Actuation Type: 3 Position Closed Center, Sealant: Metal Seal, Function: Standard (1W), Voltage: 220VAC 50/60HZ, Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: -, Port Size: -, Thread: -, Composite Symbol: -
(for M12 connector socket) For unused branch connector (OUT). 1: Refer to page 12 for wiring. 2: Refer to page 51 for display -46No.EX-OMT0009 Mounting and Installation Installation Refer to the drawing below. NOTE Tighten the screws while holding the SI unit and the supply/exhaust block assembly so that there is no gap between them.
Specifications . 51 10.3. Wiring . 53 10.4. Safe digital I/O Safe digital inputs . 53 10.5. Safe digital I/O Safe power supply (outputs). 54 10.6. Safe parameter values . 54 10.7. Process data for valves . 59 10.8. Output status unit . 59 10.9. LED indicators . 61 10.10. Production label . 65 2 No.EX##-OMY0004 10.11. DIP Switches . 65 10.12. Block diagram . 68 11.
[F90] Setting of all functions completed : Setting of each function Every time the button is pressed, the display moves to the next function in order of "Setting of each function" on page 51. Set by using the and buttons.
Specifications 51 -1No.TQ0010298-OM003-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Default settings 28 Function Setting [Function selection mode] 28 Default settings 28 F0 Reference condition Unit selection function 29 F1 Setting of OUT1 31 F2 Setting of OUT2 39 F3 Response time 44 F10 Display mode 45 F13 Reversed display mode 46 F20 External input 47 F22 Setting of analogue output 48 F30 Accumulated value hold 49 F31 Orientation correction function 50 F80 Display OFF mode 51
No.PF-OMO0004CN-E // PFMB7201 2 10 13 14 16 16 19 21 [] 25 OU1OUT2 {3 ] 26 28 [] 28 28 F0 29 F1 OUT1 31 F2 OUT2 39 F3 44 F10 45 F13 46 F20 47 F22 48 F30 49 F31 50 F80 OFF 51 F81 52 F90 53 F98 55 F99 56 57 61 62 64 65 65 68 71 -1No.PF-OMO0004CN-E (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic
No.PF-OMM0004-D / / PF3W7## SMC 2 11 13 14 16 17 19 21 24 26 26 F1 OUT1 60 F2 OUT2 36 F3 42 F10 43 F20 47 F22 48 F30 50 F80 51 F81 52 F82 53 F90 54 F98 55 F99 56 57 61 61 65 65 71 79 81 88 -1No.PF-OMM0004-D (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
Installation 15 Installation 15 Wiring 16 Flow Setting 21 Function Setting 24 Default settings 25 F0 Selection of sensor 26 F1 Setting of OUT1 27 F2 Setting of OUT2 35 F3 Response time setting 41 F10 Selection of sub screen 42 F20 Setting of external input 46 F22 Setting of analogue output 47 F30 Storing of accumulated flow 49 F80 Setting of power saving mode 50 F81 Setting of security code 51
Installation 16 Installation 18 Piping Method 19 Wiring 21 Flow Setting 24 Function Settings 26 Default Setting 26 F1 Setting of OUT1 28 F2 Setting of OUT2 36 F3 Response Time Setting 40 F10 Selection of display of sub screen 41 F20 External input 45 F22 Analogue Output Setting 46 F30 Accumulated Value Hold 47 F32 Flow direction setting 48 F33 Close proximity setting 50 F34 Zero-reset setting 51
Installation 19 Piping Method 20 Wiring 22 Setting the Detected Flow Rate 24 Function Setting 26 Default Setting 26 F 1 Setting of OUT1 28 F 2 Setting of OUT2 36 F 3 Response Time 40 F10 Sub screen display 41 F20 External input 45 F22 Analogue Output in free range 46 F30 Accumulated flow value hold 47 F32 Flow direction / reverse flow detection 48 F33 Close proximity setting 50 F34 Zero-reset 51
HRS Series 5.4 Description of the Screen 5-51 DOC1001322 Chapter 5 Display and Setting of Various Functions (1) (2) (3) (4) (5) (6) Serial communication setting Table 5.4-19 Setting of serial communication No.
Discharge pressure alarm (AL21/AL23/AL24/AL26) .5-40 Electric conductivity and alarm setting (AL27) .5-41 5.4.9 Function setting screen .5-43 KEY-LOCK, START-UP operating method, ANTI-FREEZING and WARMING-UP .5-44 Continuing pump operation .5-45 Ambient temperature alarm (AL35) and maintenance alarm (AL36) .5-48 TEMP OUT signal .5-49 Data reset .5-50 5.4.10 Communication setting screen .5-51
AL36: Maintenance alarm (2) Maintenance Operation continues during the alarm By default HRL Series 5.4 Description of the Screen 5-51 HRX-OM-Y098 Chapter 5 Display and Setting of Various Functions TEMP OUT signal 4. Set TEMP OUT signal.
Offset (TEMP OFFSET) function .5-40 Pump operation mode .5-41 Discharge pressure alarm (AL21/AL23/AL24/AL26) .5-42 Electric conductivity and alarm setting (AL27) .5-43 5.4.9 Function setting screen .5-45 KEY-LOCK, START-UP operating method, ANTI-FREEZING and WARMING-UP .5-46 Continuing pump operation .5-47 Ambient temperature alarm (AL35) and maintenance alarm (AL36) .5-50 TEMP OUT signal .5-51
Caution The return to the origin direction of the electric actuator differs according to the electric actuator and the "return to the origin direction" parameter. 51 - .
temperature range [] 5 to 40 Operating humidity range [%RH] 90 or less(No condensation) 28 42 56.4 Motor size Electric specifications Step motor(Servo 24V DC) Motor type Incremental A/Bphase (800 pulse/rotation) Encoder Rated voltage [V] 24 VDC10% Power consumption [W] note5) 22 38 50 Standby power consumption when operating [W] note6) Max.instantaneous power consumption [W] note7) 18 16 44 51
(Even if both IN0 and IN1 commands are turned OFF at reset, the operation commanded at the generation of the alarm will be performed.) 51 - . Operation Examples ..
In position 51 - 6.2 Detail easy mode functions (1)Initial screen Display of the initial screen It displays the initial screen when a controller is connected to the teaching box after the controller is supplied with power regardless of easy mode or normal mode. The version of the teaching box is displayed in the initial screen.
JOG 1 RTN ORIG Start JOG:Move Not at ORIG START SET 51 - b StartStopStopComplete StopSET Complete 4 AX IS. JOG 1 RTN ORIG Done JOG:Move Posn 123.45mm JOG 3 JOG 3 JOG+JOG4 JOG+ JOG-JOG JOG AX IS. JOG 1 RTN ORIG Done JOG:Move Posn 123.45mm (6) LECPA TB Ver2.1*LECPA TESTSET ON a CN5 PLC YESSET AX IS. Check 1 EXT Inp OFF Yes No Check safety!!!