M B For 2 to 10 stations: Both sides Special combination 20 20 stations 20 For 20 stations Note) 25 type is able to use with individual SUP spacer and individual EXH spacer assembly. Refer to page 3-3-14.
D1 L1 D2 L2 A M Nylon 3 Urethane 2.5 3.2 KQ2L23-04 KQ2L04-06 KQ2L04-08 4 6 8 8 10 KQ2L06-10 38.5 19 2 3 11 9.6 7 17 25 26 35 13.5 15.5 10 8 14.5 22 4 10.4 18 4.2 4.2 16 6 KQ2L06-08 12.8 10 20 36.5 11.4 11.4 12 24.5 24 17 8 10 KQ2L08-10 15.2 12 23 39.5 21.6 14.9 20 26 18.5 12 KQ2L08-12 40.5 27 26 10 12 KQ2L10-12 18.5 17 26.5 42 35.2 25.0 29 30 21 12 16 KQ2L12-16 20.9 17 28.5 49.5 50.2 39.7
Use assistance to carry object over 20 kg.
26P Side 420 20 P kit: Flat ribbon cable C8 (For 8) Option Built-in silencer, direct exhaust 20P 1 to 9 stations VQC J kit: Flat ribbon cable SS5Q13SQ130 SQ131 420 20 1 to 8 stations PC Wiring System compatible L3 (For 3.2) L4 (For 4) L6 (For 6) L5 (M5 thread) SQ (2) 460 35 1 to 12 stations L kit: Lead wire Top VQ0 1 to 8 stations 475 20 S kit: Serial transmission Note 1) One-touch fittings
SUP = 0.2 MPa 20 SUP = 0.2 MPa VX2 10 10 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0 0 10 30 40 50 20 60 VX3 10 20 Discharge rate (l/min) Discharge rate (l /min) VXA Selection from Flow Characteristic Graph (PA3000) VN Required specifications example: Find
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Clip Circuit with light PR plate qChanging the piping direction from in-line to perpendicular (port on the valve) is possible on the VQZ100 series. Follow the steps below to change piping direction: Remove the fitting clips that hold the fitting and port plug in place.
mA 120 3 0 to 20 mA 5 1 to 5 V 67 k 10 k 6 0 to 10 V 12 V 7 4 to 20 mA 120 8 0 to 20 mA Symbol Symbol B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) Body size Port size Rc Option Applicable pilot valve (4) Mounting Port 1(P), 2(A) Port 3(R) 00 M5 00 M5 01 00 01 02 00 02 03 04 M5 01 02 02 03 04 04 06 10 10 12 14 20 Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Valve Mounting VS After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.
VV5K3-20-06 VV5K3-40-06-M5 Common SUP/Common EXH VK Type 20: Body ported (A, B port top ported) Applicable solenoid valve VK3120M5 VK312001 VK332M5 VK33201 How to Order A port: Rc 1/8, M5 x 0.8 VZ VV5K3 20 05 A, B port Rc 1/8, M5 x 0.8 VK3120 Thread type VF VK332 Valve stations Nil 00F 00N 00T Rc 01 1 station Applicable blanking plate assembly VK3000-7-1A VFR G NPT 20 20 stations R port:
VV5K3-20-06 [Option] Note) CE-compliant: For DIN terminal only VV5K3-40-06-M5 Common SUP/Common EXH How to Order Type 20: Body ported (A, B port top ported) 20 05 VV5K3 Applicable solenoid valve VK3120--M5(-Q) VK3120--01(-Q) VK332--M5(-Q) VK332--01(-Q) A port: Rc 1/8, M5 x 0.8 A, B port Rc 1/8, M5 x 0.8 VK3120 Valve stations VK332 Thread type Q CE-compliant Nil CE-compliant 01 1 station
19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM (Based on IEC529) Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring (Refer to the connector wiring diagram.)
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Auto switch: (for main exhaust valve) Heater: 23 Series XLD, XLDV High Vacuum Angle Valve Dimensions (mm) 1in=25.4mm (b) XLD/Air operated type E C D E Fn (KF flange) Fd (K flange) (a) C E (c) B A G H J K Heater (optional) A (mm) H Fd G 26 41 52 70 83 Fn 40 55 75 87 114 D 1 2 2 3 3 C 48 66 79 100 117 B 123 170 183 217 256 A 50 65 70 88 90 E J 16 20 20 20 20 K 6.5 14 16.5 18.5 26.5 Model XLD
(Nominal size) Port size Hydraulic fluid Material 04 06 08 10 12 16 20 24 28 32 04 06 08 10 12 16 20 24 28 32 AL-128H AL-129H AL-131H AL-132H AL-134H AL-135H AL-136H AL-137H KA00813 (V120) AL-128H-V AL-129H-V AL-131H-V AL-132H-V AL-134H-V AL-135H-V AL-136H-V AL-137H-V KA00728 (V120) KA00815 (V85) KA00812 (V100) KA00813 (V120) KA00814 (V150) KA01800 (V175) KA00731 (V85) KA00727 (V100) KA00728
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1
{Rc3/4} FGH200-06 {Rc3/4} FGH300-06 {Rc3/4} 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) 0.01 0.01 0.01 0.005 0.005 0.005 0.001 10 30 50 70 100 0.001 10 30 50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-10 {Rc1} FGH200-10 {Rc1} FGH300-10 {Rc1} 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure drop (
Component module KBC1 KBC2 KBC3 KBC4 KBP1 KBP2 KBP3 KBP4 KBV2-06 2 KBE2-06 2 KBN2 1 KBN2 KBV1-06 KBE2-06 KBV2-06 5 Bracket: KBX(Page 87) Component module KB X 6 KBV2-06 1 KBV1-06 1 KBR2-1 1 KBH2-R2S 1 KBP1 1 KBP1 KBR2-1 Applicable thread size KBH2-R2R KBV2-06 KBP1 Type Bracket: KBX KBV1-06 Part No.
AM550-06, 10 P. 14-20-16 Mist separator 35 dB or more of noise reduction AMC310-03 AMC510-06 AMC610-10 Exhaust cleaner VBA2200-03 Air operated type VBAT05 (5 l, Directly connected to booster regulator) VBAT20 (20 l, Directly connected to booster regulator) VBAT38 (38 l, Directly connected to booster regulator) JIS Symbol Air tank VBAT10 (10 l, Directly connected to booster regulator) Handle