: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Head Cover Port Position: 90
Model Metric size Inch size 4 stations 6 stations 8 stations 10 stations pcs. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Length 38 62 72 90 104 114 135 140 78 111 119 147 179 191 236 277 Hexagon nut Flat washer pcs. pcs.
23 21 56.2 50 ASP530F-N03-11S-X369 31.6 43.1 20.8 3/8 18.5 ASP630F-N04-11S-X369 24 33.6 47.9 61.8 20.8 NPT1/2 NPT1/4 17 28.6 25.6 70.3 ASP630F-N04-13S-X369 1/2 23.81 21.7 35.2 49.5 63.1 21.8 XTO Series T2 D 2-T1 L3 L2 L1 Model T1 T2 D L1 L2 L3 XTO-2571-02 Rc1/4 52 52 21 57 XTO-2571-03 Rc3/8 XTO-1239-02 Rc1/4 84 80 37 79 XTO-1239-03 Rc3/8 Rc1/4 XTO-1239-04 Rc1/2 XTO-1719-06 Rc3/4 98 98 40 90
Controlled flow Free flow Model Port size Weight (g) Sonic conductance dm3/(sbar) Sonic conductance dm3/(sbar) Critical pressure ratio Critical pressure ratio Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 340 0.94 250 0.7 115 1/4 1/4 810 2.3 0.35 0.2 810 2.3 130 3/8 1/4 1670 4.6 1670 4.6 225 3/8 1/2 Note
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
66 361. 5 6.5 361. 15 M8 x 1.25 x 10 12-CY3R40 L Model LD M MM N PW Q QW T TC W WP X Y Z 12-CY3R15 53 4.3 5 161. 18 191. 171. 25 161. 18 54.5 194 184 32 M4 x 0.7 12-CY3R20 62 5.6 5 171. 17 20.5 201. 40 191. 22 641. 107 195 38 M4 x 0.7 12-CY3R25 70 5.6 6 16.5 20 21.5 22.5 40 21.5 28 721. 117 105 43 M5 x 0.8 12-CY3R32 76 71. 7 18.5 26 241. 281. 50 271. 35 791. 130 116 54 M6 x 1 12-CY3R40 90
F (C) Correction factor 58.0 (0.4) 0.9 1.06 72.5 (0.5) 36 to 77 (2 to 25) 0.93 1.02 87.0 (0.6) 86 (30) 0.96 1 101.5 (0.7) 90 (32) 1 116 (0.8) 0.99 95 (35) 1.03 130.5 (0.9) 0.98 104 (40) 1.06 145 to 232 (1 to 1.6) 0.92 113 (45) 1.09 1 Refrigerant R407C (HFC) Series IDF100FS/125FS/150FS Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 140F (60C) (Max. ambient
Free flow Controlled flow Model Applicable cylinder bore size (mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 340 5.2 250 3.8 20, 25, 32, 40 115 32, 40, 50, 63 810 12.3 810 12.3 130 40, 50, 63 80, 100 1670 25.5 1670
(0.5) AC60* 98 101 131 Proof pressure 225 psi (1.5 MPa) 60 (0.4) Operating pressure range 30 to 150 psi (0.2 to 1 MPa) A1 A2 A3 45 (0.3) Ambient and fluid temp. 32 to 140F (0 to 60C) 30 (0.2) 113 20 122 37 61 1(P) to 2(A) Effective area (mm2) 132 24 141 49 76 2(A) to 3(R) 15 (0.1) 1.14 (0.64) 1.63 (0.74) 2.21 (1.00) 4.19 (1.90) 4.06 (1.84) Weight manual/solenoid lb (kg) 0 15 30 45 60 75 90
BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) Operating Parameters Operating pressure Gas Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45 psig (0.3 MPa) 90
