Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 06 (3/4), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Body Size: 50, Thread: F (G), Port: 06 (3/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Body Size: 50, Thread: F (G), Port: 06 (3/4), Option: Standard, Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: F (G), Port: 06 (3/4), Option: Standard, Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: B (PNP; PNP), Option 1: W (w/Lead Wire w/Connecter + Connector Cover), Unit Specifications: M (SI Unit Only)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: D (NPN; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: M (SI Unit Only)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: B (PNP; PNP), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: B (PNP; PNP), Option 1: W (w/Lead Wire w/Connecter + Connector Cover), Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: D (NPN; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: M (SI Unit Only), Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Body Size: 3/4, 1, Port Thread: G, Port Size: 3/4, AVL5000, Option: No Gauge, Voltage: 24VDC, Electrical Entry: D Type DIN Conn. w/M12 Conn., Ind. Light & Suppressor, Air Direction: Right to Left, Button Color: -
Flow Rate Range: 20 to 2000 L/min, Thread Type: G, Port Size: 3/4, Output Specifications: PNP; PNP, Option 1: w/Lead Wire w/Connecter + Connector Cover, Unit Specifications: SI Unit Only, Option 2: -, Calibration Certificate: -