13.5 3 (R) 12 4-1/4,3/8NPT 12 4-1/4NPT VH33 -N02/N03 (Bottom porting) 2 (A) Panel cut dimension 44 2A +0.3 0 1 (P) 3 (R) C +0.5 0 B0.1 4-1/4,3/8NPT 4 (B) Max. panel thickness D (mm) A 3.2 3.2 3.2 B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 type VH300 type VH400 type 8 Panel Mount/Dimensions Series VH (mm) / Panel mount type Dimensions VH41 -N02/N03/N04 VH41 -N06 Scale: 35% 2 (A) 4 (B) 4 (B) 2
/SO2+ 23 1 Lock interlock signal 2 Used for general-purpose output. Note: Set the parameter to allocate a function.
Options: Count (N,n; Inputs: U> (Up) D> (Down) C> (Clear) P> (Preset) Outputs: ON/OFF and Word Comparison 6 7 PneuAlpha Function Blocks 6 6.11 The COMPARE Block Compare two values and when the equation is true the Output will come ON.
H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
Series AM, AMD, AMH, AMG 150 CA AM AMD AMH AMG Thread type (3) Nil Rc F G N NPT Body size Accessory (Option) A With drain cock (1) Note 3) Corresponds to attachment symbols C, D, and J. Select according to the type of threads used on the body. C With N.O. auto-drain D With drain guide (2) 150 250 350 450 550 650 850 With N.C. auto-drain J Note 1) 850 size comes with a ball valve.
Ventilation direction Compressed air outlet Rc 3/8 Compressed air inlet Inspection grill Rc 3/8 G Ventilation air inlet C Ventilation direction F [100VAC specification] Power cord (900) [200 to 240VAC specification] Terminal block J 63 L 20 Drain tube K H 4-13 [200 to 240VAC specification] Power cord outlet Model Port size A J B C D E F G H K L IDU3D IDU4D 246 496 509 87 125 344 23 175 151
Ensure input branch current does not exceed the specification range. 3 Mode No.4 Number of branch Valid port A OFF 16 points per port COM A and B B ON 8 points per port COM A to D Check the connection of UNLIT COM port branch to input unit. 4 COM A-D is not LIT 23 22
Functions and Indications Page 23 Alarm Page 23 Wiring Page 24 Wiring Circuit Page 24 Operation Chart Page 26 DimensionsPage 27 With Flow Rate Adjustment Function Specific Product Precautions Page 29 8 IZF21/31 Series Technical Data *: Static neutralization performance is based on data using a charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S.
EX245-SPN1 16 Valves (16 coils)32 Valves (32 coils) 2 2 4 D 0 1231 0.X byte Valves (16 coils) Valves (32 coils) 0 Valve coils 0-7 Valve coils 0-7 1 Valve coils 8-15 Valve coils 8-15 2 Valve coils 16-23 3 Valve coils 24-31 . 6-2 46 No.EX-OMU0020CN 6.4.
Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com R P 27 30 (2) 7 12.7 VR A 9.2 VH 2 15 (Bracket) 10 VHS 11 Base mounted: SYJA34-M5 14 5 10 Manual override (Non-locking) 2-3.2 (External pilot port) (For mounting) 17 3 (For solenoid valve) 2.5 M3 x 0.5 (Pilot port) A 11 17.5 1.5 21 27 30 28.5 P R 1 (Breathing hole) 13 5 8.6 10 (P , A, R port) M5 x 0.8 23
HOLD BANK1 BANK2 MULTI COUNTER:CEU5 UP Nil D 100 to 240 VAC 24 VDC Output transistor mode COUNT PRESET FUNC. LEFT RIGHT DOWN Nil P NPN open collector output SEL.
[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]
(100) D 6.3 (CN2SW)ON (EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC)OFF (LEC)(EMG+,EMG-) 22 - (LEC) ()LEC6 DC24V 0V Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (LEC)OFF 23 - 7.CN3 1 1 DA CC-Link A 2 2 DB CC-Link B 3 3 DG CC-Link 4 4 SLD CC-Link
E SET HYS k Pa MO D E SET HYS k Pa MO D E SET HYS k Pa MO D E SET HYS (72.4) Attached washer (63.6) (60.1) Attached washer SMC SMC SMC SMC 10.2 V V V V V 28.8 8.5 21 10 9 8.5 9 81 Vacuum port (V port) Note 4) 107 (M5 x 0.8) Note 1) The above dimensions are for ZZQ1-BSB.
E SET HYS k Pa MO D E SET HYS k Pa MO D E SET HYS k Pa MO D E SET HYS Misc. (72.4) Attached washer (63.6) (60.1) Attached washer SMC SMC SMC SMC 10.2 V V V V V 28.8 8.5 21 10 9 8.5 9 81 Vacuum port (V port) Note 4) 107 (M5 x 0.8) Dimensions Note 1) The above dimensions are for ZZQ1-BSB.
KE AS-FG Dimensions AS-FP H1 AS-FM (Hexagon width across flats) AS-D Applicable tubing O.D. d AS-T H2 ASP (Hexagon width across flats) L4 L3 ASN L5 AQ ASV D1 L2 AK VCHC M M L1 ASR ASQ Metric Size Inch Size L4 Max. L5 (1) L5 (1) L4 Max. Weight (g) Weight (g) Panel-cut dimensions Panel-cut dimensions H1 H2 d D1 L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M Model Model Min. Max. 34.4 Min.
-2No.PF-OMO0004CN-E / 1 1.5 *3) 1 1 [] -3No.PF-OMO0004CN-E () () () N2 () -4No.PF-OMO0004CN-E () * UL UL1310 2 UL1585 2 ,30[Vrms]42.4[V ] 2 UL , 100 N2 050 () JISB 8392-1 1.1.21.6.2 -5No.PF-OMO0004CN-E * FG (49 N () ,IN () () -6No.PF-OMO0004CN-E * 6 33 () 30 m DC(-)() -7No.PF-OMO0004CN-E * () () CE 050 -8No.PF-OMO0004CN-E * 10 /23% 3 * OUT * 23 -9No.PF-OMO0004CN-E PFMB
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Q1 5 4 () 1) () Q2 1)+COM (4) 7) (2)1U (3)J1,J2, Q2 (11) (P ) L L 0.3m 0 (M5x0.8) LO L 2 4 3 6 (5) 5 4 2) B (12) (2):1U 2)(3)Q1 8) (3)Q2 Assy N C 3) ) (6) ( D [kPa] (2):3M EA NPN2 9) 8) (PD) EB PNP2 0 to -100 EC NPN1 + S EE PNP1 + C FA NPN2 D FB PNP2 -100 to 100 8)VQ100 Ass yP.41 FC NPN1 + FE PNP1 + (3)Q2 (4)LO 9)(3)J1,J2Q2 P.6 (3)C 4) F 3) ZFC 4