Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)
This is a legacy product, and replaced byAS2201F-N01-07S, INVALID P/N (SGL P/N SYST *LQA, AIRLINE EQUIPMENT, AS***F 1/8INCSTANDARD (NPT), .03968 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: K (Operation Manual, Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Nozzle Diameter: 10 (ø1.0mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)
225 psi (1.5 MPa) 60 (0.4) Operating pressure range 30 to 150 psi (0.2 to 1 MPa) A1 A2 A3 45 (0.3) Ambient and fluid temp. 32 to 140F (0 to 60C) 30 (0.2) 113 20 122 37 61 1(P) to 2(A) Effective area (mm2) 132 24 141 49 76 2(A) to 3(R) 15 (0.1) 1.14 (0.64) 1.63 (0.74) 2.21 (1.00) 4.19 (1.90) 4.06 (1.84) Weight manual/solenoid lb (kg) 0 15 30 45 60 75 90 105 120 135 150 Weight manual lb (kg
T1 = V/a1 = 1000/2500 = 0.4 [s], T1 T2 T3 T4 11LEJS T3 = V/a2 = 1000/2500 = 0.4 [s] L: Stroke [mm](Operating condition) V: Speed [mm/s](Operating condition) a1: Acceleration [mm/s2](Operating condition) a2: Deceleration [mm/s2](Operating condition) T = T1 + T2 + T3 + T4 [s] L 0.5V(T1 + T3) V 25AT2 = T1: Acceleration time and T3: Deceleration time can be obtained by the following equation
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -