Magnet: D (Built-in Magnet), Mounting: B (Basic), Style: A (Air Cushion), Bore Size: 40mm, Thread: TN (Rubber Bumper: NPT 20 to 100; Air Cushion: M5: 20, 25; NPT: 32 to 100), Seal Material: V (FKM Seals, Fluororubber), Stroke: 300mm
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Style: A (Air Cushion), Bore Size: 40mm, Thread: TN (Rubber Bumper: NPT 20 to 100; Air Cushion: M5: 20, 25; NPT: 32 to 100), Seal Material: V (FKM Seals, Fluororubber), Stroke: 300mm
Size: 30, Model: D (Filter Regulator + Mist Separator), Thread: N (NPT), Port Size: 03 (3/8), Float Type Auto Drain: w/o Auto Drain, Attachment: V (Pressure Relief 3-port Valve), Option 1: None, Option 2: None, Option 3: Z (Product Label: psi, Caution Label for Bowl psi/°F; Pressure Gauge: MPa/psi Dual Scale)
Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure
Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure
D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
D [With Individual Release Pressure Supply (PD) Port Type]
Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure
, Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
Mounting Screw is Attached)], Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type]
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure
Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)