Rated Flow Range: 10 [0.2 to 10 (5) L/min], Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Unit Specification: w/Units Selection Function, Operation Manual: None, Calibration Certificate: None, Lead Wire: w/o Lead Wire with Conector, Option: None
Please contact us for the latest version.sales@ocaire.com, N, "REGULATOR
Special applications include (10-) clean room compliant, (20-)copper-free, fluorine-free, and (21-) clean room compliant, copper-free, fluorine-free and silicon-free.Direct operated precision regulator, Sensitivity: within 0.2%F.S., 3 types of set pressure allow more freedom in designing a circuit, Repeatability: within ±1%F.S., Backflow function available, N, "REGULATOR
Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Model: 31, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: N (SS/Ag, Seals: FKM, Class H), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: G (Grommet), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 1 (1.5mm), Style: 2 (N.O., Single Unit), Option: N (SS/Ag, Seals: FKM, Class H), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: N (SS/Ag, Seals: FKM, Class H), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 1CN (1 + C + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: CN (C + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Model: 3 (10-SY3000), Actuation: 1 (2 Position Single), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate)
Model: 3 (10-SY3000), Actuation: 2 (2 Position Double), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate)
Model: 3 (10-SY3000), Actuation: 1 (2 Position Single), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate)
Type of Actuation: 1 (2 Position Single), Manifold Type: 60 (Body Ported Plug-in Cassette), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)