Made to Order: Standard, Body Size: 1/2, Max. Operating Pressure 1.6 MPa, Thread Type: NPT - Made to Order, Port Size: 1/2, Option: None, Semi-standard: Display Units for Product Nameplate & Pressure Gauge: psi

AS: AS, Body Size: 1/2 Basis, Style: Universal, Control Method: Meter-in, Thread: NPT, Port Size: 1/2, Applicable Tube OD: 1/2", Option: Sealant, Lock Nut: -

Size: 40, Thread Type: NPT, Port Size: 1/2, Accessory: No, Case options: Metal case, Drain outlet options: Drain guide (1/4 female thread), Flow direction options: Left > Right, Recommended flow rate(L/min (ANR)): 300

Size: 40, Thread Type: NPT, Port Size: 1/2, Accessory: No, Case options: Metal case, Drain outlet options: With drain cock, Flow direction options: Right → Left, Recommended flow rate(L/min (ANR)): 300

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Exhaust Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Exhaust Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Exhaust Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: -, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type & Direction: Direct Side

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: -, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type & Direction: Direct Side

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Panel Mount, Plumbing

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Panel Mount, Plumbing

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Exhaust Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Panel Mount, Plumbing

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: -, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 79.34, Effective Sectional Area Class(mm2): Up to 80, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Panel Mount, Plumbing Type & Direction: Direct

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 64.58, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Panel Mount, Plumbing

Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Exhaust Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 64.58, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Panel Mount, Plumbing