TL D T Conduit terminal DIN terminal VQ7 Conduit terminal with indicator light DL DIN terminal with indicator light Piping Option EVS 0 Bottom ported 1 Side ported Port size Rated voltage VFN 4 Without sub-plate Applicable valve model Port size 1 100 VAC, 50/60 Hz Symbol Option Without sub-plate VP454 2 200 VAC, 50/60 Hz 00 3 110 VAC, 50/60 Hz VP474 4 220 VAC, 50/60 Hz (10A) 3 8 (15A
Type 2 VNC 15A 1 1 1 A T Actuators Manual override Valve size Valve type Port size Rated voltage Symbol Nil Air operated type Port size Rc Valve size 1 Orifice size (mm) Symbol 1 2 4 2 200VAC, 50/60Hz 1 100VAC, 50/60Hz Symbol N.C. 0.5MPa N.O. 1MPa N.C. 1MPa 3 110VAC, 50/60Hz 4 220VAC, 50/60Hz 1 6A 8A 10A 10A 15A 20A 25A 32A 1/8 1/4 3/8 3/8 1/2 3/4 7 5 24VDC 6 12VDC 7 240VAC, 50/60Hz 15
(with no condensation) Standards and regulations CE marking, RoHS Fluid contact materials PPS, FKM, Brass Port size 3/8 (10A) 1/2 (15A) 3/4 (20A) 1 (25A) Weight (Body)*4 Approx. 335 g Approx. 395 g Approx. 515 g Approx. 675 g *1 Refer to the Applicable Fluids List on p. 20. *2 When fluids with high temperature are used, the available pressure range will be reduced.
Install a Ground Fault Circuit Interrupter(GFCI) to the power supply (Prepare by yourself) [Sensed current: 30mA and below, Rated current 10A (Rated current 15A for IDF75E)] Specification of power cable Prepare following power cable.
Air Flow Capacity Air flow calculated with correction factor (see the Chapter 7-2) Power consumption (Note 4) 1100W 1870W 2490W 3630W Electric spec Current consumption (Note 4) 10.0A 4.8A 8.2A 10.9A 15.9A Applicable earth leakage breaker capacity 15A 10A 15A 20A 30A (sensitivity current: 30mA) (Note 5) Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) GWP:2088 (Note 6) 13.70.4oz
VXA213 VXA223 VXA224 VXA225 VXA226 VXA223 VXA224 VXA225 VXA226 VXA226 0.5 1.0 1.0 170 0.5 1.0 0.6 0.2 0.1 1.0 0.6 0.2 0.1 0.1 4.5 15 0.61 2.5 10.45 0.75 1 4 250 (8A) 26 41 46 15 26 41 58 58 1.1 1.7 1.9 0.61 1.1 1.7 2.4 2.4 3.3 6.4 8.8 2.5 3.3 6.4 11 11 0.50 0.40 0.40 0.45 0.50 0.40 0.38 0.38 1.1 1.8 2.3 0.75 1.1 1.8 2.8 2.8 6 8 1.5 0.4 340 10 4.5 6 8 250 1.0 3 8 (10A) 340 0.4 10 10 1 2 (15A
[Sensitivity of leak current: 30mA or less, Rated current: 15A] Specifications of power supply cable Prepare the following power supply cable. [IDFA100F, 125F] Power supply cable: 3.5mm2(12AWG) or larger, Cable outside diameter Approx. 14 to 18mm, 4 cores (including ground) Approx. 0.6m is necessary to route the internal wiring of the product.
Do not retrofit the wiring of the dryer and the power supply line. 9-2 Specifications of the GFCI Dryer model number Specifications of GFCI IDFB22E-11-R Rated current: 15A, Current sensitivity: 30mA IDFB22E/37E-23-R IDFB55E/75E-46-R Rated current: 10A, Current sensitivity: 30mA 9-3 Cautions for handling the GFCI 1) When the breaker is tripped, cut off the power supply and contact the nearest
by pressure Atomizing of liquid Stirring of liquid Prevents sticking of liquids Features 2 Process Pump Automatically Operated Type (Internal Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 0 PA3000 Option Body size Nil N Body only With silencer 3 5 3/8 standard 1/2 standard For AIR EXH: AN200-02 Liquid contact body material Connection port size 03 04 06 3/8 (10A): PA3 1/2 (15A
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel
Install an Ground Fault Circuit Interrupter(GFCI) to the power supply (Prepare by yourself) [ Sensed current: 30mA and below, Rated current 10A (IDU75E-23Rated current 20A , IDU75E-30Rated current 15A) ] Specification of power cable Prepare following power cable.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel
Applicable piping size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 2 2 3 1 2 3 2 3 4 B B C A B C B C D 6 x 4 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 1/4" x 5/32" 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 12 x 10 1/2" x 3/8" 19 x 16 3/4" x 5/8" 25 x 22 1" x 7/8" Dimensions Union Flange: LQ3F Metric Size (S) T P M L2 L2 L1 L1
Stainless steel 316L equivalent / Bronze (CAC) Fluid temperature 183C (steam) or less Low pressure loss Pressure loss Small Pressure loss Large Angle seat structure Current structure Variations Model Orifice diameter [mm] Cv Port size Max. operating pressure [MPa] Body material Fluid Standard High pressure VXB215A D 11 3.5 3/8 (10A) 1 1.6 Stainless steel 316L equivalent, VXB215B E 14 5.4 1/2 (15A
Stainless steel 316L equivalent/ Bronze (CAC) Fluid temperature 183C (steam) or less Low pressure loss Pressure loss Small Pressure loss Large Angle seat structure Current structure Variations Model Orifice diameter [mm] Cv Port size Max. operating pressure [MPa] Body material Fluid Standard High pressure VXB215A D 11 3.5 3/8 (10A) 1 1.6 Stainless steel 316L equivalent, VXB215B E 14 5.4 1/2 (15A
Control unit specifications Air filter (with auto drain/with manual drain) 5m Filtration degree Regulator 0.05 to 0.85MPa Set pressure (downstream pressure) Pressure switch 0.1 to 0.7MPa Pressure adjustment range 1ab Contact (induction load) 125VAC 15A, 250VAC 15A Rated current Air release valve (single only) 0.15 to 1.0MPa Operating pressure range Options AXT502-9A (for manifold) AXT502-
has a built-in solenoid valve, it cannot be used for transfer of flammable fluids. 17-5-146 17-5-147 Process Pump Automatically Operated Type (Internal Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 0 PA3000 Option Body size Nil N 3 5 Body only With silencer 3/8 standard 1/2 standard For AIR EXH: AN200-02 Port size Material of body wetted areas 03 04 06 3/8 (10A): PA3 1/2 (15A
The model HEC012 Thermo-Con must be installed downstream of a Circuit Breaker (UL 489 Listed and IEC 60947-2 Approved) rated 15A or less. 7.2.3 Grounding Be sure to provide protective ground, which must be class D for Japan (ground resistance of 100ohm or less). PE line of the power supply cable is available for grounding.
Choice of seal materials NBR, FKM I N OUT Variation (Common specifications for solenoid valve and air operated valve) Series Port size Thread type Type of actuation Operating pressure range (MPa) Av factor x 10-6m2 Bracket Electrical entry (in case of a solenoid valve) 110 0.5 Conduit terminal Bracket on the left side 3 / 8 (10A) 85 1 30 1.6 SGC2 155 0.5 1 / 2 (15A) DIN terminal 116 1
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 03 04 06 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) PA5000 Diaphragm material Thread type 1 2 PTFE NBR Nil T Rc NPTF G NPT F N T, F, N are options.