Non contact style sensor for applications requiring confirmation of work present for machining operations. 3.8-1 Air Catch Sensor ISA How to Order Individual/Centralized Wiring ISA 01 PSE Option ZSE4 ISE4 Applicable to DIN rail Output specifications With bracket B ZSE5 ISE5 NPN open collector 1 output PNP open collector 1 output 11 With gauge G 15 Order DIN rail separately.
Check Valve Series AK Large flow capacity Low cracking pressure: 0.02 MPa A wide variation of models Model Model Effective area (mm2) Port size Weight (g) 1 8 AK2000-01 25 105 1 4 AK2000-02 27.5 100 1 4 AK4000-02 47 155 3 8 AK4000-03 85 150 1 2 AK4000-04 95 140 3 4 AK6000-06 200 345 AK6000-10 230 315 1 Specifications AS Fluid Air Proof pressure 1.5 MPa ASP Maximum operating pressure 1 MPa
Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Mass (g) Model IN OUT OUT EXH AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 M5 x 0.8 2 2.8 25 1 8 4 5.8 45 1 8 25 25 110 1 4 35 40 105 1 4 40 42 215 8 3 60 70 205 1 2 105 115 690 3 4
Meter-out: Gray Meter-in: Light blue Thread type Nil R N NPT G G Stud position A Right side B Left side Applicable tubing O.D.1 Stud position left/right is defined with hexagonal socket visible and knob facing upward.
For vacuum/ compound pressure ISA2 ZSE30A 01 N M Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.
Symbol Stations 01 Manifold direct mounting type 1 station 1 12 12 stations Note) N B: D-sub connector 26 pins With mounting nut No. 10-32 UNF (Inch size) Note Up to 24 solenoids possible.
2 3 Rc,F N IR1000G33-2-01 G33-P2-N01-X30 IR1010G33-4-01 G33-P4-N01-X30 IR1020G33-10-01 G33-P10-N01-X30 011/84 Rc NNPT FG 00.0050.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R101BG M AX.
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
Free flow Controlled flow Model Applicable cylinder bore size (mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 340 5.2 250 3.8 20, 25, 32, 40 115 32, 40, 50, 63 810 12.3 810 12.3 130 40, 50, 63 80, 100 1670 25.5 1670
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A AS Series Speed Controller: Standard Type In-line Type Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
EX500-DXPB: 450 g System Gateway distribution system 2 (128 point) Power supply voltage for input and control Voltage drop may occur to the source voltage supplied from the input unit to the sensor due to the connected unit, power consumption of the sensor or the length of the branch cable.
02 Port size R1/8, M5 x 0.8 R1/4, M5 x 0.8 Piping port: C3604 + electroless nickel plated Pressure sensor: AI203 (aluminum oxide) O ring: FKM + Grease Materials of parts in contact with fluid Without lead wire and M12 connector 88 g 95 g Weight With lead wire and M12 connector 175 g 182 g Cable specifications Nominal cross section area AWG23 Conductor Outside diameter 0.72 mm Material Cross
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from CCW to CW. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) 32 - Origin offset The origin offset means the value of the origin.
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 (CCW) to 1(CW). Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -24-
Compact Direct Operated 2 Port Solenoid Valve for Water and Air SeriesVDW10/20/30 VX2 How to Order Valves (Single Unit) VXD For Water, Air, Vacuum VD W 2 1 1 G 2 01 VXZ VXE Made to Order (Refer to page 244.) Series VXP 1 2 3 10 N.C.
Work piece Vacuum regulator Body size 1 2 3 IRV1000 type IRV2000 type IRV3000 type Leak tester Pressure transducer Solenoid valve Solenoid valve Work piece Vacuum pump IRV Filter Thread type Nil N F Rc NPT G Optional Inspection equipment Port size Solenoid valve Application IRV Work piece Tank Vacuum pump Filter Symbol Bore IRV1000 IRV2000 IRV3000 01 02 03 04 1/8 1/4 3/8 1/2 Flow meter Accessories
With One-touch fitting Port size 01 1/8 02 1/4 03 3/8 04 1/2 Thread type G G thread 1 Flame Resistant (Equivalent to UL-94 Standard V-0) Flat Head Screwdriver Adjustable Speed Controller with One-touch Fitting AS21F-W2D Series Needle Valve/Flow Rate Characteristics Construction AS2201F-G01, AS2211F-G01 AS2201F-G02, AS2211F-G02 e t w u Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa o !
20 g . .. . ~er ~ Zone 10 Distance From Auto Switch Top Face 0 5000 10 15000 20 Welding Current CAl .. ... i1 SO >. . /" /. 40 Sai. Zone ..
100 g *1: The accumulated value will be cleared when the power supply is turned off.