.
0 e New PFA q Body New PFA w Sensor Super PFA e Tube PPS r Housing A PPS t Housing B PPS y Housing C POM u Bushing PPS i Cap FKM o Gasket FKM !0 O-ring Stainless steel 304 !1 Thread PVC !2 Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !