80 86 35 18 35 25 2 36 17.5 72 98 57 1/2 148.5 121.8 101 M5 x 0.8 5.4 to 7.5 C J G5-S CCVS2-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 57 1/2 148.5 103.9 101 CCVS3-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 57 1/2 148.5 103.9 101 CV CCVS0-S 45 80 86 35 25 36 17.5 88.2 72 98 57 1/2 CCVL02-G-S 66 107 116 50 24 40 28 1 40 27 115 100 62 3/4 180.5 124.9 135 MVGQ CCVL1-G-S 66
Electrical entry VQD G Body style VZS Coil voltage Lead wire length 0.6m Grommet 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Lead wire lenghth 1.5m 1 2 3 4 5 6 5: Plug lead Sub-plate VFS H VS VS7 Function Standard (1W) Low wattage (0.5W) External pilot Seal Y R (1) (2) 0 1 Metal seal Rubber seal Applicable to DC specification.
G5-S CCVS2-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 1/2 148.5 57 103.9 101 CCVS3-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 1/2 148.5 57 103.9 101 CV CCVS0-S 45 80 86 35 25 36 17.5 88.2 72 98 1/2 57 CCVL02-G-S 66 107 116 50 24 40 28 1 40 27 115 100 3/4 62 180.5 124.9 135 MVGQ CCVL1-G-S 66 107 116 50 24 40 28 2 40 27 100 3/4 80 135 180.5 132.8 135 M6 x 1 10.5 to 12.5
Vacuum pressure Theoretical lifting force Horizontal lifting force [N]Safety factor 1/4 [kPa] [N] 1 cup gripping -50 40.2 10.0 2 cups gripping -67 53.8 13.4 3 cups gripping -73 58.7 14.6 (Calculated by W = P X S, S = r2, r = 32 / 2. Refer to 3.3 How to calculate theoretical lifting force for the detail.)
Work piece weight (kg) Work piece weight (kg) 10 10 5 5 1 1kg 1 0.25kg 0.1 10 20 40 0.1 5 10 20 30 Transfer speed (m/min) Transfer speed (m/min) 32.5m/min 12m/min Procedure3 Confirmation of allowable lateral load MIW12 MIS12 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) 1.
min. 1 (between case and cable) 1000V AC for 1 min.
P V 1069 Series ZL112 Vacuum Pressure Switch Unit/Digital Pressure Switch for Vacuum: ZSE30A-00---X505 How to Order ZSE30A 00 X505 Output specifications Option 2 (Operating manual specifications) Output Analog output Type NPN PNP NPN PNP NPN NPN PNP PNP Nil Operating manual (Leaflet) Without operating manual Symbol Voltage Point 1 1 2 2 1 1 1 1 Current Y N P A B C D E F Option 1 (Connector
Dimensions HF2-BFA, HF2-BFB, HF2-BFD HF2-BFC Model P A B C D E G J HF2-BFA30 1/4, 3/8 53 151.1 21.5 26.5 30 35 26.5 HF2-BFB30 1/4, 3/8 53 151.1 21.5 26.5 30 35 26.5 HF2-BFC30 1/4, 3/8 53 126.4 21.5 26.5 30 35 26.5 HF2-BFD30 1/4, 3/8 53 151.1 21.5 26.5 30 35 26.5 HF2-BFA40 1/4, 3/8, 1/2 70 180.9 25.5 35.5 38.4 40 35.5 HF2-BFB40 1/4, 3/8, 1/2 70 180.9 25.5 35.5 38.4 40 35.5 HF2-BFC40 1/4, 3
Part name Material Qty Remarks 1 Cassette POM,Stainless steel304 2 Blue 2 Body PBT 1 Red 3 Seal NBR 2 4 Valve HNBR 1 5 Valve guide Brass 1 6 Rod Brass 1 7 Push Button POM 1 Red 8 Spring Stainless steel304-WPB 1 9 Push nut Stainless steel304 1 Rc thread with a push button guardKEC No.
Doc.No.IZ-OMK0015D PRODUCT NAME IONIZER MODEL/Series IZS31 series 1 Doc.No.IZ-OMK0015D Contents Safety Instructions . 3 1. Installation Method . 9 1-1. Installation of Ionizer Body . 9 1-2. Installation of Feedback Sensor/Auto Balance Sensor [High-precision type] .11 1-3. Installation of Auto balance sensor [Body-mounting type] . 12 1-4. Cable Connection . 13 2.
