SMC Corporation of America
Elite Part Number Search
Search Results "PF2D504-11-2"

: 1.3 × 10-11, Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: None, Heater Yes/No: None

: 1.3 × 10-11, Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: None, Heater Yes/No: None

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 16, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 16, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: [Other] CF, Flange Size Nominal: 16, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 16, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, left, Temperature Range(°C): 5 to 60,

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 150, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: [Other] CF, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: [Other] CF, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch

(valve closed), Seal Material: FKM (1349-80), Amount of leakage(Pa·m3/s): 1.3 × 10-10 (FKM) / 1.3 × 10-11 (FKM) (internal/external)

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 150, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch