Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Individual Item, Operating Temperature Range(°C): 5:50~, Combination of supply valve and release valve: Supply valve (N.O.) / release valve (N.C.), Rated Voltage: 24 V DC, Electrical entry: L-type
Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Individual Item, Operating Temperature Range(°C): 5:50~, Combination of supply valve and release valve: Supply valve (N.O.) / release valve (N.C.), Rated Voltage: 24 V DC, Electrical entry: L-type
Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Mechanical Pressure Switch for Vacuum / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Individual Item, Operating Temperature Range(°C): 5:50~, Combination of supply valve and release valve: Supply valve (N.O.) / release valve (N.C.), Rated
Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Mechanical Pressure Switch for Vacuum / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Individual Item, Operating Temperature Range(°C): 5:50~, Combination of supply valve and release valve: Supply valve (N.O.) / release valve (N.C.), Rated
Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Mechanical Pressure Switch for Vacuum / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Individual Item, Operating Temperature Range(°C): 5:50~, Combination of supply valve and release valve: Supply valve (N.O.) / release valve (N.C.), Rated
Tightening the threaded portion of an M3, M5 or M6 fittings 1) M3 First, tighten it by hand, then give it an additional 1/4 turn with a wrench. 2) M5 and M6 First, tighten it by hand, then give it an additional 1/6 turn with a wrench. Mounting Caution 1. Check tubing for damage before installing. Confirm model size, etc. 2.
0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 A M5 M5 M5 2 1 4 R 2 1 0.11 0.16 Weight (kg) (1) 0.19 0.25 0.35 0.55 0.75 1.5 2 4 Hysteresis (2) 1% F.S. 2.5% F .S. 3% F .S. 5% F .S.
0.8 VEX NPT 1/8 NPT 1/8, M5 x 0.8 4 One-touch fitting AMR R 1/8, M5 x 0.8 6 One-touch fitting 5/32" One-touch fitting NPT 1/8, M5 x 0.8 ITV 1/4" One-touch fitting JIS Symbol M5 x 0.8 female thread is cut inside the pipe.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C4L (ø4 One-touch Fitting, Elbow Type)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)