Series Appearance Class Metric size Inch size 1/4" 3/8" None 1/8" 1/2" 3/4" 1" 6 8 10 12 19 1/8" 1/4" 3/16" 3/8" 1/2" 3/4" 1" 25 4 3 1 2 3 Male 4 5 Connector LQ1H P.4 6 1 2 3 Female 4 5 P.5 6 1 2 3 Male 4 5 Elbow LQ1L P.6 6 1 2 3 Female 4 5 P.7 6 1 2 3 Male 4 5 Run tee LQ1R P.8 6 1 2 3 Female 4 5 P.9 6 Note) Basic size With reducer Features 2 Series LQ , LVN, TL/TIL 1 2 Port size Tubing
() 200 ms() 1.5 s() 0.5F.S. 1 digit 3+1/2 7 2 (/)5 /1s OUT1ON ()OUT2ON () IP40 050 -1060 () 3585R.H.() AC1000 V 1 50 M (DC500 V ) 0.5%F.S.(25 ) 5P 4P PBTPBT 30 g() CEUL/CSA 12 5 2 -32No.IZ*-OMU0031 (ZS-28-A) 2 0.2 mm 0.58 mm 1.12 mm 4.1 -33No.IZ*-OMU0031 0.56 mm R R2 2 (n ) <> <> 31Xn +3.5X(n -1) 31Xn +3.5X(n -1) -34No.IZ*-OMU0031 Revision history A 4-14-1, Sotokanda
HEC ii CONTENTS CONTENTS Pages 1 Preparation for Communication -1-1 2 Specifications of Communication Method -2-1 3 Communication Format -3-1 3.1 Control code used for communication -3-1 3.2 Command code list -3-1 3.3 Communication procedures and format -3-2 3.4 Calculation of checksum -3-3 4 Details of Communication format -4-1 4.1 Temperature setting (without writing EEPROM) -4-1 4.2 Reading
PAX PB Model %# & 0 & VXA3114 VXA3124 VXA3134 VXA3224 VXA3234 VXA3244 , 1 , / , 1 , / , 1 , / , / . 1 , / . 1 , / . 1 ,!* )!).)!)./ Material 17-3-101 6 The VX series will be revised shortly. Series VXA31/32 Common (C.O.)
MB1 CA2 CS1 CS2 a (1) BJ-1 is a set of a and b. BJ4-1 (Switch bracket: White) BJ5-1 (Switch bracket: Transparent) (2) BMA2-A(S) is a set of c and d. Band (c) is mounted so that the projected part is on the internal side (contact side with the tube).
OFF Note 1: ON/OFF 50 ms flashing Note 2: ON 200 ms single flash, OFF 1 s Note 3: ON/OFF 200 ms double flash, OFF 1 s Note 4: ON/OFF 200 ms triple flash, OFF 1 s Note 5: ON/OFF 200 ms flashing -15No.EX-OMV0023-A Switch setting The switches should only be set with the power supply turned off.
Breaker Operating Characteristics Common for all models 4 h 2 h 1 h 5 s 10 s 20 s 30 s 1 min 2 min 4 min 6 min 10 min 14 min 20 min 30 min Max.
Back page 1 Series IDK Specific Product Precautions 1 Be sure to read this before handling. Refer to back page 1 for Safety Instructions. Design Mounting Caution Caution 1. Do not use the moisture control tubes bundled together. Otherwise, the performance may be decreased. 1. Use the moisture control tube without lubrication. 2.
Material MHK2-12 MHKL2-12 MHK2-16 MHKL2-16 MHK2-20 MHKL2-20 MHK2-25 MHKL2-25 16 17 18 19 CR FKM Si Rod seal Piston seal NBR KT-MHK12 KT-MHK16 KT-MHK20 KT-MHK25 Piston retainer Tube seal P3318413 P3318413-1 P3318413-2 P3318405 P3318405-1 P3318405-2 P3318313 P3318313-1 P3318313-2 P3318305 P3318305-1 P3318305-2 P3318213 P3318213-1 P3318213-2 P3318205 P3318205-1 P3318205-2 P3318113 P3318113-1
Elbow connector Union nut Sleeve Body Swivel elbow connector Piping Method Equivalent tightening torque [Nm] KF-04 1/6 to 1/3 3 to 7 KF-06 1/6 to 1/3 3 to 7 KF-08 1/6 to 1/3 3 to 7 KF-10 1/6 to 1/3 5 to 10 KF-12 1/6 to 1/3 5 to 10 Fitting size Appropriate tightening rotations Caution 1. Insertion of tube 1) Take a tube having no flaws on its periphery and cut it off at right angles.