J K l .. oN D P Q W X Z ..J (mm) 50 89 55.5 26 20 64 10.5 M1Bxl .5 B6 7 17 33.5 50 6.6 11 Depth 8 1/4 10.5 71 28.5 19 4" 80 112 68.5 32.5 25 98 12.5 M22xl .S 132 6 22 43.5 77 11 17.5 Depth 13.5 3/8 16 104 35.5 26 65.5 83 94.5 81 26 20 n 10.5 Ml8xl .5 103 7 17 33.5 60 90 14 Depth 10.5 1/4 15 84 28.5 19 55.5 High Magnetic Field Resistallce Sellies COQ2BP Foot Mount: COQ2LPO-OOM-OO H Thread
(mm) Bore size A D F GA GB H LB LC LH LS LT LX LY LZ MM NA NB NN S X Y Z 10 15 4 8 8 5 28 15 4.5 9 60 1.6 24 16.5 32 M4 x 0.7 12.5 9.5 M8 x 1.0 46 5 7 86 16 15 5 8 8 5 28 23 5.5 14 65 2.3 33 25 42 M5 x 0.8 12.5 9.5 M10 x 1.0 47 6 9 90 Rod flange (F) CJ2YF Bore size Stroke Head cover port location Z Mounting nut Cover surface Rod end nut Piping port 2 x M5 x 0.8 GB NN GA C MM D B 0 0.3 FB
& Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89 80 85 90
x 15 B 6.5 8 9.5 9.5 11 11 14 14 GP 20 27 33 39 44 55 65 83 95 HB 10.5 14 17 21 23.5 29 36 45 51 C 3.2 4.2 5.2 5.2 6.5 6.5 8.2 8.2 GW 18.5 25.5 31.5 37.5 42.5 53.5 63.5 81.5 93.5 CB 2 2 2 3 3 3 5 5 5 H 19 26 32 39 44 55 67 85 97 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 Model 12-CY3R6 12-CY3R10 12-CY3R15 12-CY3R20 12-CY3R25 12-CY3R32 12-CY3R40 12-CY3R50 12-CY3R63 L 34 38 53 62 70 76 90
retraction When the cylinder is extended KA: T-slot for hexagon bolt 4 x M K KB KC 6-K (6 positions) 10 10 M12 x 1.75 M10 x 1.5 M8 x 1.25 M Bore size Standard stroke (mm) GB D A 170 140 10 10 38 38 36.5 E B F KC 11 11 8.7 120 X T V 1/4 1/4 1/8 40 P 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C M6 M6 M5 18.5 KA KB 100 63 30, 50, 75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90
10 4.5 J depth 1.5 3 6 +0.030 0 10 9.5 4 Section AA B D Mounting base side +0.030 0 Q QL depth 1.5 3 11-/22-MXP10-20 Without magnet and switch rail Max. 2.5 2 x M2 x 0.4 depth 3 8 2.5 4.7 15 15 L 6 x M3 x 0.5 depth 4 2 x M3 x 0.5 depth 3.5 (mm) G H J K L M N Q QL S V W Z Model 11-/22-MXP10-10 8 32 52.4 20 20 21 6.5 32 14 10 44 40 60 11-/22-MXP10-20 20 50 82.4 36 36 39 7.5 50 20 20 74 65 90
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Change of electrical entry (Orientation) After separating terminal block and housing, the cable entry direction can be changed by attaching the housing in the desired direction (4 directions in 90 increments). In the case of w/ indicator light, avoid damaging the light with lead wire. Precautions Plug a connector in or out vertically, never at an angle.
VCC TQ 621 A VNC Series Threaded Type/Port size: 10A, 15A, 20A, 25A K L Pg9 N P Applicable cable O.D. 6 to 8 F (Air operated) J (External pilot solenoid) Pilot port 12(P1) 2 x (Back side 10(P2)) 4 x M 8 1 Light/surge voltage suppressor (For DZ) Manual override (Non-locking push type) P1 D S Q E Bracket 15 H A R B C Main port 1(A) [Back side 2(B)] Port size: refer to table below A 63 63 80 90
R Pilot port 12(P1) Indicator (Option) 1 8 2 x (Back side 10(P2)) VNA P1 4 x P S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80 90