Magnet: D (Built-in Magnet), Mounting: B (Basic), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 75mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: TF (G), Stroke: 75mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

Mounting: B (Through Hole), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 75mm, First Stroke: 20mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

Bearing Style: Slide Bearing, Bore Size: 50mm, Port Type: -, Stroke: 75mm, Locking Direction: Retraction Stroke Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Through

Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 50mm, Thread: TN (NPT), Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 50mm, Thread: NPT, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -

Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 63mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: Double Knuckle Joint, M6 w/Tap, Option: K [Pedestal (for 75, 100, 150 Strokes Only)], Auto Switch: P [(w/o Auto Switch(Built-in Magnet); with Switch Mounting Rod), Lead Wire or Prewired Connector: -, Number: -

(Crimping tool: model number DX170-75-1) MXQ In the case of DC wiring, connect the wires by matching their polarities to the and marks.

Specications [mm] Table 1 Cylinder Strokes Bore size Stroke 16 15, 20, 25, 30 20, 25 15, 20, 25, 30, 35, 40, 45, 50 32 to 63 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Ambient and uid temperature range 32 to 302F [0 to 150C] Seal material Fluororubber Grease Heat resistant grease Standard stroke See Table 1. Dimensions See below.

Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 1/4, 3/8, 1/2 3/4, 1 1 , 1 2 80 98 126 160 145.5 155 216 241 3 7 5 10 1/4 1/4 1/4 1/4 39.5 43 75 90 50.0 85 48 52 80 90 B24P B25P 67 78 110 140 73 78.5 94.5 4 1 2 1 109.5 680

PF2A712H 75 mm button (SET) Press this button to change to another mode and to set a value. Key-lock function List of outputs button (MODE) Moves on to the function selection mode. Find the diagram of the output required in the table below.

HRSH Series 5.23 Communication Function 5-75 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions Setting/Checking: Slave addresses (MODBUS) 9. Press the [SEL] key once. Setting screen of slave addresses (MODBUS) is displayed on the digital display. PV SV 10. Set slave addresses (MODBUS) with [] key or [] key, and press [SEL] key to enter.

The resistance must be suitable for the characteristic impedance of the cables used for connection and have a combined resistance of 75 ohms or more. 3.9 Identification Code List The following parameters can be changed.

The resistance must be suitable for the characteristic impedance of the cables used for connection and have a combined resistance of 75 ohms or more. 3.9 Identification Code List The following parameters can be changed.

Year Month 2015 2016 2017 2025 2026 2027 T U V D E F Bore Size (mm) Torque 10% (N.m) Jan O TO UO VO DO EO FO Instruction Manual CG1*N25&100-*Z-X2992 Air Reservoir 32 2.9 Feb P TP UP VP DP EP FP 40 4.9 Mar Q TQ UQ VQ DQ EQ FQ 50 11.8 Apr R TR UR VR DR ER FR 63, 80 24.5 Do not service or attempt to remove product and May S TS US VS DS ES FS machinery/equipment until safety

P. 12-6-17 12-6-5 5 Series MHK2 Construction Double acting Single acting @0 e !8 !7 w o Open condition Normally open !9 t y !5 !6 i u q r !1 !0 Closed condition Normally closed !2 !3 !4 Component Parts Material Material Note Note No. q w e No. i o !0 !1 !2 !3 !4 !

AMV AMP Solenoid valve SFE SFE Exhaust port (EA) Supply port (P) Exhaust port (EB) 2. The outside diameter of tubes that have been used at high temperatures or for long periods of time will expand, and in some cases pipe fittings cannot be reattached. Tubes that cannot be attached should be discarded and replaced with new ones. Fig.

P. 12-6-17 12-6-5 5 Series MHK2 Construction Double acting Single acting @0 e !8 !7 w o Open condition Normally open !9 t y !5 !6 i u q r !1 !0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Closed condition Normally closed !2 !3 !